Questão 1
Questão
What is the purpose of Coombs control cells?
Responda
-
To ensure that AHG tests with negative results are not the false negatives
-
To ensure that washing removed all unbound antibody
-
To ensure that AHG was not omitted or inactivated
-
All of the above
Questão 2
Questão
What is a positive DAT?
Responda
-
In vitro sensitization of RBC with antigen
-
In vitro sensitization of RBC with antibody
-
In vivo sensitization of RBC with antibody
-
In vivo sensitization of RBC with antigen
Questão 3
Questão
A positive autocontrol in antibody detection procedures is usually indicative of:
Responda
-
Inadequate washing
-
Positive DAT
-
Positive IAT
-
two of the above
Questão 4
Questão
Why is it important to match the lot number on the panel cells?
Responda
-
The ABO group will change from lot to lot
-
Pattern of reactions will change from lot to lot
-
It is a requirement of the FDA
-
All of the above
Questão 5
Questão
In interpreting an antibody screen, which of the following questions might be asked to decipher the class of antibody?
Questão 6
Questão
What is an elution?
Responda
-
a technique used to dissociate IgM antibodies from sensitized RBCs
-
a technique used to dissociate IgG antibodies from sensitized RBCs
-
a technique used to reduce the zeta potential enhancing antigen binding
-
none of the above
Questão 7
Questão
What is tested in an antibody screen?
Responda
-
Patient red cells are tested against group O reagent screening cells
-
Patient serum is tested against group AB reagent screening cells
-
Patient serum is tested against group O reagent screening cells
-
Patient serum is tested against group A reagent screening cells
Questão 8
Questão
What might a positive antibody screen and a negative autocontrol indicate?
Responda
-
An alloantibody is coating donor cells after a transfusion
-
An autoantibody has been detected
-
An alloantibody has been detected
-
Drug-induced antibody reacting with patient cells.
Questão 9
Questão
When might you suspect multiple antibodies in a patient's serum?
Responda
-
Pattern of reactivity not fitting a single antibody
-
Variation in phase of reactivity
-
Variation in antibody reactivity strength
-
All of the above
Questão 10
Questão
One drop of Coombs control cells was added to a negative antibody screen. No agglutination was observed after centrifugation. What course of action is taken?
Questão 11
Questão
What is the shipping temp requirement for plasma?
Responda
-
1 to 6 degree F
-
1 to 6 degree C
-
-18 or higher degree F
-
-18 or lower degree C
Questão 12
Questão
Which of the following may not be used as a patient identifier?
Questão 13
Questão
Which of the following is not an enhancement media?
Questão 14
Questão
Additive solutions are approved for storage of red blood cells for how many days?
Questão 15
Questão
What is the current storage time and storage temp for platelet concentrates and apheresis platelet components?
Responda
-
5 days at 1 to 6 degrees C
-
5 days at 24 to 27 degrees C
-
5 days at 20 to 24 degrees C
-
7 days at 22 to 24 degrees C
Questão 16
Questão
Whole blood and RBC units are stored at what temperature?
Responda
-
1 to 6 C
-
20 to 24 C
-
37 C
-
24 to 27 C