6-Testing and troubleshooting

Beschreibung

Class quiz (Class Quiz) Quiz am 6-Testing and troubleshooting, erstellt von Jeanie Fitzgerald am 25/07/2017.
Jeanie Fitzgerald
Quiz von Jeanie Fitzgerald, aktualisiert more than 1 year ago
Jeanie Fitzgerald
Erstellt von Jeanie Fitzgerald vor fast 7 Jahre
61
2

Zusammenfassung der Ressource

Frage 1

Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 1 method
Antworten
  • Specification and visual verification
  • Testing with various equipment as required for each type of cable
  • Documentation

Frage 2

Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 2 method
Antworten
  • Specification and visual verification
  • Testing with various equipment as required for each cable
  • Documentation

Frage 3

Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 3 method
Antworten
  • Specification and visualization
  • Testing with various equipment required per cable
  • Documentation

Frage 4

Frage
Troubleshooting a problem in a customers cabling system involves, Check all that apply
Antworten
  • Verify and isolate the problem
  • repair and retest to ensure functionality
  • alienate or confuse person being questioned

Frage 5

Frage
Troubleshooting is an __________________ process
Antworten
  • tedious
  • investigative
  • technical

Frage 6

Frage
These types of test equipment are used for which of the following, (wire map, multimeter, TDR, butt set, inductive amplifier,...
Antworten
  • optical fiber media
  • copper media

Frage 7

Frage
Certification test sets are used to verify that a cabling system meets transmission performance requirements. These link parameters are defined in which applicable standards. Check all that apply
Antworten
  • ANSI/TIA 1152
  • ISO/IEC 11801
  • NEC/NFPA

Frage 8

Frage
What is the frequency range for Category 6a
Antworten
  • 250 MHz
  • 500 MHz
  • 600 MHz

Frage 9

Frage
Nominal velocity of propagation ( NVP) is used to determine
Antworten
  • length
  • delay skew
  • wire map

Frage 10

Frage
This coefficient is used to determine the speed of transmission along a cable relative to the speed of light in a vacuum, typically expressed as a percentage.
Antworten
  • NVP
  • NEXT
  • ACRF

Frage 11

Frage
Factory calibration may be required every 18 months for certification test sets.
Antworten
  • True
  • False

Frage 12

Frage
A good rule of thumb is to perform the field calibration at least_________ or ______________ a new series of tests. (Check all that apply)
Antworten
  • once a day
  • before beginning
  • monthly

Frage 13

Frage
An *PASS or *FAIL is often referred to as the _________ _________ or a __________ ___________ . Check all that apply
Antworten
  • uncertainty zone
  • marginal condition
  • reference dimension

Frage 14

Frage
Pairs within a 4 pair cable use a different twist length to improve NEXT. A physical difference in length between pairs is referred to as
Antworten
  • velocity of propagation
  • delay skew
  • return loss

Frage 15

Frage
When addressing copper media, __________________ is the loss in power as it travels along a cable, increases with temperature, frequency and cable length as well as improper terminations and equipment cords.
Antworten
  • Excessive near end crosstalk ( NEXT )
  • Attenuation to crosstalk ratio ( ACR )
  • High Insertion loss

Frage 16

Frage
___________ is the unwanted signal coupling between pairs, It is measured at the end of a cable nearest the point of transmission.
Antworten
  • Insertion loss
  • Attenuation to cross talk (ACR)
  • Near end cross talk (NEXT)

Frage 17

Frage
__________________ is a ratio of the outgoing signal to the power of the reflected signal expressed in dB.
Antworten
  • Attenuation
  • delay skew
  • return loss

Frage 18

Frage
Because of the twisting of the pairs, the actual physical length of balanced twisted pair cable will appear slightly shorter than the electrically measured length.
Antworten
  • True
  • False

Frage 19

Frage
Prior to Optical fiber installation, the installer and the client should determine what field tests should be performed to include these as a minimum. Check all that apply
Antworten
  • polarity
  • attenuation
  • length

Frage 20

Frage
Pre-installation testing should start with a check that the fiber type is correct. testing can be done with a visual fault locator(VFL), optical loss test set (OLTS), and an optical time domain reflectometer (OTDR). Of these three, which can be used using only one end
Antworten
  • VFL
  • OLTS
  • OTDR

Frage 21

Frage
Acceptance testing is accomplished by using which of the folowing
Antworten
  • VFL
  • OLTS
  • OTDR

Frage 22

Frage
This tool is used to inspect the end face of the optical fiber connector for radius of curvature, offset of polish and optical height.
Antworten
  • Microscope
  • Interferometer
  • VFL

Frage 23

Frage
Microscopes greater than 200x power, tend to make the smallest defect look much worse than it actually is.
Antworten
  • True
  • False

Frage 24

Frage
For bi-directional testing at both wavelengths at one time the test instrument to be used is
Antworten
  • OLTS
  • OTDR
  • Interferometer

Frage 25

Frage
A current certificate of calibration of the tester may be required as part of the projects documentaion requirements.
Antworten
  • True
  • False

Frage 26

Frage
All values of attenuation for cable, connectors, and splices provided in any standard or specification are stated as being the maximum allowed loss values accepted by the standard.
Antworten
  • True
  • False

Frage 27

Frage
Connector insertion loss is often stated in cabling components standards as _______ dB per mated pair for both multimode and singlemode, but all products should be better than _______ per mated pair.
Antworten
  • 3.5, 1.5
  • 0.75, 0.5
  • 0.5, 0.3

Frage 28

Frage
The splice insertion loss allowance for LAN cabling standards is 0.3 dB per splice regardless if it is mechanical or fusion, single mode or multi mode.
Antworten
  • True
  • False

Frage 29

Frage
Bandwidth for optical fiber circuits cannot be measured in the field or proven through calculations by installer.
Antworten
  • True
  • False

Frage 30

Frage
The _______ jumper method is the preferred referencing method for most installed optical fiber systems.
Antworten
  • two, formerly Method A
  • one, formerly Method B
  • three, formerly Method C

Frage 31

Frage
This tester locates and detects faults and determines the amount of signal loss at any point in the optical fiber.
Antworten
  • OLTS
  • OTDR
  • VFL

Frage 32

Frage
The OTDR trace ___________ replace the need for the OLTS testing.
Antworten
  • does
  • does not

Frage 33

Frage
This tester uses Rayleigh scattering and Fresnel reflection to measure characteristics of an optical fiber.
Antworten
  • OLTS
  • OTDR
  • Interferometer

Frage 34

Frage
_______________ wavelengths of light exhibit greater amounts of attenuation in the same optical fiber because of their higher sensitivity to Rayleigh scattering.
Antworten
  • Longer
  • Shorter

Frage 35

Frage
_____________ wavelengths are more sensitive to bending loss.
Antworten
  • Longer
  • Shorter
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Der menschliche Körper
JohannesK
Englisch Vokabeln (allgemein)
lucas.kok
Physik Formeln
AntonS
Streitstände - Strafecht
myJurazone
Der Erste Weltkrieg
Laura Overhoff
Differenzialrechnung (Analysis) Zusammenfassung
Antonia C
Vertragsrecht - Multiple-Choice-Test
Maximilian Mustermann
Gesundheitspsychologie EC Uni Wien
hans urst
Vetie: Virofragen 2015
Johanna Tr
Vetie Viro 2018
Anna Nie
THEO: VO PSYCH - Medienpsychologie
Adrienne Tschaudi