Frage 1
Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 1 method
Frage 2
Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 2 method
Frage 3
Frage
Testing should be performed using an organized systematic method. Which of the following is Phase 3 method
Frage 4
Frage
Troubleshooting a problem in a customers cabling system involves, Check all that apply
Antworten
-
Verify and isolate the problem
-
repair and retest to ensure functionality
-
alienate or confuse person being questioned
Frage 5
Frage
Troubleshooting is an __________________ process
Antworten
-
tedious
-
investigative
-
technical
Frage 6
Frage
These types of test equipment are used for which of the following, (wire map, multimeter, TDR, butt set, inductive amplifier,...
Antworten
-
optical fiber media
-
copper media
Frage 7
Frage
Certification test sets are used to verify that a cabling system meets transmission performance requirements.
These link parameters are defined in which applicable standards. Check all that apply
Antworten
-
ANSI/TIA 1152
-
ISO/IEC 11801
-
NEC/NFPA
Frage 8
Frage
What is the frequency range for Category 6a
Frage 9
Frage
Nominal velocity of propagation ( NVP) is used to determine
Antworten
-
length
-
delay skew
-
wire map
Frage 10
Frage
This coefficient is used to determine the speed of transmission along a cable relative to the speed of light in a vacuum, typically expressed as a percentage.
Frage 11
Frage
Factory calibration may be required every 18 months for certification test sets.
Frage 12
Frage
A good rule of thumb is to perform the field calibration at least_________ or ______________ a new series of tests. (Check all that apply)
Antworten
-
once a day
-
before beginning
-
monthly
Frage 13
Frage
An *PASS or *FAIL is often referred to as the _________ _________ or a __________ ___________ . Check all that apply
Antworten
-
uncertainty zone
-
marginal condition
-
reference dimension
Frage 14
Frage
Pairs within a 4 pair cable use a different twist length to improve NEXT. A physical difference in length between pairs is referred to as
Antworten
-
velocity of propagation
-
delay skew
-
return loss
Frage 15
Frage
When addressing copper media, __________________ is the loss in power as it travels along a cable, increases with temperature, frequency and cable length as well as improper terminations and equipment cords.
Frage 16
Frage
___________ is the unwanted signal coupling between pairs, It is measured at the end of a cable nearest the point of transmission.
Frage 17
Frage
__________________ is a ratio of the outgoing signal to the power of the reflected signal expressed in dB.
Antworten
-
Attenuation
-
delay skew
-
return loss
Frage 18
Frage
Because of the twisting of the pairs, the actual physical length of balanced twisted pair cable will appear slightly shorter than the electrically measured length.
Frage 19
Frage
Prior to Optical fiber installation, the installer and the client should determine what field tests should be performed to include these as a minimum.
Check all that apply
Antworten
-
polarity
-
attenuation
-
length
Frage 20
Frage
Pre-installation testing should start with a check that the fiber type is correct. testing can be done with a visual fault locator(VFL), optical loss test set (OLTS), and an optical time domain reflectometer (OTDR). Of these three, which can be used using only one end
Frage 21
Frage
Acceptance testing is accomplished by using which of the folowing
Frage 22
Frage
This tool is used to inspect the end face of the optical fiber connector for radius of curvature, offset of polish and optical height.
Antworten
-
Microscope
-
Interferometer
-
VFL
Frage 23
Frage
Microscopes greater than 200x power, tend to make the smallest defect look much worse than it actually is.
Frage 24
Frage
For bi-directional testing at both wavelengths at one time the test instrument to be used is
Frage 25
Frage
A current certificate of calibration of the tester may be required as part of the projects documentaion requirements.
Frage 26
Frage
All values of attenuation for cable, connectors, and splices provided in any standard or specification are stated as being the maximum allowed loss values accepted by the standard.
Frage 27
Frage
Connector insertion loss is often stated in cabling components standards as _______ dB per mated pair for both multimode and singlemode, but all products should be better than _______ per mated pair.
Antworten
-
3.5, 1.5
-
0.75, 0.5
-
0.5, 0.3
Frage 28
Frage
The splice insertion loss allowance for LAN cabling standards is 0.3 dB per splice regardless if it is mechanical or fusion, single mode or multi mode.
Frage 29
Frage
Bandwidth for optical fiber circuits cannot be measured in the field or proven through calculations by installer.
Frage 30
Frage
The _______ jumper method is the preferred referencing method for most installed optical fiber systems.
Antworten
-
two, formerly Method A
-
one, formerly Method B
-
three, formerly Method C
Frage 31
Frage
This tester locates and detects faults and determines the amount of signal loss at any point in the optical fiber.
Frage 32
Frage
The OTDR trace ___________ replace the need for the OLTS testing.
Frage 33
Frage
This tester uses Rayleigh scattering and Fresnel reflection to measure characteristics of an optical fiber.
Frage 34
Frage
_______________ wavelengths of light exhibit greater amounts of attenuation in the same optical fiber because of their higher sensitivity to Rayleigh scattering.
Frage 35
Frage
_____________ wavelengths are more sensitive to bending loss.