GoConqr hat ein neues Design! Sag uns, wie es dir gefällt.

Quiz

mix 7

Ángel Villahermosa González 15 Fragen

Quiz starten

Fragen in diesem Quiz (15)

  1. 1Q1.1 Isolating the BATT BUS from the GENERATOR BUSES allows the BATT BUS to be depowered while still retaining the services powered from the two GENERATOR BUSES.
    1. ARichtig
    2. BFalsch
  2. 2Q1.2 With the engine running and the park brake released, an amber GPU DOOR caution will appear on the MFD, if the GPU door is still open.
    1. ARichtig
    2. BFalsch
  3. 3Q1.3 The BATT BUS voltage and the sum of the battery currents are displayed on the Engine Monitoring Display (EMD).
    1. ARichtig
    2. BFalsch
  4. 4Q1.4 The four power switches on the ELEC panels in the PC-21 are magnetically latched. This means that when a power source switch in one cockpit is set to ON that its equivalent switch in the other cockpit will also be set to ON, and vice versa.
    1. ARichtig
    2. BFalsch
  5. 5Q1.5 A red GENS warning appears, if both generators are switched off using the GEN switches on the ELEC panel.
    1. ARichtig
    2. BFalsch
  6. 6Q1.6 Setting the bus tie override switch (BTC NORM) to the ISOL position isolates the ...?
    1. A... BATT BUS from the GEN 1 and 2 BUSES
    2. B... BATT BUS from the MISSION BUS
    3. CGEN 1 BUS from the GEN 2 BUS
    4. D. GEN 1 BUS from POWER BUS
  7. 7Q1.7 Before applying electrical power the pilot has to make sure that nobody is close to the flight controls. This is, because ...?
    1. A... accidental operation of the hydraulic actuators can occur, which could cause serious injury to anybody near the flight controls and airbrake
    2. Bone can get seriously injured by electric shocks
    3. C. the respective flight control might be set to the wrong default position
    4. Dfailures would be induced to the hydraulic system
  8. 8Q1.9 In the event that both generators fail, the BATT 1 and 2 power will still remain available, supplying the BATT BUS with the required power. Provided both batteries are fully charged, and that the discharge rate is less than 60A, this power supply will last for how many minutes?
    1. A30 minutes
    2. B90 minutes
    3. C60 minutes
    4. D45 minutes
  9. 9Q1.12 Which component is highlighted on the Electrical System cutaway image?Bild zu Frage 9
    1. ABattery 1 (BATT 1)
    2. BBattery 2 (BATT 2)
    3. CEmergency Battery
    4. DGenerator 1 (GEN 1)
  10. 10Q1.13 Which components are highlighted on the Electrical System cutaway?Bild zu Frage 10
    1. AGenerator Control Units (GCUs)
    2. BGenerators (1 and 2)
    3. CBatteries (1 and 2)
    4. DCircuit Breaker (CB) panels

Informationen

Beschreibung
Quiz am mix 7, erstellt von Ángel Villahermosa González am 17/07/2024.
Sprache
Español
Aufrufe
1
Bewertung
Noch keine Bewertungen
Bewerte dieses Quiz
Bewerte dieses Quiz

Feedback

Worum geht es?

Wie gefällt dir das neue Design?

Dein Eindruck