Karteikarten
International Building Code Part 2
Karten in diesem Stapel (99)
- 1Structural plain concrete (un-reinforced) is permissible with each of the following except:Columns
- 2What is the minimum thickness of plain concrete exterior basement walls?7.5"
- 3What is the minimum thickness of plain concrete interior basement walls?5.5"
- 4Openings in concrete walls shall have not less than how many bars, and what size bars around the opening?1 bar on each side that is #5 bar extending 24" beyond the corners
- 5Vapor retarder for a slab on a grade shall be a minimum thickness of:6 mil
- 6What are the minimum requirements for a slab on grade?3 1/2" thick with a 6 mil vapor retarder with lap joints no less than 6"
- 7What is the minimum thickness for concrete slabs-on-grade?3.5"
- 8When placing shotcrete, the maximum size aggregate to be used is:3/4" aggregate
- 9When placing shotcrete, the maximum size of reinforcement shall be:No. 5 bars
- 10When placing shotcrete and bars smaller than No. 5 are used, the minimum clearance between parallel bars shall be how many inches?2.5" of clearance between parallel bars
- 11Lap splices of reinforcing bars used in shotcrete shall have aminimum clearance of:2"
- 12What is the closest reinforcement in pipe columns can be placed to the exterior steel shell?1"
- 13The minimum diameter of pipe columns in buildings not exceeding 3 stories or forty feet is:4"
- 14The minimum diameter of pipe columns in basements where the column is a secondary steel member, the minimum diameter shall be:3"
- 15Unused mortar shall be used within:2.5 hours
- 16What is the average compressive strength of type "N" mortar at 28 days?750 psi
- 17Most structural steel is ASTM:A-36
- 18The mortar bed on top of the footing should be between:1/4" - 3/4"
- 19What is the minimum bed joint when placed directly on the foundation?1/4"
- 20Head and bed joints for glass block shall be:1/4"
- 21The minimum length of end support of lintels shall be:4"
- 22What is the maximum on-center spacing for weepholes?33" on-center
- 23The minimum diameter of masonry weep holes shall be:3/16"
- 24Masonry columns used to support light-frame roofs over carports shall have a maximum column height of:12'
- 25What is the minimum thickness of a masonry weight bearing wall?6"
- 26What is the minimum thickness for a 3' high masonry foundation wall that supports one story of a structure with walls of light frame construction?6"
- 27The maximum height of an unreinforced 8" thick masonry parapet wall is how many inches?24"
- 28What would be the maximum support of a single brick tie for a multiple wythe wall?4.5 sq feet
- 29Roof diaphragms shall be anchored to a masonry wall with:1/2" diameter bolts embedded 15" into the masonry
- 30Bolts that are used for anchoring roof diaphragms are spaced:72" O.C.
- 31What is the minimum thickness for standard non load bearing glass block?3 7/8" Thick
- 32How many square feet of glass block are allowed in an exterior panel?250 square feet
- 33When a fireplace has a firebox opening of 5.7 square feet, the hearth shall extend a minimum of:16"
- 34When a fireplace has a firebox opening of more than 6 square feet, the hearth shall extend a minimum of:20"
- 35A masonry fireplace located in the interior of a building shall have a minimum clearance of:2" on the sides and 4" from the back
- 36What is the minimum height that a chimney shall extend above the point where it passes through the roof if the roof slope is 6/12?3'
- 37Masonry chimney walls shall not be less than how thick?4" thick
- 38Cold formed steel shall be protected against corrosion with:An approved coat of paint, enamel or other approved coating
- 39What is the minimum thickness of particle board underlayment?1/4" thick
- 40What is the maximum moisture content of lumber?19% moisture content
- 41What is the minimum board or sheathing thickness applied perpendicular to supports when rafter spacing is 24” o.c.?23/32" thick
- 42What is the required thickness of surface dry roof sheathing continuous over two or more spans with a 24" span?5/8" thickness
- 43What is the allowable maximum load for 5/8" wood roof sheathing, spanning 24" over two or more spans and strength axix parallel to supports?80 psf
- 44What is the minimum distance allowed for untreated wood floor joist to exposed earth?18"
- 45What is the minimum distance allowed for untreated girders to the grade below?12"
- 46What is the minimum distance for untreated framing to the grade below?8"
- 47What is the proper clearance around a girder entering a masonry or concrete pocket?1/2" of clearance
- 48What is the fastening schedule for a joist toe-nailed to a sill or girder?3 Nails of Size 8d common or Type 10d common
- 49What is the number and size of nails required to toe-nail a stud to a sole plate?4 Nails of Size 8d
- 50When a jack rafter is face nailed to a hip, how many 16d common nails are used?2
- 51The proper spacing of nails along the edge of plywood roof sheathing is:6" Spacing
- 52What is the minimum distance between untreated wood siding to exposed earth?6"
- 53Untreated wood is permitted where such wood is continously and entirely:Below the ground-water level or submerged in fresh water
- 541/2" gypsum sheathing has a maximum wall stud spacing of:24"
- 55Ends of header joists need hangers when they exceed what length?6 feet
- 56Braced wall line sills shall be anchored to the concrete or masonry foundations:4' on center
- 57Continous foundations are required at exterior walls only when maximum plan dimensions exceed:50'
- 58Foundation plates or sills resting on concrete or masonry foundations shall be bolted or anchored to the foundation with not less than:1/2" bolts embedded at least 7" and no more than 6 feet on center
- 59Anchor bolts embedded in a concrete slab for securing a bottom plate are spaced no further than how many feet?6'
- 60The Building Code allows you to cut what size notch at the end of a 2 x 10?2.5"
- 61What portion of a joist is not allowed to have a notch cut into it?The middle third
- 62What is the maximum size notch that can be cut into the top or bottom of a joist that is not near the edge?1/6 of the joist depth
- 63What is the minimum overlap for double top plates?48"
- 64What is the maximum stud spacing for non-bearing interior walls and partitions?28"
- 65What is the maximum spacing for 2 x 4 wall studs supporting roofs and ceilings only?24"
- 66What is the maximum stud spacing when installing gypsum board over the studs?24"
- 67A load-bearing stud may be notched to a depth not to exceed what percentage of its width?25%
- 68In a 2 x 4 load-bearing wall, what is the maximum size hole that can be bored through the stud?40%
- 69In a 2 x 4 non load-bearing wall, what is the maximum size hole that can be bored through the stud?60%
- 70Rafter ties are spaced how far apart?Not more than 4'
- 71How close can a hole be bored from the edge of a floor joist?2" from the edge
- 72What is the maximum diameter of a hole in a joist?1/3 of the joist depth
- 73Cement plaster over exterior wall studs requires galvanized weep screed with a:3 1/2" vertical leg at least 4" above the earth
- 74Smoke control systems shall have:Stand-by power
- 75Construction equipment and materials shall be stored and placed:So as not to endanger the public, workers or adjoining property
- 76Stumps and roots shall be removed from the soil to a depth of:12"
- 77The maximum slope for permanent fill is:50%
- 78Roof covering over walkways or sidewalks at construction sites must have how many feet clearance above the walkway?8' OF CLEARANCE
- 79A covered walkway is required to protect pedestrians during construction of a 60' building with what minimum distance from the street?5' from the street
- 80What is the minimum required width of walkways around a construction project?4' wide walkways
- 81If a fence is required at a jobsite, the minimum height would be:8' High
- 82Prior notification to neighbors of any work to begin shall be made:10 days prior to starting work
- 83What is the minimum space for fixed seating?18 inches
- 84A flight of stairs shall not have a vertical rise greater than ___ between fllor levels or landings.12 foot
- 85Stairs should always have a minimum of ____ headroom clearance?80 inches
- 86Fasteners for asphalt shingles shall penetrate the roofing materials a minimum of:.75 inch
- 87A cricket or saddle shall be installed on the ridge side of any chimney greater than how many inches wide?30 inches
- 88For asphalt roof slopes from 2/12 up to 4/12 underlayment shall be 2 layers. Apply a minimum___ inch wide strip of underlayment felt parallel with and starting at the eaves.19 inches
- 89Wood shake shall be laid with a side lap not less than how many inches?1.5"
- 90What is the exposure for No. 1 grade taper sawn shakes 24 inches long of naturally durable wood with a 4/12 pitch roof?8" of exposure
- 91When the ground water table is lowered and maintained at an elevation of not less than ___inches below the bottom of the lowest floor, the floors and walls shall be dampproofed.6"
- 92What is the minimum slope required for a building foundation with impervious surfaces present within 10 feet?2% slope
- 93Waterproofing floors shall be accomplished by placing a membrane of rubberized asphalt, or butyl rubber, or not less than ____ mil polyvinyl chloride with joints lapped not less than ___inches.6 mils polyvinyl chloride and 6 inch of joint lap
- 94What is the maximum amount of fly ash that can be added to concrete exposed to deicing chemicals?25%
- 95What is the maximum vertical and horizontal spacing of masonry wall ties?24" vertical and 36" horizontal
- 96Spacing between adjustable masonry wall ties should not exceed ___ inches vertically.16"
- 97When temperatures are very hot (100 degrees or 90 degrees with a wind velocity greater than 8 mph) brick mortar shall be discarded after ____ hours.1 hours
- 98What is the minimum thickness of structural sheathing on a 24 inch span that may be used on roofs?7/16" thickness
- 99What is the minimum nail length for fastening mechanical floor laminates?Not less than two and one-half times the net thickness of each lamination
Informationen
- Beschreibung
- South Carolina Commercial General Contractors Karteikarten am International Building Code Part 2, erstellt von Steven Hall am 23/12/2017.
- Erstellt von
- Steven Hall
- Aufrufe
- 0
- Bewertung
Mehr zu Structural Construction Requirements