Gestalte GoConqr mit. Was sollen wir als Nächstes hinzufügen?

Karteikarten

EPR

Zena Dodds Englisch 31 Karten

Karten in diesem Stapel (31)

  1. 1what does EPR meanelectron paramagnetic resonance
  2. 2what does EPR do?detect species that have an unpaired electron ie radicals & transition metals
  3. 3what are the two spin numbers and which is parallel and whihc is antiSpin quantum number ms= -1/2, +1/2
    -1/2 = parallel +1/2 = anti
  4. 4what is the Boltzmann distribution equation and what does it donHigh/nlow= exp(-DeltaE/kT) (Boltzmann distribution),
    where k=1.38x10-23 J K-1 and T=temperature in kelvin (K)
    measure ratio of energies
  5. 5what is a fundamenal equation to do with EPR spectroscopy∆E = h = gmbB0
    – where h = Planck’s constant 6.63x10-34(J s), v = frequency (s-1) g = g factor (unitless), mB = Bohr magneton (J T-1) and B0 = magnetic field strength (T)
  6. 6what happens if there is no magnetic fieldno energy difference to measure
  7. 7what determine the population distributionThe absolute energy difference between the high and low energy states
  8. 8how does an eletron move between energy statesit must absorb or emit a photon
  9. 9ectron can be brought into a state at field by two ways:)using a fixed frequency and varying the magnetic field = continuous wave (CW) technique
    2) using a fixed magnetic field and varying the frequency = time domain/ pulsed technique
  10. 10using continous wave technique when does resonance happenwhen deltaE matches the fixed frequency. DeltaE increases as magnetic field increases
  11. 11what do CW spectrometers yeild1st derivative spectrum (similar to sine wave, maxima and minima =mid point of absorbance peak, Y=0 absorbance peak maximum)
  12. 12in pulsed EPR when is resonance acheivedfixed magnetic field and varying the frequency – resonance (absorption peak) only occurs when correct frequency is obtained
  13. 13where does B0 cause magnetizationalong the + z axis
  14. 14what does swtiching on B1 doPhase coherence brought about by B1 causing net magnetisation to move onto XY plane. Net magnetisation will align with B1 aftera certain time, often referred to as 90° pulse
  15. 15what are the T1 and T2 mechanisms• When B1 pulse switched off electronic spins relax back to equilibrium state - 2 main mechanisms
    T1 (longitudinal or spin-lattice relaxation)
    – Causes increase in Z magnetisation only
    T2 (transverse or spin-spin relaxation)
    –Causes decrease in xy magnetisation (and as a result an increase in Z)
    T1 > T2
  16. 16what is dead timelength of time required to wait for excess energy to dissipates from the system before detecting
    Deadtime significant in comparison to electron relaxation rate
    So spin-echo experiment performed -observe refocussed echo
  17. 17what is the spin echo recovery pulse sequence90x - t - 180y - t - echo (monitor echo)
    Z->Y ->turns to X -->180 turn past Y --> turn back to Y
  18. 18what are the EPR and NMR comparisons-EPR uses gigaherz NMR used megahertz
    -EPR is intrinsically more sensitive (Boltzmann distribution)
    -EPR requires weaker magnets (0.3-3 instead of 10-18 Tesla )
    -EPR has much broader lines due to much faster relaxation rate
    -– Pulsed EPR must be carried out at much lower temperature (50K cf 293K)
    -– At the moment can not excite whole spectrum
    – Pulsed EPR experiments are based on spin echo pulses
  19. 19What is the EPR instrumentationSource (microwave bridge)-> EPR tube (sample placed into cavity in magnetic field) --> detector (microwave bridge)--> spectrum (on computer screen)
  20. 20what is the future of EPR instruments• High field, high power
    • 1ns pulses - capable of exciting whole of nitroxide spectrum
    • Zero deadtime - therefore maximal sensitivity
  21. 21give a summary of EPR• EPR is a spectroscopic technique that detects species that have an unpaired electron(s)
    • An electron has a property called spin (Bar magnet). In magnetic field two orientations (+1/2 or -1/2)
    • ∆E = hv = gmBB0
    • Electron relaxes much faster than proton
    • Pulsed EPR relies on spin echo experiment
  22. 22what is EPR used forfor structural biology – can find out their primary sequences and know there 3D shape in solution
  23. 23what must happen to a molecule of interestEPR requires an unpaired electron, most systems do not have this so the molecule of interest must be labelled
  24. 24what are spin labels used forlabelling EPR silent molecues
  25. 25what is used as a spin labelNitroxides
    Nitroxides posses a stable unpaired electron – electron density mainly in N-O bond
    Nitroxide quite stable to most chemical reactions thus can have various R groups
    Nitroxide reversibly inactivated (EPR silent) by reducing agents
  26. 26what two techniues are used to determine if labelling incorpoartion workedmass spec and CW EPR
  27. 27Assess if incorporation benign to system– Functional assay e.g. turnover or binding
    – Structural assay
    • Circular dichroism - protein folding
    • Melting point - DNA duplexes
  28. 28how is EPR distance measured• between two unpaired electrons there exists a coupling that is dependent upon both angle and distance (r)
    • This coupling has a frequency that can be measured by EPR
    • This frequency is inversely related to the distance
    • Short distance (2.5nm) - large frequency (3.3MHz)
    Long distance (8nm) - small frequency (0.1MHz
  29. 29what is ENDORENDOR(Electron-Nuclear DOuble Resonance) is a technique that uses both microwave and radiofrequency applied fields, resulting in a hybrid EPR and NMR experiment. Sometimes described as EPR-detected NMR.
  30. 30how does endor workSample in magnetic field -> microwave radiation induces transitions between electronic spin states -> results in almost equal population in each of two spin states ->radio frequency signal is applied ->induces nuclear spin transitions (NMR) -> This situation results in changes to the EPR signal which can be interpreted in terms of the spatial arrangement of nuclei around the EPR active site
  31. 31what is ESEEMESEEM (Electron Spin Echo Envelope Modulation) is a magnetic resonance effect which can be observed in pulsed electron paramagnetic resonance experiments. Echo Envelope modulation arises when there is state mixing of the hyperfine levels. The modulation arises from the interference between pairs of excited EPR transitions

Informationen

Beschreibung
Karteikarten am EPR, erstellt von Zena Dodds am 13/12/2017.
Erstellt von
Zena Dodds
Aufrufe
0
Bewertung

Feedback

Worum geht es?

Was sollen wir als Nächstes hinzufügen?