Neil Revollo
Quiz por , criado more than 1 year ago

Quiz #3

762
1
0
Neil Revollo
Criado por Neil Revollo aproximadamente 8 anos atrás
Fechar

Chapter 3 - Hydronic Heat Sources

Questão 1 de 20

1

Conventional gas- and oil-fired boilers are currently used in the vast majority of residential and light commercial hydronic systems in North America.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 2 de 20

1

The cast-iron sectional boiler is currently one of the most common boilers used in residential and light commercial buildings in North America.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 3 de 20

1

If a cast-iron boiler is significantly oversized and experiences long off-times between firing cycles, much of the heat stored in the boiler's thermal mass can be carried up the flue by air currents passing through the combustion chamber.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 4 de 20

1

Many boilers currently used in North America were designed with the intent that flue gases would condense within the boiler.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 5 de 20

1

Condensing boilers are designed with large heat exchanger surfaces capable of extracting more heat from the exhaust gases compared to the heat exchangers in conventional boilers.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 6 de 20

1

In full storage ETS systems, all energy used during the subsequent on-peak period is purchased and stored during the peak cycle.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 7 de 20

1

The term "hydronic heat pump" always refers to a heat pump that delivers heat to a flowing stream of water.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 8 de 20

1

The heating capacity of the heat pump drops rapidly with increasing source water temperature.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 9 de 20

1

It is not advisable to maintain water flow through the condenser whenever the heat pump is operating.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 10 de 20

1

The decision to use a wood-fueled boiler involves a time commitment much more demanding than for conventional heat sources operating on natural gas, propane, fuel oil, or electricity.

Selecione uma das opções:

  • VERDADEIRO
  • FALSO

Explicação

Questão 11 de 20

1

Most cast-iron sectional boilers are limited to use in __________ hydronic systems.

Selecione uma das seguintes:

  • "bare-bones"

  • packaged

  • closed-loop

  • distributed

Explicação

Questão 12 de 20

1

The combination of metal and water weight gives cast-iron boilers the ability to absorb a significant amount of heat. Such boilers are said to have a high __________.

Selecione uma das seguintes:

  • life cycle

  • thermal mass

  • efficiency factor

  • size

Explicação

Questão 13 de 20

1

One type of boiler design surrounds the combustion chamber with a water-filled heat exchanger. This arrangement is called a __________ boiler.

Selecione uma das seguintes:

  • hydraulic

  • condensation

  • steam

  • wet-base

Explicação

Questão 14 de 20

1

Analysis of combustion processes reveals that significant amounts of heat can be recaptured from the exhaust stream if the water vapor it contains can be _________.

Selecione uma das seguintes:

  • condensed within the boiler

  • expelled from the system

  • replenished regularly

  • minimized

Explicação

Questão 15 de 20

1

Boilers with low thermal mass tend to have __________ cycle efficiencies due to lesser amounts of heat remaining in the boiler following burner shutdown.

Selecione uma das seguintes:

  • lower

  • unpredictable

  • higher

  • dependable

Explicação

Questão 16 de 20

1

A boiler operates at __________ efficiency only when it is being fired continuously under nonvarying conditions.

Selecione uma das seguintes:

  • steady-state

  • measurable

  • DOE-certified

  • manufacturer

Explicação

Questão 17 de 20

1

A __________ is a device for converting low-temperature heat into higher temperature heat.

Selecione uma das seguintes:

  • thermal converter

  • radiating unit

  • flue gasket

  • heat pump

Explicação

Questão 18 de 20

1

A flow restriction or stoppage in the __________ can lead to rapid formation of ice crystals on the cold heat exchanger surfaces separating the water and refrigerant.

Selecione uma das seguintes:

  • storage tank

  • water source

  • evaporator

  • closed-loop

Explicação

Questão 19 de 20

1

In solar anti-freeze based combisystems, the outside heat dump provides a way for the system to shed excess heat. It is activated if the temperature of the thermal storage tank reaches a _________ upper limit.

Selecione uma das seguintes:

  • manufacturer recommended

  • DOE enforced

  • user-set

  • local fire code

Explicação

Questão 20 de 20

1

It is vital that the solar collectors and all exposed piping in a drain-back system be pitched a minimum of __________ toward the storage tank to allow complete drainage.

Selecione uma das seguintes:

  • 1/4 in./ft.

  • 1/2 in./ft.

  • 1/8 in./ft.

  • 1/16 in./ft.

Explicação