GoConqr hat ein neues Design! Sag uns, wie es dir gefällt.

Quiz

ABG Analyzers

Gelöschter Nutzer 5 Fragen Aktualisiert am 25 Aug 2016

Quiz starten

Dieses Quiz enthält Fragetypen, die sich im gewohnten Player öffnen.

Fragen in diesem Quiz (5)

  1. 1ABG Analyzers
    Directly measures [blank_start]PCO2[blank_end] - Severinghaus, [blank_start]PCO[blank_end] - Clark, pH - [blank_start]Sanz[blank_end]
    HCO3, SaO2 and other values are [blank_start]calculated[blank_end]
    Formula for read out: (Barometric Pressure - [blank_start]47[blank_end]) x Fractional Concentration of [blank_start]gas[blank_end]
    1. APCO2
    2. BPCO
    3. CSanz
    4. Dcalculated
    5. E47
    6. Fgas
  2. 2Severinhaus Electrode
    Measures [blank_start]PCO2[blank_end]
    [blank_start]Glass[blank_end] electrode in [blank_start]lucite[blank_end] jacket
    Includes nylon spacer and [blank_start]teflon[blank_end] membrane
    1. APCO2
    2. BGlass
    3. Clucite
    4. Dteflon
  3. 3Clark Electrode
    Measures [blank_start]PO2[blank_end]
    Platinum cathode, silver-silver chloride anode, polypropolene membrane (gas [blank_start]permeable[blank_end])
    Using [blank_start]mylar[blank_end] membrane results in insufficient O2 diffusion
    Cleaning top with [blank_start]pumice[blank_end] periodically to clean [blank_start]protein[blank_end]
    1. APO2
    2. Bpermeable
    3. Cmylar
    4. Dpumice
    5. Eprotein
  4. 4Sanz Electrode
    Measures PH
    Reference Electrode Contains: [blank_start]KCL[blank_end] solution with known PH, has contsant [blank_start]electrical[blank_end] potential.
    Measuring electrode contains: [blank_start]Buffer[blank_end] Solution, silver-silver chloride wire and pH sensitive glass capillary tube
    Introduction of sample causes electrical [blank_start]potential[blank_end] to develop. Voltage difference is proportional to PH [blank_start]difference[blank_end]
    1. AKCL
    2. Belectrical
    3. CBuffer
    4. Dpotential
    5. Edifference
  5. 5Tonomotry
    Used for [blank_start]QC[blank_end] with ABG analyzers
    Allows precise gas mixtures to be [blank_start]equilibrated[blank_end] with buffer solution or whole blood samples
    Best method for precise control of [blank_start]PO2[blank_end] electrode
    Vert complex - not widely used
    1. AQC
    2. Bequilibrated
    3. CPO2

Informationen

Beschreibung
Equipment (Gas Analyzers) Quiz on ABG Analyzers, created by LeeAnna Shepherd on 08/15/2016.
Autor
Gelöschter Nutzer
Sprache
English
Aufrufe
36
Verlauf
Erstellt am 19 Aug 2016 · aktualisiert am 25 Aug 2016

Feedback

Worum geht es?

Wie gefällt dir das neue Design?

Dein Eindruck