  1. Radiation Safety and Radiographic Aids

    • Types: Alpha, Beta, X-ray, Gamma
    • Somatic - acute, v+ and d+, fatigue, skin burns
    • Carcinogenic - latent somatic, modified DNA - gene mutations
    • Genetic - ovaries/testes, birth defects
    • Principles - clinical justification, minimum exposure settings, dose limit
    • RPS - in practice, abides by local rules
    • RPA - external, advice and draws up local rules
    • Machine serviced annually
    • Radiolucent - foam wedges, troughs
    • Radiopaque - sandbags
    • ties/straps only used on anaesthetised patients
    • manual restraint - emergency only, must wear PPE
    • physical restraint - using aids
    • chemical restraint - better image, pain score?
  2. Endoscopes

    • Applications - BAL, internal views, biopsies, FB removal
    • Rigid scopes
    • Flexibles scopes
    • Videoscope - image projected onto screen, records, annotates
    • Fibrescope - image via eyepiece
    • Insufflation is essential for GI tract and lap spays
    • Endoscopes
  3. DPS Image Formation

    • Fogging - general blackening due to other radiation source
    • Flat film - dark film - KV too high
    • Soot and white wash - white film - KV too low
    • Absorption depends on: atomic no., specific gravity, thickness
    • Dark to Light: gas, fat, soft tissue/fluid, bone, metal
    • KV - penetrating power
    • mA - quality of photons (intensity)
    • Cathode (-ve) and Anode (+ve) are made of tungsten alloy
    • atomic no. 74
    • melting point 3380 degrees c
    • Production of Radiation
    • 1. mains electricity is stepped up with filament transformer
    • 2. current passes through cathode, heats up and releases cloud of electrons (thermionic emission)
    • 3. high electrical potential difference between cathode + anode
    • 4. uses more electricity so mains is stepped up by high tension transformer (kV)
    • 5. cloud of electrons repelled by cathode and attracted to anode
    • 6. electrons hit anode at speed = x-ray photons
    • 7. photons from primary beam exit via tube head via tube window
    • 8. heat is a by-product (99%) which is absorbed by copper block and cooled by oil bath