  1. 1SpO2: Use pulse ox on finger, head, or ear. SpO2 should remain >[blank_start]90[blank_end]%. SpO2 < [blank_start]90[blank_end]% or a decrease of [blank_start]4[blank_end] – [blank_start]5[blank_end]% indicates a pulmonary disorder.
    BP: Systemic or arterial to estimate normal response to exercise. Manual or automatic or indwelling arterial line.
    HR and ECG: [blank_start]Normal[blank_end] HR 60 – 100. [blank_start]Tachy[blank_end] HR >100. [blank_start]Brady[blank_end] HR <60. [blank_start]Flutter[blank_end] <200. [blank_start]Fibrillation[blank_end] too fast to count.
    [blank_start]Ventilation[blank_end]: Minute ventilation and RR, VO2 and VCO2 should be monitored.
    1. A90
    2. B90
    3. C4
    4. D5
    5. ENormal
    6. FTachy
    7. GBrady
    8. HFlutter
    9. IFibrillation
    10. JVentilation
  2. 2ECG Monitoring
    Brady: <[blank_start]60[blank_end]
    Normal: 60 – [blank_start]100[blank_end]
    Tachy: >[blank_start]100[blank_end]
    Flutter: >[blank_start]200[blank_end]
    Fibrillarion: [blank_start]too[blank_end] fast to count
    Estimating HR: Measure distance between 2 [blank_start]R waves[blank_end].
    Between [blank_start]3[blank_end]-[blank_start]5[blank_end] boxes: HR is 60-100
    Closer than [blank_start]3[blank_end] boxes: HR is >[blank_start]100[blank_end]
    Wider than [blank_start]5[blank_end] boxes: HR is <[blank_start]60[blank_end]
    HR = [blank_start]300[blank_end]/# of large boxes between R waves
    1. A60
    2. B100
    3. C100
    4. D200
    5. Etoo
    6. FR waves
    7. G3
    8. H5
    9. I3
    10. J100
    11. K5
    12. L60
    13. M300
  3. 3Arryhtmias
    Sinus Tach: Treat with [blank_start]O2[blank_end]
    Sinus Brady: treat with O2 and [blank_start]atropine[blank_end]
    [blank_start]PVC[blank_end]: Treat with O2 and consider causes
    Vtach with pulses: [blank_start]Cardiovert[blank_end]
    Vtach without pulses: [blank_start]CPR[blank_end], Defibrillate, [blank_start]Epinephrine[blank_end], Amio,
    Asystole – Confirm in 2 leads, start [blank_start]CPR[blank_end], [blank_start]epinephrine[blank_end]
    1st degree AV block: [blank_start]PR[blank_end] interval is >.[blank_start]20[blank_end] : Treat with [blank_start]Atropine[blank_end]
    2nd degree AV block: [blank_start]P[blank_end] waves with missing [blank_start]QRS[blank_end]: Treat with [blank_start]pacemaker[blank_end]
    3rd degree AV block: Treat with [blank_start]pacemaker[blank_end]

    [blank_start]Ischemia[blank_end]: Decreased blood flow to tissue: Depressed [blank_start]T[blank_end] waves
    [blank_start]Injury[blank_end]: Acute damage to tissue: Elevated [blank_start]ST[blank_end] segment
    [blank_start]Infarction[blank_end]: Necrosis of tissue: Significant [blank_start]Q[blank_end] waves
    1. AO2
    2. Batropine
    3. CPVC
    4. DCardiovert
    5. ECPR
    6. FEpinephrine
    7. GCPR
    8. Hepinephrine
    9. I20
    10. JPR
    11. KAtropine
    12. LP
    13. MQRS
    14. Npacemaker
    15. Opacemaker
    16. PIschemia
    17. QT
    18. RInjury
    19. SST
    20. TInfarction
    21. UQ

Informationen

Beschreibung
Der Nutzer hat seine Fachbereichs-Information gelöscht. Quiz am Monitoring During Exercise testing, erstellt von Gelöschter Nutzer am 19/08/2016.
Autor
Gelöschter Nutzer
Sprache
English
Aufrufe
37
Verlauf
Erstellt am 19 Aug 2016 · aktualisiert am 25 Aug 2016

Feedback

Worum geht es?

Wie gefällt dir das neue Design?

Dein Eindruck