  1. 1Because of the latent heat load, refrigeration machine operator was instructed to start the reciprocating plant for air conditioning. Of the following according to recommended practice, the first thing to do is:
    1. ATurn on chilled water pumps and open the bypass to lighten the load
    2. BInstall larger fuse to take the initial load and then turn on the cooling tower fans
    3. CTurn on chilled water pump, condenser water pumps and cooling tower fans
    4. DSet thermostat a few degrees higher
  2. 2The most important reason to use 2 compressors in a cascade system is to :
    1. AAccomplish lower temperature
    2. BPermit the use of inexpensive lubrication oil
    3. CAvoid the need for very high compression ratios
    4. DDivide the cooling load between 2 compressors
  3. 3The advantage of forced draft over natural draft cooling tower is
    1. AThe possibility of lower water out temp
    2. BThere is no dependence on natural wind velocity
    3. CUse of a smaller tower size
    4. DAll of the Above
  4. 4what is 29.92" HG in Kpa
    1. A101.3
    2. B101.28
    3. C101.26
    4. D103.2
  5. 5The rupture disk is always piped into the
    1. AHigh side
    2. BLow side
    3. CEither side of the system
    4. DNeither side of the system
  6. 6A fusible plug melts at
    1. A450 F
    2. B280 F
    3. C212 F
    4. D800 F
  7. 7When will the BTUs absorbed by the condensing water be the greatest?
    1. ALow cond temp, low cond water temp
    2. BHigh cond temp, High cond water temp
    3. CHigh Cond temp, Low Cond water temp
    4. DLow Cond temp, High Cond water temp
  8. 8Flooded Evaporators have high heat transfer per square foot, What may be a disadvantage?
    1. ARequires a smaller charge
    2. BRequires a larger charge
    3. CRequires the use of a TXV for proper feed
    4. DWater has to be drained daily
  9. 9Shell and tube condensers have the advantage of
    1. ARemoving heads for cleaning the water sides of the tubes
    2. BThe refrigerant connections do not have to be disrupted
    3. CUsing acid for cleaning
    4. DBoth A and B are correct
  10. 10Shell and coil condensers have the advantage of
    1. ARemoving the heads for cleaning the water sides of the tubes
    2. BThe refrigerant connections do not have to be disrupted
    3. CHas less of a chance of developing leaks
    4. DBoth A and B are correct

Informationen

Beschreibung
Quiz am RMO Exam , erstellt von mst915 am 01/07/2015.
Autor
mst915
Sprache
English
Aufrufe
343
Schlagwörter
rmo exam
Bewertung
Noch keine Bewertungen
Bewerte dieses Quiz
Bewerte dieses Quiz

Feedback

Worum geht es?

Wie gefällt dir das neue Design?

Dein Eindruck