4.11 Refrigeration Auxillaries and Operation

Descrição

power engineering 3b2 Quiz sobre 4.11 Refrigeration Auxillaries and Operation, criado por TRAVIS CANNING em 01-03-2016.
TRAVIS CANNING
Quiz por TRAVIS CANNING, atualizado more than 1 year ago
TRAVIS CANNING
Criado por TRAVIS CANNING aproximadamente 8 anos atrás
7
1

Resumo de Recurso

Questão 1

Questão
Suction pressure too low might be due to:
Responda
  • System load too high
  • Not enough condenser cooling water
  • Receiver level too high
  • Receiver level too low
  • Faulty or closed expansion valve

Questão 2

Questão
When changing ammonia systems, frost on the drum bottom indicates:
Responda
  • Too much refrigerant
  • The ambient temperature is too high
  • Refrigerant drum is empty or very nearly empty
  • Refrigerant drum is still full
  • Pressure is too high

Questão 3

Questão
A low-pressure control in a refrigerating system can be used for:
Responda
  • Condenser pressure control
  • Starting and stopping the compressor
  • Purging non-condensable gases
  • Keeping the receiver pressure from getting too high
  • Evaporator pressure control

Questão 4

Questão
In an indirect ammonia system using brine and water-cooled condenser, the discharge pressure is controlled by:
Responda
  • The load on the brine
  • Regulating the expansion valve
  • Regulating the cooling water to the condenser
  • Using a pressure release valve
  • The amount of ammonia refrigerant used

Questão 5

Questão
Where public occupancy is a concern when using Safety Group 2 refrigerants the safest systems are:
Responda
  • Direct refrigeration
  • Indirect systems
  • Any available system
  • Automatic refrigeration
  • The C/S/A approved refrigeration systems

Questão 6

Questão
The most efficient method of condenser cooling is
Responda
  • Air cooled
  • Water cooled
  • Latent heat cooled
  • Diffusion cooled
  • Cooled by another refrigeration unit

Questão 7

Questão
Before changing a new refrigeration installation:
Responda
  • It should be filled with water first
  • The entire refrigerant containing system must be thoroughly tested for performance
  • It should be filled with refrigerant and tested for performance
  • The entire refrigerant containing system must be completely filled with water and hydrostatically tested
  • It should be filled with hydrogen and tested

Questão 8

Questão
In a indirect ammonia vapour compression system using brine, the suction pressure is controlled by:
Responda
  • The load on the brine
  • The flow of the cooling water to the suction side of the compressor
  • Throttling the metering valve
  • An equalization valve
  • The flow of the condensing water to the condenser

Questão 9

Questão
Refrigeration application uses could include:
Responda
  • Heating methods in industry
  • Gas distillation process
  • Refrigerant oil purification
  • Air conditioning humidifying
  • Air conditioning or gas dehydration

Questão 10

Questão
The capillary tube has a
Responda
  • Very small diameter
  • Medium sized diameter
  • Large diameter
  • Convergent-divergent cross-section
  • Concaved cross sectional area

Semelhante

Mecânica
Alessandra S.
Como estudar com eficiência
Alessandra S.
Direito Administrativo
deboravasconcelos
II GUERRA MUNDIAL
Luis Augusto Oliveira
Enem - o que estudar
Luiz Fernando
República Velha
Vitor Gomes
Investigação científica
Claudina Quintino
Contextualização da Aula 4 - Gestão - Administração da Carreira Profissional
Fabrícia Assunção
Revisão 4 - PROVA DE SARGENTO - MARINHA - EA-HSG - ( Com Verificação )
Nilzeir Reis