Ne Bar
Quiz by , created more than 1 year ago

Standard Piping & Equipment for Steam Heating Systems Operation & Maintenance

66
0
0
Ne Bar
Created by Ne Bar over 9 years ago
Close

Chapter 3 - Steam Heating Systems

Question 1 of 11

1

In a gravity return system, the boiler should be placed

Select one of the following:

  • well below the lowest radiator

  • well below the highest radiator

  • at the same level as the radiators

Explanation

Question 2 of 11

1

The pressure balancing device that prevents the boiler pressure from forcing he water in the boiler into the return line is called a

Select one of the following:

  • Hartford loop

  • Pressure equalizer

  • Pressure control valve

Explanation

Question 3 of 11

1

When starting up a steam heating boiler it should be filled to:

Select one of the following:

  • 1/2 of a gage glass

  • 1/4 of a gage glass

  • 3/4 of a gage glass

Explanation

Question 4 of 11

1

If the water level falls too low during operation of a steam heating boiler the operator should

Select one of the following:

  • shut the boiler down

  • add more water immediately

  • lower the flame and add water to bring it up to a safe level

Explanation

Question 5 of 11

1

The Hartford Loop prevents the water in the boiler from

Select one of the following:

  • dropping below a safe level

  • contamination by impurities in the returning condensate

  • exceeding the highest safe level

Explanation

Question 6 of 11

1

This steam piping arrangement was also one of the first heating system to be developed.

Select one of the following:

  • one-pipe gravity return system

  • Hartford loop

  • two-pipe gravity steam system with steam traps

Explanation

Question 7 of 11

1

Slow or insufficient heat throughout a building heated by steam can be caused by:

Select one of the following:

  • too low a firing rate

  • air leaks

  • oversized piping

Explanation

Question 8 of 11

1

The piping and heating units of a steam heating system must be so arranged that:

Select one of the following:

  • steam can flow freely to all heating units

  • the condensate can flow freely to the heating units

  • the air can be kept at the top of the heating units

Explanation

Question 9 of 11

1

Which of the following would you expect to find in a steam heating system?

1. convectors
2. return traps
3. condensate tank
4. cushion tank

A) 1, 2, 3
B)2, 3, 4
C)1, 2, 4
D)1, 3, 4
E) 1, 2, 3, 4

Select one of the following:

  • A

  • B

  • C

  • D

  • E

Explanation

Question 10 of 11

1

Identify from the following list, which systems are a piping arrangements for steam heating systems.

1. Hartford Loop

2. Two-pipe with variable vacuum system

3. One-pipe gravity system

4. Two-pipe return trap system

A) 1, 2, 3, 4
B) 1, 2, 3
C) 2, 3, 4
D) 1, 3, 4
E) 1, 2, 4

Select one of the following:

  • A

  • B

  • C

  • D

  • E

Explanation

Question 11 of 11

1

Slow or insufficient heat in one or more rooms in a steam heated building can be caused by a:

Select one of the following:

  • faulty steam trap

  • faulty float switch

  • faulty heater

Explanation