4.11 Refrigeration Auxillaries and Operation

Pregunta 1 de 10

1

Suction pressure too low might be due to:

Selecciona una de las siguientes respuestas posibles:

  • System load too high

  • Not enough condenser cooling water

  • Receiver level too high

  • Receiver level too low

  • Faulty or closed expansion valve

Explicación

Pregunta 2 de 10

1

When changing ammonia systems, frost on the drum bottom indicates:

Selecciona una de las siguientes respuestas posibles:

  • Too much refrigerant

  • The ambient temperature is too high

  • Refrigerant drum is empty or very nearly empty

  • Refrigerant drum is still full

  • Pressure is too high

Explicación

Pregunta 3 de 10

1

A low-pressure control in a refrigerating system can be used for:

Selecciona una de las siguientes respuestas posibles:

  • Condenser pressure control

  • Starting and stopping the compressor

  • Purging non-condensable gases

  • Keeping the receiver pressure from getting too high

  • Evaporator pressure control

Explicación

Pregunta 4 de 10

1

In an indirect ammonia system using brine and water-cooled condenser, the discharge pressure is controlled by:

Selecciona una de las siguientes respuestas posibles:

  • The load on the brine

  • Regulating the expansion valve

  • Regulating the cooling water to the condenser

  • Using a pressure release valve

  • The amount of ammonia refrigerant used

Explicación

Pregunta 5 de 10

1

Where public occupancy is a concern when using Safety Group 2 refrigerants the safest systems are:

Selecciona una de las siguientes respuestas posibles:

  • Direct refrigeration

  • Indirect systems

  • Any available system

  • Automatic refrigeration

  • The C/S/A approved refrigeration systems

Explicación

Pregunta 6 de 10

1

The most efficient method of condenser cooling is

Selecciona una de las siguientes respuestas posibles:

  • Air cooled

  • Water cooled

  • Latent heat cooled

  • Diffusion cooled

  • Cooled by another refrigeration unit

Explicación

Pregunta 7 de 10

1

Before changing a new refrigeration installation:

Selecciona una de las siguientes respuestas posibles:

  • It should be filled with water first

  • The entire refrigerant containing system must be thoroughly tested for performance

  • It should be filled with refrigerant and tested for performance

  • The entire refrigerant containing system must be completely filled with water and hydrostatically tested

  • It should be filled with hydrogen and tested

Explicación

Pregunta 8 de 10

1

In a indirect ammonia vapour compression system using brine, the suction pressure is controlled by:

Selecciona una de las siguientes respuestas posibles:

  • The load on the brine

  • The flow of the cooling water to the suction side of the compressor

  • Throttling the metering valve

  • An equalization valve

  • The flow of the condensing water to the condenser

Explicación

Pregunta 9 de 10

1

Refrigeration application uses could include:

Selecciona una de las siguientes respuestas posibles:

  • Heating methods in industry

  • Gas distillation process

  • Refrigerant oil purification

  • Air conditioning humidifying

  • Air conditioning or gas dehydration

Explicación

Pregunta 10 de 10

1

The capillary tube has a

Selecciona una de las siguientes respuestas posibles:

  • Very small diameter

  • Medium sized diameter

  • Large diameter

  • Convergent-divergent cross-section

  • Concaved cross sectional area

Explicación