  1. 1ST analysis can be performed on the patient with 1:1 ventricular pacing.
    1. ARichtig
    2. BFalsch
  2. 2The ST segment is:
    1. ANormally elevated in all leads
    2. BNormally isoelectric in all leads
    3. CNormally depressed in all leads
    4. DDamaged and ischemia causes the cells of the myocardium to become more or less excitable.
  3. 3ST segment measurements are displayed and trended in:
    1. AmmHg
    2. Bmm
    3. Ckpal
  4. 4The ST Leads that are being monitored depend on: (choose all that apply)
    1. AThe leads available based on the lead set used and electrodes applied.
    2. BThe Lead Placement selected - Standard or EASI
    3. CThe number of leads displayed on the Main Screen.
    4. D The leads setup for monitoring.
  5. 5 When ST Analysis is turned off:
    1. ANo ST analysis or arrhythmia analysis is performed.
    2. BNo ST analysis is performed but arrhythmia analysis continues.
  6. 6To turn off individual leads of ST:
    1. AChange to another screen
    2. B In the ST Analysis menu, select Setup ST Leads.
    3. CIn the ECG menu, select New Lead Setup.
    4. DIn the ST Analysis menu, select, select ST Analysis.
  7. 7Selecting Alarms in the ST Analysis menu:
    1. ATurns on/off all ST alarms.
    2. BAllows you turn off individual ST alarms.
    3. CSilences ST alarms for 5 minutes.
    4. DAllows you to select single-lead or multi-lead alarms.
  8. 8 Multi-lead alarms will cause an alarm only when:
    1. AAll monitored ST leads exceed the limits set for 15 seconds.
    2. BThree or more leads exceed the limits set for 15 seconds.
    3. CTwo or more leads exceed the limits set for 1 minute.
    4. DThree or more leads exceed the limits set for 1 minute.
  9. 9 ST alarms set using Auto Limits Wide: (choose all that apply)
    1. AChanges the alarm limits based on the last 5 minutes of data.
    2. B Change as the patient’s condition changes
    3. CChanges the alarm limits based on the last 1 minute of data.
    4. DWill not change until you change them manually or use AutoLimits again.
    5. EWill not set alarm limits in pathological range.