Zusammenfassung der Ressource

Frage 1

Frage
In a two pipe central heating system:
Antworten
  • a. The flow and return water mixes
  • b. The flow and return water is kept separate
  • c. The flow and return water is at the same temperature
  • d. The flow water is at a lower temperature than the return water.

Frage 2

Frage
The boiler position can be higher than the hot water cylinder in a:
Antworten
  • a. System with microbore heating with gravity primaries
  • b. Combined hot water and heating system with vented primaries
  • c. One pipe gravity system
  • d. Fully pumped sealed system.

Frage 3

Frage
This symbol from BS 1192 indicates a central heating component. Where in a central heating system would this be found?
Antworten
  • a. Cold feed from the feed and expansion cistern
  • b. The primary flow to the hot water cylinder
  • c. Immediately after the circulator and before the zone valve
  • d.On a sealed system filling loop.

Frage 4

Frage
Which of the following components could be fitted with a remote sensor?
Antworten
  • a. A thermostatic radiator valve
  • b.A kickboard convector heater
  • c. A diverter valve
  • d.A two port zone valve.

Frage 5

Frage
Which one of the following components allows the customer independent control of the hot water and central heating system?
Antworten
  • a. Room thermostat
  • b. Cylinder thermostat
  • c.Programmer
  • d. Three port mid-position valve.

Frage 6

Frage
Which of the following assists in the removal of flux from central heating pipework?
Antworten
  • a.Adding an inhibitor to the system after commissioning
  • b.Setting the working temperature of the system to a maximum of 650 oC
  • c. Flushing the system out prior to the handover
  • d.Setting the circulator to maximum for 1 hour after soundness testing.

Frage 7

Frage
The steps to take prior to temporarily decommissioning a central heating system, so that an additional radiator can be installed, would include:
Antworten
  • a. Check for safe isolation of central heating system, then drain down
  • b.Switch off programmer so there is no call for heat, then drain down
  • c. Apply temporary continuity bonding to system, then drain down
  • d.Bung F&E and apply temporary continuity bonding to flow and return pipework.

Frage 8

Frage
The customer complains that the downstairs radiators are cold and the upstairs radiators are only lukewarm. This is likely to be caused by a faulty:
Antworten
  • a.Boiler
  • b. Three port mid-position valve
  • c. Room thermostat
  • d.Circulator.

Frage 9

Frage
. Hot water circulates to each radiator by gravity in which of the following systems?
Antworten
  • a. One pipe system
  • b. Fully pumped system
  • c. Microbore system
  • d. Two pipe reverse system.

Frage 10

Frage
A zone valve in an S plan central heating system is designed to:
Antworten
  • a.Allow the central heating system never to reach 1000 oC
  • b.Stop the circulator noise from entering the central heating system
  • c. Isolate the central heating circuit when there is no demand
  • d.Prevent the flow and return waters from mixing.

Frage 11

Frage
The main objective of installing a central heating system in a property is:
Antworten
  • a. Thermal comfort
  • b. To allow customer control of timings
  • c. To conserve fuel
  • d. To fully heat a property up to 180 oC

Frage 12

Frage
When installing a central heating system using polybutylene pipe, the most common jointing method used is:
Antworten
  • a. Compression type A fittings
  • b.Solvent welded fittings
  • c. End feed solder fittings
  • d.Push fit fittings.

Frage 13

Frage
Which Building Regulation covers the energy efficiency requirements for central heating systems?
Antworten
  • a. L1
  • b.P
  • c. H
  • d. 6700.

Frage 14

Frage
One advantage of installing a fully pumped central heating system is:
Antworten
  • a. It is cheap to install
  • b.It allows each room to be heated to a regulated temperature
  • c. It controls the heat recovery time economically
  • d. There is no danger of overheating.

Frage 15

Frage
The type of copper commonly used in the installation of central heating systems within domestic properties is:
Antworten
  • a. R290 hard
  • b.R250 half hard
  • c. R220 half hard
  • d. R290 soft coils.

Frage 16

Frage
. In which of the following situations is it important to insulate central heating pipework?
Antworten
  • a.Bathroom and north facing kitchen
  • b. From the boiler to the index radiator
  • c. The loft area and under the suspended timber floor downstairs
  • d.Any run of pipework over 3 metres in length, as per BS 12828.

Frage 17

Frage
What would be the main effect on the central heating system if the circulator was installed in the position shown in this diagram?
Antworten
  • a. The system would be under negative pressure
  • b. The system would be mostly under negative pressure
  • c. The system would be pumping over the open vent
  • d. The neutral position would be at the base of the open vent.

Frage 18

Frage
What would be the Delta T temperature between a system with a flow temperature of 600 oC, a return temperature of 400 oC, and an ambient air temperature of 200 oC.
Antworten
  • a. 100 oC
  • b. 200 oC
  • c. 300 oC
  • d. 400 oC

Frage 19

Frage
Identify one advantage of underfloor heating:
Antworten
  • a. Cheap and easy to install
  • b. No requirement for balancing the system
  • c.Even spread of heat in each room
  • d. Does not need to be fully pumped.

Frage 20

Frage
Out of the following locations, where would the air vents be located on a central heating system?
Antworten
  • a. Immediately above the circulator
  • b.At the top of every radiator
  • c. Just prior to each zone valve
  • d. On the cold feed to the air separator.
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Der Stephansdom
Karin Wanke
La politique - Vocabulaire
Gaelle Bourgeois
IKA-Theoriefragen Serie 18 (15 Fragen)
IKA ON ICT GmbH
BKF C95 (Fragen der Ziffern 3a - 3g)
Harald Koenig
Pädagogik Abitur 2016: Freud
Lena S.
Ökologie
Zami I.
Bevölkerungssoziologie Kytir WS18 (Univie)
Lissi Ix
Vetie Mikrobiologie 2013
Maria Jacob
Vetie Histopathologie 2013
Cedric-Bo Lüpkemann
Vetie Gerichtliche Veterinärmedizin
Fioras Hu
Vetie - Spezielle Pathologie 2016
Birte Schulz