TRAVIS CANNING
Quiz por , criado more than 1 year ago

power engineering 3b2 Quiz sobre 4.12 Heat Exchangers and Cooling Towers, criado por TRAVIS CANNING em 01-03-2016.

76
1
0
TRAVIS CANNING
Criado por TRAVIS CANNING mais de 8 anos atrás
Fechar

4.12 Heat Exchangers and Cooling Towers

Questão 1 de 10

1

Which of the following are True?
1. Kettle reboilers have a large liquid volume
2. Kettle reboilers may use a weir to keep fluid above the tubes
3. It is important not to flood Thermosyphon reboilers.
4. Thermosyphons depend on a difference in fluid density to promote flow.

Selecione uma das seguintes:

  • 1,2,3

  • 1,2,4

  • 1,3,4

  • 2,3,4

  • 1,2,3,4

Explicação

Questão 2 de 10

1

In a Cooling tower the drift eliminators:

Selecione uma das seguintes:

  • Break the water into thin sheets to increase the surface area

  • Discharge the air at high velocity to minimize re-circulation

  • Induce the flow of air through the cooling section

  • Separate entrained moisture from the air

  • Prevent waves in the reservoir

Explicação

Questão 3 de 10

1

Which of the following are true for plate heat exchangers?
1. High turbulence helps prevent fouling
2. Heat transfers well through the thin plates
3. Not good for thick fluids
4. They have a low-pressure drop
5. Gasket placement is critical

Selecione uma das seguintes:

  • 1,2,3,4

  • 2,3,4,5

  • 1,3,4,5

  • 1,2,4,5

  • 1,2,3,5

Explicação

Questão 4 de 10

1

Which of the following are true for feed water heaters?
1. High pressure feedwater heaters are used between the BFP and boiler
2. Low pressure feedwater heaters are used between the hotwell and dearator
3. Turbine extraction steam is commonly used for feedwater heater
4. Feedwater heaters increase cycle efficiency, resulting in lower fuel costs
5. Feed water heaters are not considered pressure vessels

Selecione uma das seguintes:

  • 1,2

  • 1,3

  • 1,4

  • 1,2,3,4

  • 1,2,3

Explicação

Questão 5 de 10

1

Hairpin exchangers:

Selecione uma das seguintes:

  • Are mainly used when the exchange surface are exceeds 50 m

  • Are easily assembled

  • Are easily cleaned

  • Are used only for low pressures

  • Are rarely used for heat exchange surfaces below 18m2

Explicação

Questão 6 de 10

1

In one design of shell and tube exchanger, a floating head:

Selecione uma das seguintes:

  • Helps to allow for expansion due to heat

  • Helps the operator to control water hammer

  • Helps the millwright to flare the tubes

  • Can be constructed of plastic

Explicação

Questão 7 de 10

1

Concentric pipe heat exchangers

Selecione uma das seguintes:

  • Typically use concurrent flows

  • Always use a smooth bore annulus

  • Are bulky

  • Always use consecutive flows

  • Are used for low heat duties

Explicação

Questão 8 de 10

1

Which of the following are true for overhead aerial condensers?
1. The footprint influences the design choice
2. Air re-circulation is a way to control temperatures in a tube bank
3. Headers or header boxes contain plugs for tube cleaning
4. Freezing of tube bundles is not normally a concern even on cold days
5. The vertical type is only used for steam condensing

Selecione uma das seguintes:

  • 1,2,3

  • 2,3,4

  • 3,4,5

  • 1,3,5

  • 1,2,3,4,5

Explicação

Questão 9 de 10

1

The hyperbolic cooling tower has the advantages of:
1. Low initial cost
2. Low power consumption
3. Dependability
4. Minimum maintenance

Selecione uma das seguintes:

  • 1,2,3

  • 2,3,4

  • 1,3,4

  • 1,2,4

  • 1,2,3,4

Explicação

Questão 10 de 10

1

Which of the following are true for aerial heat exchangers?
1. A bay may have on or more tube bundles
2. A unit may have one or more bays
3. A bank may have on or more units
4. Temperature control may be attained by stop start or variable speed fans.
5. Cleaning the outside of coils is a regular maintenance chore.

Selecione uma das seguintes:

  • 1,2,3

  • 2,3

  • 2,3,4

  • 2,4,5

  • 1,2,3,4,5

Explicação