Eric Ballard
Quiz by , created more than 1 year ago

Self-Contained Breathing Apparatus

19
0
0
Eric Ballard
Created by Eric Ballard over 9 years ago
Close

SOG Quiz #6

Question 1 of 19

1

SCBA and use shall meet NFPA 1981 2007 ed., Standard on Open-Circuit Self-Contained Breathing Apparatus for firefighters.

Select one of the following:

  • True
  • False

Explanation

Question 2 of 19

1

Per the SCBA SOG, select the appropriate hazards that SCBAs protect the member from breathing

Select one or more of the following:

  • Particulates

  • Products of Combustion

  • Atmospheres that are hazardous, toxic or oxygen deficient

  • Environments that are IDLH

  • Smoke and Odor investigations

  • Possible undected CO environments

  • Confined space incidents

Explanation

Question 3 of 19

1

A written medical clearance shall be obtained before an employee is required to wear a mask that requires a tight fitting face seal, if the member had a positive history outlined in 29 CFR 1910.134.

Select one of the following:

  • True
  • False

Explanation

Question 4 of 19

1

What are the minimum training requirements that a member must complete to wear and use SCBAs?

Select one of the following:

  • 29 CFR 1910.134, NFPA 1404, and any other applicable standards or codes

  • NFPA 1910 only

  • Agency specific maze or SCBA confined space test without pulling mask off

  • Fire academy and stress test

Explanation

Question 5 of 19

1

Per the SCBA SOG, select the situations that require MANDATORY use of SCBA while operating.

Select one or more of the following:

  • Atmosphere that may become contaminated

  • Contaminated atmosphere

  • CO levels are greater then 25 PPM

  • Hydrogen Cyanide levels greater then 4.5 PPM

  • Atmosphere that is oxygen deficient at 19.5% or higher then 23%

  • During overhaul of structure fire

  • Vehicle Fires

  • Inside commercial smoke investigation

Explanation

Question 6 of 19

1

Additional operating conditions that require the use of SCBA include: active fire areas, potentially exlposive gas leaks or fuel spills, visible products of combustion including vehicle and dumpster fires.

Select one of the following:

  • True
  • False

Explanation

Question 7 of 19

1

Select the list of approriate conditions that require SCBA use.

Select one or more of the following:

  • Invisible contaminants suspected including CO or asbestos, where toxic products maybe present, any confined space that has not been tested.

  • When your crew members are experiencing bad gas in the firehouse.

Explanation

Question 8 of 19

1

SCBA use can stop and can be removed after the the fire is deemed out and ventilation has been completed.

Select one of the following:

  • True
  • False

Explanation

Question 9 of 19

1

Air monitoring shall include monitoring for? Select all appropriate hazards.

Select one or more of the following:

  • CO

  • HCN

  • LEL

  • 02%

  • H2S

  • Methane

  • Flammable Gas

Explanation

Question 10 of 19

1

All SMFR truck companies and Haz Mat units carry 4 gas detectors.

Select one of the following:

  • True
  • False

Explanation

Question 11 of 19

1

Strong consideration should be given to continued SCBA use to the completion of overhaul and until all units have exited the structure.

Select one of the following:

  • True
  • False

Explanation

Question 12 of 19

1

The SCBA indicates low air alarm by 2 methods.

Select one of the following:

  • True
  • False

Explanation

Question 13 of 19

1

Select the appropriate heads up display lighting color and air pressure readings.

Select one of the following:

  • 2 Green Full, 1 green 3000, amber 2000, red 1100-1125

  • 2 green full, 1 green 2500, amber 1500, red 1000

  • 2 green 4000, 1 green 3000, amber 2000, red 1125

Explanation

Question 14 of 19

1

When used, the face piece will be worn under the protective hood and proir to plugging in the regulator, a proper seal shall be checked.

Select one of the following:

  • True
  • False

Explanation

Question 15 of 19

1

The full facepiece of SCBA shall constitute face and eye protection when worn. The regulator shall be attached in order to be considered eye and face protection.

Select one of the following:

  • True
  • False

Explanation

Question 16 of 19

1

Which answer is the most true regarding facial hair and face piece seal?

Select one of the following:

  • Goatees and mustaches are allowed as long as face piece seal is adequate

  • No facial hair is permitted that interferes with the face piece seal.

  • Sideburns must not be longer then bottom of ear

  • Facepiece may not seal appropriately if the employee is not properly groomed

Explanation

Question 17 of 19

1

Select the most appropriate considerations to be planned when entering into a contaminated or unknown atmosphere.

Select one or more of the following:

  • Sufficient air to enter

  • Ability to carry out the task required

  • Return to a safe breathing area prior to low air alarm sounding

  • Have a TIC and search rope

  • Start with heads up display on 2 greens and ensure full bottle

Explanation

Question 18 of 19

1

SMFRA has equipped all airpacks with three emergency devices.

Select one of the following:

  • True
  • False

Explanation

Question 19 of 19

1

All employees are required to use SCBAs shall be evaluated annually and demonstrate the following proficiencies. Select the required ones.

Select one or more of the following:

  • Working knowledge of field maintenance and are familiar with SMFRA 200.1.1

  • Proficient in job scenarios including burn building, maze practice, and entanglement drills

  • Ability to pass a timed test for donning in under 1 minute

  • RIT drills including emergency airpack connections

  • Low profile and escape exercises

Explanation