GlideSlope localizer
Quiz von , erstellt am more than 1 year ago

B737-678 PNEUMATIC

440
0
0
GlideSlope localizer
Erstellt von GlideSlope localizer vor fast 4 Jahre
Schließen

PNEUMATIC VAKIFBANK

Frage 1 von 110

1

During a master caution light recall the right pack light illuminates?

Wähle eine der folgenden:

  • Indicating a failure of other the primary or standby pack control

  • Indication the right air conditioning pack is in high flow

  • Indicating the left pack has been selected off and right pack may overloaded

Erklärung

Frage 2 von 110

1

The off sched descent light illuminates if...?

Wähle eine der folgenden:

  • The aircraft has climbed selected flight altitude

  • The aircraft has descended before reaching selected flight altitude

  • The aircraft climbed above the selected flight altitude

Erklärung

Frage 3 von 110

1

The maximum differential pressure for positive relief valve operation is

Wähle eine der folgenden:

  • 8,95 PSI

  • 8,15 PSI

  • 8 PSI

Erklärung

Frage 4 von 110

1

Right pack and zone controller consist of a?

Wähle eine der folgenden:

  • Primary and standby controller for its respective pack

  • Primary controller on

  • Primary controller for its pack and standby controller for the other pack

Erklärung

Frage 5 von 110

1

İn case of clogging in water seperator in 737-700?

Wähle eine der folgenden:

  • İndicator disc on the water seperator is in red range

  • Pack light amber illuminates

  • Duct overheat light amber illuminates

Erklärung

Frage 6 von 110

1

The purpose of the trim air pressure regulating valve is?

Wähle eine der folgenden:

  • to provide fine adjustment of temperature of cabin zones

  • to regulate the hot air pressure 4 PSI more than the cabin pressure

  • to regulate the mass of air flow at the inlet packs

Erklärung

Frage 7 von 110

1

What are the conditions for e&e cooling fans operation?

Wähle eine der folgenden:

  • The respective equipment cooling switch is in the supply/alternate position

  • The recirculation fan switch must be in the OFF position pack high flow

  • Both of pack switches must be off position the recirculation fan switch AUTO

Erklärung

Frage 8 von 110

1

In Boeing 737-600-700 aircrafts the right pack discharge overheat switch is located in?

Wähle eine der folgenden:

  • E&e compartment

  • Distribution manifold in the cabin

  • Air condition mix bay

Erklärung

Frage 9 von 110

1

Boş

Wähle eine der folgenden:

  • Boş

  • Boşş

  • Boşşş

Erklärung

Frage 10 von 110

1

The forward cargo compartment is warmed?

Wähle eine der folgenden:

  • Only when the main outflow valve fully o..

  • At any time when more than 1 PSI difference pressure exist

  • In flight when more than 2,5 PSI difference

Erklärung

Frage 11 von 110

1

In auto pressurisation mode the cabin difference pressure for the off?

Wähle eine der folgenden:

  • 0,10 PSI

  • 0,25 PSI

  • 0,125 PSI

Erklärung

Frage 12 von 110

1

The pressurization system controls airplane with?

Wähle eine der folgenden:

  • A control panel, two cabin pressure control and two outflow valves

  • A control panel two cabin pressure control and one outflow valves

  • A control panel one cabin pressure control and one outflow valve

Erklärung

Frage 13 von 110

1

Why does the DUAL BLEED light illuminate?

Wähle eine der folgenden:

  • When the APU Bleed valve is closed and the Engine bleed switches On

  • When the APU Bleed valve is open and the Engine bleed switches On

  • When the APU Bleed valve is closed and Engine bleed switches Off

Erklärung

Frage 14 von 110

1

If an OFF SCHED DESCENT light comes on the pressurization system will

Wähle eine der folgenden:

  • Pressure the cabin back to the take-off airport altitude

  • Return the cabin to the last cruise altitude

  • Reschedule pressurization rate of change

Erklärung

Frage 15 von 110

1

The FWD DOOR area heater is located in the ?

Wähle eine der folgenden:

  • On the left outboard side of the nose wheel well

  • Right side of the FWD cargo compartment

  • On the right inboard side of the nose wheel well

Erklärung

Frage 16 von 110

1

The bleed air duct pressure indicator?

Wähle eine der folgenden:

  • Requires AC power for operation

  • Operates only when the CDU operating

  • İndicates both temperature and pressure in the duct

Erklärung

Frage 17 von 110

1

When using the pneumatic air CENT the battery switch?

Wähle eine der folgenden:

  • Must be on and air conditioning pack sw on

  • Must be on or off when using aircraft air conditioning

  • Must be on a d air conditioning pack switches off

Erklärung

Frage 18 von 110

1

Where is the receptacle for external compressed air?

Wähle eine der folgenden:

  • Lower left side of the fuselage

  • Upper right side of the fuselage

  • Lower right side of the fuselage

Erklärung

Frage 19 von 110

1

The TRIP RESET switch on the -800-900 airconditioning panel will reset the?

Wähle eine der folgenden:

  • BLEED TRIP OFF, DUCT OVERHEAT and ZONE TEMP lights provided the fault condition has been corrected.

  • DUCT OVERHEAT, PACK and ZONE TEMP lights provided the fault condition has been corrected

  • BLEED TRIP OFF, PACK, ZONE TEMP lights provided the fault condition has been corrected

Erklärung

Frage 20 von 110

1

What input required of the pilot for pressurization auto control system to function property?

Wähle eine der folgenden:

  • Cruise altitude and landing altitudfe

  • Cruise altitude and take-off altitude

  • Landing altitude only

Erklärung

Frage 21 von 110

1

After the overheat lights illuminated during OVERHEAT test?

Wähle eine der folgenden:

  • Action is required as the resetting of the system on the window heat computer

  • No action is required as the resetting of system automatic

  • The window heat switches must be momentraily positioned to off to rest the system

Erklärung

Frage 22 von 110

1

When one air conditioning pack switch selected to HIGH?

Wähle eine der folgenden:

  • Related pack will regulate to LOW FLOW with flap extend

  • Flap selection has no effect on the low flow rate of that pack

  • The operating pack will regulate to high flow only with flaps up

Erklärung

Frage 23 von 110

1

If the external pressure exceeds the internal pressure the ... will open?

Wähle eine der folgenden:

  • Overboard exhaust valve

  • Negative pressure relief valve

  • Positive pressure relief valve

Erklärung

Frage 24 von 110

1

The CONT CAB amber ZONE TEMP light illuminate with recall indicates?

Wähle eine der folgenden:

  • Primary or Standby pac controller failure

  • Primary pack controller failure

  • Primary and stanby pack controller failure

Erklärung

Frage 25 von 110

1

The APU will switch into a HIGH FLOW rate then?

Wähle eine der folgenden:

  • The flaps are down

  • Both engine bleed air switches are selected OFF regardless of flap position

  • The airplane is on ground

Erklärung

Frage 26 von 110

1

When the Rİght Pack switch OFF and the isolation valve switch is in AUTO, the isolation valve will?

Wähle eine der folgenden:

  • Open

  • Closed

  • Modulate

Erklärung

Frage 27 von 110

1

The RH Pack/Zone Temperature controller?

Wähle eine der folgenden:

  • Controls the flight deck and provides back up control for the aft cabin

  • Controls the flight deck and fwd cabin

  • Controls the fwd cabin and provides backup control for the flight deck

Erklärung

Frage 28 von 110

1

Burnination of the amber Bleed Trip Off light indicates ... has automatically closed?

Wähle eine der folgenden:

  • Pressure REgulating and Shut Off valve

  • Isolation valve

  • Apu bleed valve

Erklärung

Frage 29 von 110

1

The lh pack zone temperature controller?

Wähle eine der folgenden:

  • Controls the FWD cabin and provides backup control for the aft cabin

  • Controls the FWD cabin and provides backup control for the flight deck

  • Controls the AFT cabin and provides back up control for the flight deck

Erklärung

Frage 30 von 110

1

Trim Air Modulating Valves are controlled by?

Wähle eine der folgenden:

  • The pressure controllers for the fine adjustment of temperature

  • The pack controllers for the basic temperature regulation

  • Two pack zone controllers for thefine adjustment of temperature

Erklärung

Frage 31 von 110

1

With one air conditioning pack sitch selected to high?

Wähle eine der folgenden:

  • The pack will regulate to LOW FLOW with flap extended

  • Flap sekection has ne effect on the flow rate of that pack

  • The operating pack will reguate o HIGH FLOW only with glaps up

Erklärung

Frage 32 von 110

1

In 737-700 series aircraft the air mix valve?

Wähle eine der folgenden:

  • Pneumatically controlled

  • Electrically operated

  • Pneumatically operated, electrically controlled

Erklärung

Frage 33 von 110

1

When the PACK TRIP OFF (amber) light illuminates in 737-700 aircraft?

Wähle eine der folgenden:

  • THe hot butterfly of airmix valve opens automatically

  • Flow control and shut off valve closes automatically

  • Low limit valve closes automatically

Erklärung

Frage 34 von 110

1

In 737-600/700 rh pack discharge overheat switch is located in

Wähle eine der folgenden:

  • E/E compartment

  • Distribution manifold in the cabin

  • Air condition mix bay

Erklärung

Frage 35 von 110

1

If the AMBER AUTO FAIL light illuminates on the pressurization panel?

Wähle eine der folgenden:

  • Positioning the Pressure Mode Selector to alternate will extinguish the AUTO FAIL light

  • It will automatically extinguis when the pressurization controllers reverts the alternate mode

  • Positioning the Pressurization mode selector to alternate will have no effect on the AUTO FAIL light

Erklärung

Frage 36 von 110

1

The OUT FLOW valve has ?

Wähle eine der folgenden:

  • Two motores each controlled by a decide cabin pressure controllers

  • Three motors controlled by a CPC

  • Three motors, two automatically one manually controlled

Erklärung

Frage 37 von 110

1

Which of the following overheat switches or overtemperature sensors detect and overheat condition when a pack light illuminates?

Wähle eine der folgenden:

  • Compressor discharge overheat switch,ü turbin inlet overheat switch 190F/88c duct overheat switch or duct limit sensor

  • Compressor discharge overheat switch, turbine inlet overheat switch 190f/88c duct overheat switch

  • Compressor discharge overheat switch, turbine inlet overheat switch or pack discharge overheat switch

Erklärung

Frage 38 von 110

1

The PITOT PROBE HEATERS lights are?

Wähle eine der folgenden:

  • Amber in color and associated with the system

  • Not associated with the Master Caution

  • Illuminated when heat is being supplied pitot static and probe heaters

Erklärung

Frage 39 von 110

1

The High Stage Modulating and Shut Off valve?

Wähle eine der folgenden:

  • Is opened at all times irrespective of 5th stage air pressure output

  • Will open if the 5th stage air pressure is insufficent

  • will open if the APU bleed air pressure is insufficient

Erklärung

Frage 40 von 110

1

Standby temperature control valve is ?

Wähle eine der folgenden:

  • Fully controlled PACK/ZONE controller

  • Electrically controlled and operated

  • Either electrically controlled or pneumatically controlled

Erklärung

Frage 41 von 110

1

Where is the flight compartment 190F/88c duct overheat switch located? (600-700)

Wähle eine der folgenden:

  • Distribution compartment

  • E/E compartment

  • LH airconditioning compartment

Erklärung

Frage 42 von 110

1

The cowl ANTI-ICE light is?

Wähle eine der folgenden:

  • Amber in clour indicating over temp or over pressure

  • Blue colur and when illuminated indicates the engine cowl anti-ice valve is in disagreement with the engine anti-ice switch

  • Amber in colour indicating overpressure only

Erklärung

Frage 43 von 110

1

For 800/900 what controls the operating of the temperature control system

Wähle eine der folgenden:

  • The cabin temperature controller only

  • The temperature controller panel and air conditioning bleed air control panel

  • The temperature control panel , the ACAU and PACK/ZONE Temperature Controller

Erklärung

Frage 44 von 110

1

The maximum external air pressure (ground cart)

Wähle eine der folgenden:

  • 30 PSI (at 231C)

  • 40 PSI (at 231C)

  • 60 PSI (at 231C)

Erklärung

Frage 45 von 110

1

A pack Lİght illuminates in flight (without recall)

Wähle eine der folgenden:

  • The standby pack has failed but the primary control is operational

  • The primary pack has failed but the standby control is operational

  • Both primary and standby pack controls have failed.

Erklärung

Frage 46 von 110

1

An engine Bleed Trip OFF light will illuminate

Wähle eine der folgenden:

  • When engine bleed air temperature or pressure exceeds a predetermined limit

  • Only if engine bleed air pressure exceeds a predetermined limit

  • Only if engine bleed air temperature exceeds a predetermined limit

Erklärung

Frage 47 von 110

1

The wing Anti-ice control valve_

Wähle eine der folgenden:

  • are DC motor operated

  • are AC motor operated

  • are pneumatically operated

Erklärung

Frage 48 von 110

1

With ISOLATION VALVE switch AUTO both ENG BLEED sw ON and BOTH Air Cond Pack sw selected AUTO or HIGH?

Wähle eine der folgenden:

  • The ISOLATION VAlVE will be closed

  • The ISOLATION VAlVE will be opened

  • The ISOLATION VAlVE will be closed when the flaps are extend

Erklärung

Frage 49 von 110

1

If the ACM compressor discharge overheat switch activated this?

Wähle eine der folgenden:

  • Commands the RAM AIR system full close

  • Close the PACK FLOW CONT SOV and PACK light on

  • Causes the pack to go to a HIGH FLOW mode of operation

Erklärung

Frage 50 von 110

1

THe total air temperature probe

Wähle eine der folgenden:

  • Does not required heating

  • Its electrically heated

  • It is not heated while on ground

Erklärung

Frage 51 von 110

1

When the pack discharge reaches 250f/121c (overheat) to reset the Air Conditioner sys?

Wähle eine der folgenden:

  • Push the P5 trip reset switch

  • Select the pack switch to HIGH or AUTO

  • Reset is automatic

Erklärung

Frage 52 von 110

1

When you use the wing theamal anti-icing system on the ground?

Wähle eine der folgenden:

  • De-icing fluids are not necessary

  • There is no protection to prevent heating leading edge overheat conditions

  • THe WTAI selenoid bleeds control pressure from the Precooler Control Valve

Erklärung

Frage 53 von 110

1

Which is feed into WTAI?

Pneumatic system

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 54 von 110

1

Pack'lerin AUTO dan HİGH a geçmesi için?

Flaps up

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 55 von 110

1

Duct temp 88C ?

Zone TEMP

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 56 von 110

1

PRSOV closes when?

Pressure is 220 PSI

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 57 von 110

1

Ground cart supply pressure?

60 PSI

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 58 von 110

1

Isolation valve operate?

AC

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 59 von 110

1

Compressor 9th stage?

High pressure

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 60 von 110

1

E/E ventilation?

Equipment ventilation (cooling)

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 61 von 110

1

Wiper how does operate?

With knob rotary

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 62 von 110

1

Cabin altitude aural warning when?

10.000 feet

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 63 von 110

1

Air comes to precooler where?

Fan

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 64 von 110

1

ANTI-ICE Heater test?

HEATER sw ON

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 65 von 110

1

Pack switch positions?

OFF-AUTO-HIGH

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 66 von 110

1

Outflow valve manual controls?

OPEN-CLOSE

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 67 von 110

1

Positive pressure relief valve?

8,95 PSI

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 68 von 110

1

What is the PACKs purposes?

Basic temperature

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 69 von 110

1

ACAU?

2 ea

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 70 von 110

1

Window heater?

Interchangable

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 71 von 110

1

OFF SCHED DESCENT LIGHT?

Take off airport altitude

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 72 von 110

1

PITOT heats?

115v ac

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 73 von 110

1

RAM AIR actuator?

115v ac

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 74 von 110

1

Wing thermal Anti Ice?

Thrust levers more than 60 degree system doesnt operate. Wing Anti Ice ground thermal on switch iki kanat valflerini de kapatır.

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 75 von 110

1

9th stage 110 PSI ?

High stage fully close

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 76 von 110

1

490 F (254 C) ?

PRSOV close

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 77 von 110

1

Flow control and Shut off valve ?

Selenoid A= APU/HIGH flow operation
Selenoid B= LOW and HIGH flow
Selenoid C= Open close valve

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 78 von 110

1

Isolation valve position?

Auto-Close

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 79 von 110

1

Cocpit air?

LH PACK

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 80 von 110

1

TAI ?

Shows N! indicator- Green

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 81 von 110

1

Duct pressure indicator?

P5 panel

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 82 von 110

1

PACK light?

ACAU

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 83 von 110

1

Positive relief valve?

Pneumatic

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 84 von 110

1

Recirculation fan?

115v 3 phase

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 85 von 110

1

Duct temp 88 üstü?

ZONE TEMP light

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 86 von 110

1

LOW LIMIT sensor?

Equipment cooling supply and exhaust

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 87 von 110

1

Packler AUTO da bir Pack HIGH a geçmesi için?

Flaps up

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 88 von 110

1

737-600-700 duct temp 88 C?

DUCT OVHT light

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 89 von 110

1

737-800/900 DUCT TEMP 88C ?

ZONE TEMP light

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 90 von 110

1

Compressor çıkış sıcaklığı 199 C?

Pack light yanar

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 91 von 110

1

PRSOV ne zaman kapalıya gider?

Basınç 220 PSI

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 92 von 110

1

TAI amber light N1?

Valve position not agree more than 8 second

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 93 von 110

1

Cowl Anti-Ice amber light?

Overpressure only

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 94 von 110

1

Cabin altitude pressure switch?

Cabin altitude reached 10000

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 95 von 110

1

Precooler sensor nerede?

ENG Strut Duct

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 96 von 110

1

Ground thermal WTAI Sensor?

Downstream of WTAI

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 97 von 110

1

Door heating system?

-Any pack on
-Arcraft on air

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 98 von 110

1

Heat exchanger blokage?

RAM DOOR FULL OPEN blue light on

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 99 von 110

1

Duct pressure transmitter?

Air cond bay

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 100 von 110

1

Flight Compartment?

LH PACK

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 101 von 110

1

During ENG start?

PRSOV close

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 102 von 110

1

Cargo blowout panels?

1 PSI differenatial pressure

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 103 von 110

1

TRIP RESET?

-ZONE TEMP
-BLEED TRIP OFF
-PACK

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 104 von 110

1

Overheat Switches?

-comp. discharge
-turbine inlet switch
-pack discharge

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 105 von 110

1

Trim Air Regulating Shut Off valve?

+4 PSI Cabin air

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 106 von 110

1

Recirculation system?

Fuel save

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 107 von 110

1

Recirculation fans?

Ground= LH Recirc. FAN BOTH PACK HIGH FLOW iken çalışmaz diğer tüm şartlarda yerde çalışır.
RH Recirc. FAN yerde her zaman çalışır

Air= LH Recirc. FAN herhangi PACK HIGH da ise çalışmaz
RH Recirc. FAN iki PACK HIGH ise çalışmaz

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 108 von 110

1

-600/700 Aircodition?

1 CTC
1 ACAU
1 CONTROL PANEL

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 109 von 110

1

RH PACK ZONE CONTROLLER?

-Flight compartment
-FWD pass. cabin

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung

Frage 110 von 110

1

NGS Shut Off valve?

Center Tank Re-Fuel Valve closed

Wähle eins der folgenden:

  • WAHR
  • FALSCH

Erklärung