PPD Quiz IX

Beschreibung

ARCH PPD Quiz am PPD Quiz IX, erstellt von M. A. am 15/12/2022.
M. A.
Quiz von M. A., aktualisiert more than 1 year ago
M. A.
Erstellt von M. A. vor etwa 3 Jahre
1
0

Zusammenfassung der Ressource

Frage 1

Frage
What is the main disadvantage of the single duct, constant air volume HVAC systems?
Antworten
  • They do not provide uniform loads
  • They don't provide individual temperature control in spaces therefore, not preferred in buildings with smaller units, such as hotels.
  • They are not very economical to operate and install.
  • They are very noisy applications and not recommended where sound isolation is a primary concern

Frage 2

Frage
Which one below defines the bands of vegetation that flank a channel or lake?
Antworten
  • Buffer Zones
  • Flood Plains
  • Levees
  • Riparian Corridors

Frage 3

Frage
Insert the missing information in the boxes given below regarding the concrete’s structural capacity. Concrete by itself is inherently strong in [blank_start]__[blank_end] and weak in [blank_start]__[blank_end] .
Antworten
  • compression
  • tension

Frage 4

Frage
An office building will be built in a seismically active location. The ground studies of the location show that the period of the ground is 1 second. Based on this information, which of the following number of floors would cause the greatest damage to the building during a possible earthquake?
Antworten
  • 5 floors
  • 10 floors
  • 15 floors
  • 20 floors

Frage 5

Frage
What is the name of the machine that is used for lumber surfacing?
Antworten
  • Planing
  • Kiln
  • Saw Blades
  • Surfacing

Frage 6

Frage
Which of the following reasons for the selection of the given steel structural member is primarily cost driven?
Antworten
  • Selecting the lightest beam possible that will provide required spanning
  • Selecting custom built steel sections for beams
  • Specifying beams that has the highest weight per linear feet
  • Specifying only field- welded connections through out the entire structure, where connection of two steel members are necessary

Frage 7

Frage
For light to medium loaded and short span structures, which of the site-cast concrete framing systems below should be selected? Check the two that apply.
Antworten
  • One-Way Solid Slab
  • Waffle Slab
  • One-Way Beam and Slab
  • Two-Way Flat Plate
  • Two-Way Flat Slab

Frage 8

Frage
An architect is deciding on the boiler type for a new school project. The main concern of the school board is to provide the most energy efficient HVAC system possible for the school building. Which of the following boiler type (for HVAC systems) is probably the best fit for this project, simply because it conserves energy the most?
Antworten
  • Steam Boilers
  • Modular Boilers
  • Compact Boilers
  • Electric Boilers

Frage 9

Frage
Select all of the correct heat island effect mitigation strategies Check the three that apply.
Antworten
  • Specifying ballasted EPDM roof cover with low albedo gravel.
  • Designing green roofs
  • Resurface existing impervious parking lot surfaces with ultra-thin white-topping concrete
  • Using impervious paving materials
  • Utilizing urban design tools to create effective shading areas

Frage 10

Frage
An architect is designing a house where the main driving force of the design is utilizing as many passive heating and cooling strategies as possible. The architect informs the client about the importance of heat retention in such designs and recommends using super-insulation as opposed to regular insulation in exterior walls. Which of the following negative side-effect of using super insulation in buildings should be mentioned to the client immediately to prevent any future issues?
Antworten
  • Increased gross area of the exterior walls due to super-insulation
  • More effective moisture migration with super-insulation
  • Increased cost of cooling the space due to super-insulation
  • Increased cost of building due to super-insulation even with the potential elimination of heating/cooling requirement entirely.

Frage 11

Frage
Even though they are good for day-lighting and space ventilation, which of the following issue is associated with the high-windows in spaces?
Antworten
  • Window to wall ratio
  • Effective aperture
  • Glare
  • Visible light transmittance

Frage 12

Frage
Which of the following scenario is the best for using passive chilled beams as part of HVAC system?
Antworten
  • A new office building where cooling, heating and ventilating spaces are required.
  • In the locker rooms of a school building, which includes minimum 20 shower stalls with partial height separators and 20 toilet stalls with similar compartments to showers.
  • To supplement the cooling needs of an existing laboratory building which recently adopted new processes that are sensitive to changes in air pressure and airflow and hired a significant amount of people.
  • A hospital building where existing HVAC system is not enough to meet cooling and ventilation loads and space for new mechanical equipment is limited.

Frage 13

Frage
A fully sprinklered adult-care center with 4 residents has a 12 feet fire separation distance from the adjacent building. The building has a 4600 sf exterior wall area. What is the maximum allowable exterior unprotected opening area in total? https://codes.iccsafe.org/content/IBC2018
Antworten
  • Unlimited
  • 2070 sf
  • 690 sf
  • 3450 sf

Frage 14

Frage
Which one below accurately describes an atrium as per International Building Code 2018? https://codes.iccsafe.org/content/IBC2018
Antworten
  • An opening connecting two or more floor levels that are closed at the top.
  • Main floor area that a mezzanine opens and connects to.
  • A building wrapped around an open space.
  • A series of openings through floors that are enclosed by a shaft, such as an enclosed stair.

Frage 15

Frage
As per International Building Code 2018, what is the maximum distance of travel from any point to an exit in covered malls?
Antworten
  • 75 feet
  • 100 feet
  • 150 feet
  • 200 feet

Frage 16

Frage
What is the minimum fire separation requirements for an incinerator room at a two-story office building without sprinklers? https://codes.iccsafe.org/content/IBC2018
Antworten
  • 1 hr
  • 2 hrs
  • 3 hrs
  • Not permitted unless the building is fully sprinklered.

Frage 17

Frage
Based on the thermal planning principles only, drag & drop the given building functions below across to the locations marked in roman numerals in the bubble diagram of an elementary school building given below. Options Include: • Classrooms • Utilities • Cafeteria & Restrooms • Gymnasium • Administrative Offices https://www.flexiquiz.com/Uploads/Questions/sc3ff7f59-3c5c-40e9-a536-681c941e44c4_qb5a96129-6dd7-4f56-830a-d3e994f25696
Antworten
  • Classrooms
  • Cafeteria & Restrooms
  • Gymnasium
  • Administrative Offices
  • Utilities

Frage 18

Frage
If the simple load bearing beam is in in equilibrium under the given loads as shown in above graphic above, find R2 in kips. (Fill the number in the given box below.) [blank_start]__[blank_end] https://www.flexiquiz.com/Uploads/Questions/sc3ff7f59-3c5c-40e9-a536-681c941e44c4_q3c9b1dcf-07a3-4e46-a958-314e7f9b9dac
Antworten
  • 21.6

Frage 19

Frage
A simple beam has a span of 6 ft and supports a distributed load of 8 kips per foot. If the beam is a W12 x 30, what is the maximum flexural stress at extreme fiber? ( The section modulus of the cross-section is 38.6 in.3) [blank_start]__[blank_end] ksi (Round to the nearest tenth)
Antworten
  • 11.2
Zusammenfassung anzeigen Zusammenfassung ausblenden