Munition Handling and Loading Equipment: Quiz 2

Descrição

Quiz 2
Joseph Whilden J
Quiz por Joseph Whilden J, atualizado more than 1 year ago
Joseph Whilden J
Criado por Joseph Whilden J aproximadamente 8 anos atrás
18
1

Resumo de Recurso

Questão 1

Questão
How many different outputs can an A/M 32A-60 provide?
Responda
  • 2
  • 3
  • 4
  • 5

Questão 2

Questão
Which item is the only auxiliary power unit (APU) to provide both electrical and pneumatic power?
Responda
  • A/M 32A-60
  • A/M 32A-86
  • A/M 32A-95
  • MC-2A

Questão 3

Questão
Where is the A/M 32A-60 pneumatic duct hose stored?
Responda
  • On the unit's roof housing
  • In the rear storage compartment
  • In the front storage compartment
  • In the chassis storage compartment

Questão 4

Questão
Identify the output of the A/M 32A-95
Responda
  • 28 VDC
  • Bleed air
  • 120 VAC, single-phase, 400 Hz
  • 120/208 VAC, three-phase, 400 hz

Questão 5

Questão
Due to the expansion properties of fuel, an unmodified A/M 32A-95 fuel tank should not be filled more than approximately how full?
Responda
  • 1/3
  • 1/2
  • 5/8
  • 3/4

Questão 6

Questão
Which electrical output is supplied by the A/M 32A-86 generator set?
Responda
  • 110/120 VAC or 208/230 VAC
  • 115/200 VAC or 230/400 VAC
  • 120/208 VAC
  • 28 VDC

Questão 7

Questão
How many instruments/control panels must the operator make use of during operation of the A/M 32A-86 generator set?
Responda
  • 1
  • 2
  • 3
  • 4

Questão 8

Questão
Which panel of the A/M 32A-86 generator set has the circuit breaker to shut off current flow in case of an overload?
Responda
  • Generator control
  • Engine control
  • External AC
  • External DC

Questão 9

Questão
Which auxiliary power unit serves as an external power source for the MQ-1 and MQ-9 aircraft?
Responda
  • A/M 32A-60
  • A/M 32A-86
  • A/M 32A-95
  • Starter cart assembly (SCA)

Questão 10

Questão
Where is the control panel of the starter cart assembly (SCA) located?
Responda
  • Underneath a cover located at the top of the unit
  • On the engine monitoring panel
  • On the power outlet located on the right side of the generator set
  • On the starter cart assembly electronics tray

Questão 11

Questão
An operator is not required at or in the immediate vicinity of an in-use auxiliary power unit (APU) when they are practicing loading
Responda
  • High explosive munitions
  • Live nuclear weapons
  • Live chemical weapons
  • Inert training munitions

Questão 12

Questão
Fighter aircraft may be exempted from the 50 foot distance placement requirements of an auxiliary power unit (APU) during
Responda
  • Combat operations only
  • Simulated combat operations only
  • Combat or simulated combat operations
  • Combat, simulated combat, or adverse weather conditions

Questão 13

Questão
Which area must you void when operating units powered by turbine engines?
Responda
  • Engine air intake
  • Engine air exhaust
  • Engine plane of rotation
  • Power unit bleed air service hose

Questão 14

Questão
Which air compressor may be used to per ate small pneumatic tools?
Responda
  • MC-1A
  • MC-2A
  • MD-3
  • A/M 32A-60

Questão 15

Questão
How much air pressure is produced by the MC-2A air compressor?
Responda
  • 5 cfm at 200 psi
  • 15 cfm at 200 psi
  • 5 cfm at 3200 psi
  • 15 cfm at 3200 psi

Questão 16

Questão
Before you connect or disconnect a high-pressure service hose, you must make sure the system is not
Responda
  • Pressurized with more than 100 psi
  • Pressurized with more than 15 psi
  • Pressurized fully
  • Pressurized

Questão 17

Questão
Which power output of a portable floodlight set is used for powering common electrically powered hand tools?
Responda
  • 28 VDC
  • 115-120 VAC
  • 220-240 VAC
  • 225-300 VAC

Questão 18

Questão
The FL-1D can serve as a ground power source for MQ-1 and MQ-9 aircraft when used in conjunction with a/an
Responda
  • MC-2A air compressor
  • A/M 32A-60 generator set
  • A/M 32C-10A air conditioner
  • DCs40-75 "Sorensen" power supply unit

Questão 19

Questão
When can you use the floodlight receptacles for external power to operate accessories
Responda
  • When 115-120 VAC is required
  • When 110-115 VAC is required
  • When 235-300 VAC is required
  • Never, these receptacles cannot be used to operate accessories

Questão 20

Questão
How are flood lights positioned when working around aircraft?
Responda
  • Downwind from the A/C
  • At the end of their power cord
  • 50 feet away from the A/C nearest point
  • As far away as possible from the A/C, while still providing adequate lighting

Questão 21

Questão
In which position must the FL-1D's floodlight platform be placed during towing?
Responda
  • Any position
  • Lowered halfway
  • Lowered completely
  • Lowered just enough to clear overhead obstacles

Questão 22

Questão
Which storage compartment is the A/M 32C-10 duct hoses stored?
Responda
  • Unit's roof housing
  • Rear
  • Front
  • Chassis

Questão 23

Questão
Which A/M 32C-10 control panel will you use when operating the system?
Responda
  • High pressure air controls
  • Conditioned air controls
  • Generator control panel
  • Direct current (DC) power panel

Questão 24

Questão
How far from the supported aircraft should the A/M 32C-10 air conditioner be positioned for optimum unit operating efficiency and safety?
Responda
  • 8 to 10 feet
  • 10 to 12 feet
  • 15 to 30 feet
  • 50 feet minimum

Questão 25

Questão
Which per pound per square inch (psi) is the maximum amount of bleed-air pressure that may be applied to the -10 air conditioner?
Responda
  • 15 psi
  • 25 psi
  • 35 psi
  • 45 psi

Questão 26

Questão
How many operators are required to be present during the operation of the -10 air conditioner?
Responda
  • 1
  • 2
  • 3
  • 4

Questão 27

Questão
Which additional piece of aerospace ground equipment (AGE) is required during the operation of the polyalphaolefin (PAO)/air cooling cart?
Responda
  • A/M 32A-60 generator set
  • A/M 32A-86 generator set
  • A/M 32A-95 generator set
  • None, it is a self-contained system

Questão 28

Questão
How many fluid temperature modes are available on the polyalphaolefin (PAO)/air cooling cart?
Responda
  • 1
  • 2
  • 3
  • 4

Questão 29

Questão
How does the operator initiate the delivery of polyalphaolefin fluid once it has reached proper operating temperature?
Responda
  • By closing the aft restrictor valve
  • By opening the aft restrictor valve
  • By opening the aft restrictor manifold
  • The operator takes no action, the polyalphaolefin (PAO)/air cooling cart begins fluid delivery automatically

Questão 30

Questão
Which action must be ensured before making or breaking a connection between the polyalphaolefin (PAO)/air cooling cart and the aircraft?
Responda
  • Cart power is off
  • System is depressurized
  • Servicing lines are bled
  • Servicing lines are free of kinks

Questão 31

Questão
The cool-air hatch on the MJ-2A hydraulic test stand is located on the unit, by which location on the unit?
Responda
  • Rear
  • Front
  • Side
  • Top

Questão 32

Questão
Which personnel protective equipment (PPE) must be worn when you operate the MJ-2A?
Responda
  • Goggles
  • Ear protectors
  • Gloves
  • Coveralls

Questão 33

Questão
Identify the primary reason for making sure aircraft fittings are clean before attaching hydraulic servicing hoses?
Responda
  • Dirty fittings will cause damage to the threads of the connectors on the test stand
  • Dirty fittings can cause an incomplete seal with the hoses resulting in leaks at the attach points
  • Dirty fittings can introduce contaminants to the hydraulic system causing damage to valves and lines
  • Dirt can scour protective coatings off of the fittings that will allow then to corrode when bare metal is subjected to the environment

Questão 34

Questão
Which aircraft(s) require aircraft armament system personnel to use the self-generating nitrogen servicing cart (SGNSC)?
Responda
  • F-15, F-16, and F-22
  • B-1, B-2, and B-52
  • F-15 and F-15E
  • F-22 only

Questão 35

Questão
When using the self-generating nitrogen servicing cart (SGNSC) why is it important that waste gasses are not allowed to accumulate in an enclosed space?
Responda
  • Dangerous levels of carbon monoxide can build up displacing space
  • Dangerous levels of carbon dioxide can build up displacing oxygen
  • Excess nitrogen can pose a fire or explosion hazard
  • Excess oxygen can pose a fire or explosion hazard

Questão 36

Questão
Why is it important to prevent venting the self-generating nitrogen servicing cart (SGNSC) storage tanks in an enclosed space without sufficient ventilation?
Responda
  • Excess nitrogen can pose a fire/explosion hazard
  • Venting of high pressure gas is extremely loud and could damage hearing
  • A dangerous overpressure situation could occur causing harm to personnel and damage to structures
  • Large volumes of nitrogen can displace the oxygen in the air, making it possible for a person to suffocate without warning

Questão 37

Questão
Which precaution must be taken prior to attempting to loosen fittings, or removing tubes or hoses when using the self-generating nitrogen servicing cart (SGNSC)?
Responda
  • Ensure cart power is off
  • Ensure the entire system is depressurized
  • You must vent the pressure from that part of the system through the appropriate valve
  • Ensure the carts high pressure storage tanks main shutoff valves are in the "NO-FLOW" position

Questão 38

Questão
the maximum static load the B-1maintenance stand can sustain is
Responda
  • 300 pounds
  • 400 pounds
  • 500 pounds
  • 600 pounds

Questão 39

Questão
Identify the platform height range of the B-4 maintenance stand?
Responda
  • 3 to 7 feet
  • 4 to 8 feet
  • 3 to 10 feet
  • 4 to 12 feet

Questão 40

Questão
The hand pump for raising the B-4 maintenance stand is located on the
Responda
  • Platform near the ladder
  • Remote control unit (RCU)
  • Base of the stand near the aft castors
  • Base of the stand near the forward castors

Questão 41

Questão
Which maintenance stand is described as a scissors-type, with a variable height platform, and mounted on a long-legged caster-equipment base?
Responda
  • B-1
  • B-4
  • B-5
  • C-1

Questão 42

Questão
Identify the platform height range of the B-5 maintenance stand
Responda
  • 1 to 7 feet
  • 1 to 10 feet
  • 7 to 12 feet
  • 7 to 15 feet

Questão 43

Questão
Which stand can be used independently, or can be installed as an extension on the B-1maintenance stand?
Responda
  • B-2
  • B-4
  • B-5
  • C-1

Questão 44

Questão
The lifting capacity of the davit on the split deck is
Responda
  • 200 - 500 pounds
  • 250 - 500 pounds
  • 300 - 500 pounds
  • 350 - 500 pounds

Questão 45

Questão
If the split-deck maintenance platform's tape switches detect an obstruction during an operation, what will the switches stop on the unit?
Responda
  • Forward drive capacity only
  • Platform extension capability
  • Platform extension and lowering capabilities only
  • Forward drive, platform extension and lowering capabilities

Questão 46

Questão
During an operator's pre-use inspection of aerospace ground equipment (AGE), what is required by the operator to ensure proper unit operation?
Responda
  • Check the AFTO 781K
  • Check the AGE personnel as the status of the unit
  • Cycle the unit through the capabilities that you will use
  • Cycle the unit completely through its range of capabilities

Questão 47

Questão
Which AFTO form is used to annotate any defects you may find on your aerospace ground equipment (AGE)?
Responda
  • AFTO Forms 244 and 245
  • AFTO Form 349
  • AFTO Form 350
  • AFTO Form 781A

Semelhante

Hort100 Final Quiz 2
Madalyn Geuke
Introduction: What is Civilization?
Anita Thomer
2W151 Volume 1: Administration, Management, and Publications - Quiz 2
Joseph Whilden J
LAWS, REGULATIONS AND CONTROLLED SUBSTANCES
Rebecca West
8 Técnicas de Como Estudar Online
Alessandra S.
Exame Nacional de Português - 12° ano
Felipe Perreira
Simulado Geografia
Marina Faria
Coordenadas Geográficas
Carolina Foganholo
Técnicas de Estudo
vivi sousa
Simulado CTFL- Agile Tester
Larissa Trindade