3.9 Boiler procedures

Description

Quiz on 3.9 Boiler procedures, created by TRAVIS CANNING on 29/01/2016.
TRAVIS CANNING
Quiz by TRAVIS CANNING, updated more than 1 year ago
TRAVIS CANNING
Created by TRAVIS CANNING about 8 years ago
9
1

Resource summary

Question 1

Question
In order to avoid scale formation and corrosion in the _____, the make up water for the feedwater supply must be properly treated
Answer
  • dearator
  • boiler
  • furnace
  • tank

Question 2

Question
When examining the waterside surfaces, the inspector looks for signs of corrosion, pitting and ________ of the metal.
Answer
  • bulging
  • blistering
  • cracking
  • wearing

Question 3

Question
During the high-pressure flush, the blowdown valves should be disconnected, if possible, to prevent them from getting plugged with _________
Answer
  • water
  • dirt
  • rust
  • scale

Question 4

Question
Moisture absorbing material should be placed on trays inside the drums to absorb moisture from the ________
Answer
  • metal
  • tubes
  • air
  • fuel

Question 5

Question
Inert gas, such as nitrogen, is connected to the drum vent to maintain approximately ______ kpa, positive pressure.
Answer
  • 100
  • 35
  • 325
  • 500

Question 6

Question
When the pressure in the boiler steam drum drops to ______kPa, the drum vents are to be opened to avoid the formation of a vacuum within the boiler.
Answer
  • 170
  • 500
  • 35
  • 1000

Question 7

Question
Which of the following is not a common cause of furnace explosions
Answer
  • failure to purge the furnace adequately before start-up
  • admission of fuel to main burner before pilot flame or other ignition source is established.
  • Loss of id fan
  • attempting to light one burner off other burners, in operation
  • incorrect amount of air supplied to the burner can resulting in incomplete combustion

Question 8

Question
The operator must be familiar with manual operation of the ______system, in case of a system failure
Answer
  • generator
  • water
  • control
  • air

Question 9

Question
___________ storage is preferable for boilers that are out of service for an extended period of time or in locations where freezing temperatures.
Answer
  • Dry
  • Short
  • Wet
  • Long

Question 10

Question
In order for the gauge glass to show the correct level, all connections to the gauge glass and the water column, must be ______ to ensure they are clear and free from obstructions.
Answer
  • tight
  • purged
  • blowndown
  • unblocked
Show full summary Hide full summary

Similar

Mapa Mental - Estilos de Aprendizagem
miminoma
Work, Energy & Power: Quiz
alex.examtime9373
IMPERFECT TENSE - French
T W
An Inspector Calls: Sheila Birling
Rattan Bhorjee
GCSE Science - B1 - You and Your Genes - Genes, Chromosomes and DNA
GeorgeHaines
The Cold War: An Overview
Andrea Leyden
Edexcel Additional Science Biology Topic 2- Life Processes
hchen8nrd
GCSE History – The early years and the Weimar Republic 1918-1923
Ben C
Continents & Oceans
Thomas Yoachim
SFDC App Builder 1 (1-25)
Connie Woolard