PLC Chapter 1-4 Part 1

Beschreibung

College PLC 301 Quiz am PLC Chapter 1-4 Part 1, erstellt von second_second101 am 01/10/2015.
second_second101
Quiz von second_second101, aktualisiert more than 1 year ago
second_second101
Erstellt von second_second101 vor mehr als 9 Jahre
21
0
1 2 3 4 5 (0)

Zusammenfassung der Ressource

Frage 1

Frage
Select the main functions of a PLC
Antworten
  • Replacing Relay Logic
  • Replacing programmable logic
  • Timing
  • Processing digital signals
  • Processing analog signals
  • Saving energy compared to relay
  • Comparing
  • Counting
  • Calculating

Frage 2

Frage
The structure of a PLC isn't based on any other electronic; their design is unique to themselves.
Antworten
  • True
  • False

Frage 3

Frage
A PLC eliminates the mess of hardwiring that relay controls require
Antworten
  • True
  • False

Frage 4

Frage
Which function control responds faster to data.
Antworten
  • Programmable Logic Control
  • Relay Logic Control

Frage 5

Frage
The PLC has a [blank_start]_____[blank_end] cost compared to relay logic controls.
Antworten
  • lower

Frage 6

Frage
If an application requires more than a [blank_start]half-dozen[blank_end] of control relays, a PLC will probably be more cost effective
Antworten
  • half dozen

Frage 7

Frage
Communications Capability - A PLC can communicte with other computer based systems to perform functions such as supervisory [blank_start]control[blank_end], data [blank_start]gathering[blank_end], [blank_start]monitoring[blank_end] devices and process parameters, and [blank_start]download[blank_end] and upload of programs
Antworten
  • download
  • gathering
  • monitoring
  • control

Frage 8

Frage
PLCs are easier to trouble shoot thanks to built-in [blank_start]resident diagostics[blank_end] and [blank_start]override[blank_end] functions
Antworten
  • resident diagostics
  • override

Frage 9

Frage
The term architecture can refer to:
Antworten
  • PLC hardware
  • PLC software
  • A combination of both
  • None the given answers
  • PLC hardware, PLC software, or to a combination of both.

Frage 10

Frage
An [blank_start]open architecture[blank_end] design allows the system to be connected [blank_start]easily[blank_end] to [blank_start]devices[blank_end] and programs made by other manufacturers.
Antworten
  • open architecture
  • easily
  • devices

Frage 11

Frage
A system with a [blank_start]closed architecture[blank_end], is one whos [blank_start]design[blank_end] is proprietary, making it more difficult to [blank_start]connect[blank_end] to other systems
Antworten
  • closed architecture
  • design
  • connect

Frage 12

Frage
A [blank_start]fixed[blank_end] I/O is typical of small PLC's that come in one package with no separate, removable units. The processor and I/O are packaged [blank_start]together[blank_end].
Antworten
  • fixed
  • together

Frage 13

Frage
[blank_start]Modular[blank_end] I/O is divided by compartments into which separate modules can be plugged. This feature [blank_start]greatly[blank_end] increases youor options and the unit's flexibility.
Antworten
  • Modular
  • greatly

Frage 14

Frage
The power supply provides [blank_start]DC[blank_end] power to all modules that plug into the [blank_start]rack[blank_end]. For large PLC systems, this power supply [blank_start]does not[blank_end] normally supply power to the field devices.
Antworten
  • DC
  • rack
  • does not

Frage 15

Frage
The [blank_start]CPU[blank_end] consists of a [blank_start]microprocessor[blank_end] for implementing the [blank_start]logic[blank_end] and [blank_start]controlling[blank_end] the communications among the modules.
Antworten
  • microprocessor
  • CPU
  • logic
  • controlling
  • processing

Frage 16

Frage
The processor requires [blank_start]memory[blank_end] for storing the results of the [blank_start]logical[blank_end] operations performed by the microprocessor as well as the operating system and the PLC program.
Antworten
  • memory
  • logical

Frage 17

Frage
What is an I/O system?
Antworten
  • A system with a closed architecture, is one whos design is proprietary, making it more difficult to connect to other systems
  • An open architecture design allows the system to be connected easily to devices and programs made by other manufacturers.
  • I/O system forms the interface by which field devices are connected to the controller.
  • A programming device is used to enter the desired program into the memory of the processor. The program can be entered using relay ladder logic which is one of the most popular programming languages.

Frage 18

Frage
Input devices are hardwired to [blank_start]Input terminals[blank_end]
Antworten
  • Input terminals

Frage 19

Frage
Examples of input devices include:
Antworten
  • Push buttons
  • Limit switches
  • Mice
  • Keyboard
  • Sensors

Frage 20

Frage
Examples of Output devices include:
Antworten
  • Small Motors
  • Motor Starters
  • Large Motors
  • Spindle
  • Solenoid Valves

Frage 21

Frage
In order to isolate internal components from the input and output terminals, PLCs often employ an [blank_start]optical isolator[blank_end], which uses light to coupe the circuits
Antworten
  • optical isolator

Frage 22

Frage
External devices are referred to as [blank_start]field devices[blank_end] or [blank_start]Real-world[blank_end] devices
Antworten
  • field devices
  • Real world

Frage 23

Frage
A programming device is used to enter the desired program into the [blank_start]memory[blank_end] of the processor. The program can be entered using [blank_start]relay ladder logic[blank_end] which is one of the [blank_start]most popular[blank_end] programming languages.
Antworten
  • relay ladder logic
  • most popular
  • memory

Frage 24

Frage
A programming language that instead of using letters, ladder logic programming uses symbols to show their intended outcome.
Antworten
  • True
  • False

Frage 25

Frage
A program in ladder logic isn't similar to a schematic for a relay control circuit.
Antworten
  • True
  • False

Frage 26

Frage
Name the most popular programming device for a PLC
Antworten
  • A Computer
  • A Dedicated Programming Device
  • A Gameboy

Frage 27

Frage
A program is a user developed set of [blank_start]instructions[blank_end] for the PLC to [blank_start]execute[blank_end].
Antworten
  • instructions
  • execute

Frage 28

Frage
What input device is this?
Antworten
  • Solenoid
  • Push Button
  • Temperature Switch
  • Motor Starter Coil

Frage 29

Frage
What is the purpose of each value in a Rack/Slot address?
Antworten
  • File Type
  • File Number
  • File Delimiter
  • File Delimiter
  • File No.
  • File Type
  • File Type
  • File No.
  • File Delimiter
  • Rack No.
  • Group no.
  • File Delimiter
  • Rack No.
  • Group No.
  • Terminal Number
  • File Delimiter
  • Bit Delimiter
  • Bit Address
  • Terminal Number
  • File Number
  • Group Number

Frage 30

Frage
An input interface module [blank_start]accepts[blank_end] signals from the machine or process devices and convert them into signals that can be used by the controller
Antworten
  • accepts
  • converts
  • reverts

Frage 31

Frage
An output interface device [blank_start]converts[blank_end] controller signals into external signals used to control the machine or the process
Antworten
  • converts

Frage 32

Frage
The hardware assembly which houses the I/O modules, processor modules, and power supplies is called a [blank_start]chassis[blank_end]
Antworten
  • chassis

Frage 33

Frage
An addressable unit consisting of 128 input points and 128 output points is called a [blank_start]logical rack[blank_end]
Antworten
  • logical rack

Frage 34

Frage
What kind of module does a remote I/O use to communicate with the processor module?
Antworten
  • Communication Module
  • Email Module
  • Breakfast
  • Rope and Cups

Frage 35

Frage
Which of the following programmable logic controlers uses a Rack/Slot based addressing scheme?
Antworten
  • Allen-Bradley PLC-5
  • SLC 50
  • Allen-Bradley ControlLogix
  • SLC 60
  • STC 50
  • Allen-Bradley PLC 60

Frage 36

Frage
Which of the following PLCs use a tag based addressing scheme?
Antworten
  • SLC 50
  • SLC 60
  • SLC 70
  • SLC 40
  • Allen-Bradley ControlLogix
  • SLC ControlLogix

Frage 37

Frage
The most common I/O interface is the ___ type.
Antworten
  • Discrete
  • Analog
  • Loud
  • Digital

Frage 38

Frage
A discrete I/O interface connects field input devices of the ON/OFF nature such as selector switches,
Antworten
  • True
  • False

Frage 39

Frage
The classification of discrete I/O covers bit oriented inputs and outputs.
Antworten
  • True
  • False

Frage 40

Frage
Each [blank_start]discrete[blank_end] I/O module is powered by some field supplied voltage source
Antworten
  • discrete

Frage 41

Frage
Discrete I/O modules receive power from the:
Antworten
  • backplane through the PLC module power supply
  • backplane through the CPU module power supply
  • backplane through the communication module power supply

Frage 42

Frage
A switch that opens and closes a circuit either electromechanically, or electronically is called a [blank_start]relay[blank_end]
Antworten
  • relay

Frage 43

Frage
Individual AC outputs are usually limited by the size of the triac to
Antworten
  • 1A or 2A
  • 2A or 3A
  • 1A or 4A

Frage 44

Frage
An [blank_start]optical Isolator[blank_end] is used to provde electrical isolation between the power and logic circuitry
Antworten
  • optical Isolator

Frage 45

Frage
Certain DC I/O modules specify whether the module is designed for interfacing with current-source or current-sink devices.
Antworten
  • True
  • False

Frage 46

Frage
A sinking digital I/O (input/output) provides a [blank_start]grounded[blank_end] connection to the load
Antworten
  • grounded

Frage 47

Frage
A sourcing digital I/O provides a [blank_start]voltage[blank_end] source to the load
Antworten
  • voltage

Frage 48

Frage
If the module is current-source, then the input or output device must be [blank_start]current-sinking[blank_end]
Antworten
  • current-sinking

Frage 49

Frage
Analog input and output devices have how many possible number of values?
Antworten
  • Infinite
  • 2
  • 3
  • 6
  • 5
  • 7

Frage 50

Frage
Typical analog inputs and outputs vary from:
Antworten
  • 0 to 20 milliamps
  • 4 to 20 milliamps
  • 0 to 10 volts
  • 0 to 10 milliamps
  • 4 to 20 volts

Frage 51

Frage
The two basic type of analog input modules are [blank_start]voltage[blank_end] sensing and current sensing.
Antworten
  • voltage

Frage 52

Frage
The main element of the analog input module is an analog to digital (A/D) converter
Antworten
  • True
  • False

Frage 53

Frage
[blank_start]Bipolar[blank_end] input modules can accept signals that swing between a negative and positive value.
Antworten
  • Bipolar

Frage 54

Frage
[blank_start]Unipolar[blank_end] input modules can accept an input signal that varies in the positive direction only.
Antworten
  • Unipolar

Frage 55

Frage
[blank_start]Resolution[blank_end] refers to the smallest change in input signal value that can be sensed
Antworten
  • Resolution
Zusammenfassung anzeigen Zusammenfassung ausblenden

0 Kommentare

There are no comments, be the first and leave one below:

ähnlicher Inhalt

PLC- Exam pack. (UK-LAW)
Bored Pidgeon
Introducción Al PLC
LUIS ALEJANDRO VAZQUEZ SASTRE
Hannibal Ancient History PLC
James McConaghy
Topic 2 : PLC Key Terms
Dawn S_akura
Wärmelehre Teil 1
Peter Kasebacher
Deutsch-Abitur-Basiswissen für Gedichts- & Lektürenvergleich
danastone
B1 Adjektivdeklination
Anna Kania
Vetie - Pharma 2017
Fioras Hu
Vetie Geflügel 2017
Johanna Müller
Vetie - Spezielle Pathologie 2016
Birte Schulz