Chapter 3 - Steam Heating Systems

Descripción

Standard Piping & Equipment for Steam Heating Systems Operation & Maintenance
Ne Bar
Test por Ne Bar, actualizado hace más de 1 año
Ne Bar
Creado por Ne Bar hace más de 9 años
66
0

Resumen del Recurso

Pregunta 1

Pregunta
In a gravity return system, the boiler should be placed
Respuesta
  • well below the lowest radiator
  • well below the highest radiator
  • at the same level as the radiators

Pregunta 2

Pregunta
The pressure balancing device that prevents the boiler pressure from forcing he water in the boiler into the return line is called a
Respuesta
  • Hartford loop
  • Pressure equalizer
  • Pressure control valve

Pregunta 3

Pregunta
When starting up a steam heating boiler it should be filled to:
Respuesta
  • 1/2 of a gage glass
  • 1/4 of a gage glass
  • 3/4 of a gage glass

Pregunta 4

Pregunta
If the water level falls too low during operation of a steam heating boiler the operator should
Respuesta
  • shut the boiler down
  • add more water immediately
  • lower the flame and add water to bring it up to a safe level

Pregunta 5

Pregunta
The Hartford Loop prevents the water in the boiler from
Respuesta
  • dropping below a safe level
  • contamination by impurities in the returning condensate
  • exceeding the highest safe level

Pregunta 6

Pregunta
This steam piping arrangement was also one of the first heating system to be developed.
Respuesta
  • one-pipe gravity return system
  • Hartford loop
  • two-pipe gravity steam system with steam traps

Pregunta 7

Pregunta
Slow or insufficient heat throughout a building heated by steam can be caused by:
Respuesta
  • too low a firing rate
  • air leaks
  • oversized piping

Pregunta 8

Pregunta
The piping and heating units of a steam heating system must be so arranged that:
Respuesta
  • steam can flow freely to all heating units
  • the condensate can flow freely to the heating units
  • the air can be kept at the top of the heating units

Pregunta 9

Pregunta
Which of the following would you expect to find in a steam heating system? 1. convectors 2. return traps 3. condensate tank 4. cushion tank A) 1, 2, 3 B)2, 3, 4 C)1, 2, 4 D)1, 3, 4 E) 1, 2, 3, 4
Respuesta
  • A
  • B
  • C
  • D
  • E

Pregunta 10

Pregunta
Identify from the following list, which systems are a piping arrangements for steam heating systems. 1. Hartford Loop 2. Two-pipe with variable vacuum system 3. One-pipe gravity system 4. Two-pipe return trap system A) 1, 2, 3, 4 B) 1, 2, 3 C) 2, 3, 4 D) 1, 3, 4 E) 1, 2, 4
Respuesta
  • A
  • B
  • C
  • D
  • E

Pregunta 11

Pregunta
Slow or insufficient heat in one or more rooms in a steam heated building can be caused by a:
Respuesta
  • faulty steam trap
  • faulty float switch
  • faulty heater
Mostrar resumen completo Ocultar resumen completo