Karteikarten
APU
Karten in diesem Stapel (45)
- 1what is a basic description of the APUgas turbine for ground ops only
- 2what does the APU supplystarter/generator 28 VDC
- 3Where does the APU feed into the electrical systemright main bus
- 4apart from power what does the APU supplybleed air to the ECS
- 5what does the APU fadec controlAutomatic start, operation and SU
- 6What fire detection systems does the APU have if anyAutomatic fire detection and Extinguisher, manual back up
- 7When would the APU shut off valve close? (6)PWR switch light pressed
Fire detected in tail cone
EXTG switch is pressed
AC takes off (WOW)
Fire Test Activated - 8how long does the bleed air need from being on speed?2 mins
- 9what can be said about the bleed systems for the engines and the APUyes, as long as the Engine bleed switches are not on
Engine bleed air always takes priority - 10what is the AFT safety valve powered byany bleed air
- 11how will you know if you have a bleed air faultyou get a fault advisory on the fire panel
- 12how will you know if the APU has failedAmber fail light on pwr switch light
- 13what other indications may you have with a fail or faultAPU caution on the CWP
APU FUEL VALVE CLOSED advisory light on (white) - 14what does the APU do in the event of a faultit shuts down automatically
- 15what must be done once the APU shuts down automaticallythe pwr switch must be moved to off
- 16what features relating to fire protection does the APU haveown fire bottle and fire extinguishing squib
- 17APDAdvanced Pneumatic Detection
- 18where is the APUs fire detection loopin the tailcone
- 19How is the APU fire protection test done?press 'APU PWR' ON
Press 'FIRE TEST' button
APU PWR 'fail' Legend on
'CHECK FIRE DETECT' on CWP
APU caution on CWP - 20what will the APU do if it detects a fireauto shutdown
- 21what lights should illuminate when APU fire protect test is initiatedall BUT
Fuel valve open
and blt low - 22what indications will you get if a fire is detected in the APUIndications as test except NO FAULT LIGHT
- 23after how long should the APU fire extinguisher bottle operate7 seconds
- 24how will you know if the bottle has firedyou'll get a low bottle indication
- 25what do we do if the extinguisher failspress EXTG
- 26what happens if the rear bay overheatsAPU starting is inhibited
APU shuts down if running - 27When must the APU be shut downBEFORE TAKE OFF
- 28when must the APU not be operating whilst unattendedwhen refuelling with pax onboard
- 29what must be done before turning the APU on when refuelling is taking placeinform and ask permission of the refueller
- 30when must the APU not be operated in terms of refuellingwhen gravity refuelling
- 31whats the min ambient temp for the APU-35 C
- 32whats the max ambient in normal conditions+50 C
- 33what is the max ambient with inlet louvres installed+ 21 C
- 34What must be on to ensure fire detection of the APUBattery Master must be on
- 35what are the APU starting limits1 start 60 secs on 5 mins off
2nd start 60 secs on - maintenance actions req
must wait 30 mins until 3rd start attempted - 36what may happen if the left tank reaches 480 kgs and collector tank has equalised following eng shutdownthe apu may be starved on fuel, stop or fail to start without any other indication, however prior to this it may surge if air enters the fuel lines
- 37where does the APU draw its fuelfrom the LH tank, collector bay
- 38how is the fuel fed to the APUgravity fed
- 39what does the amber WARN legend of the APU panel indicatethat the APU is available but not connected
- 40what may be the adverse result of this indicationthat the batteries may be discharging
- 41what are the indications that the APU Gen is onlinegreen ON gen switch light
APU gen load in MFD - 42how can you turn the APU gens onlinepressing the gen switch lights on
- 43what would prevent the APU gens from coming onlineExternal Pwr switch on
- 44when is the APU running on ground not permitted-when refuelling by gravity
icockpit unattended with pax when refuelling
when de-icing tail
when temps out of limits - 45What is the APU post automatic shut down procedureBLEED OFF
GENS OFF
PWR SWITCH SELECTED OFF