1How many different outputs can an A/M 32A-60 provide?
- A2
- B3
- C4
- D5
2Which item is the only auxiliary power unit (APU) to provide both electrical and pneumatic power?
- AA/M 32A-60
- BA/M 32A-86
- CA/M 32A-95
- DMC-2A
3Where is the A/M 32A-60 pneumatic duct hose stored?
- AOn the unit's roof housing
- BIn the rear storage compartment
- CIn the front storage compartment
- DIn the chassis storage compartment
4Identify the output of the A/M 32A-95
- A28 VDC
- BBleed air
- C120 VAC, single-phase, 400 Hz
- D120/208 VAC, three-phase, 400 hz
5Due to the expansion properties of fuel, an unmodified A/M 32A-95 fuel tank should not be filled more than approximately how full?
- A1/3
- B1/2
- C5/8
- D3/4
6Which electrical output is supplied by the A/M 32A-86 generator set?
- A110/120 VAC or 208/230 VAC
- B115/200 VAC or 230/400 VAC
- C120/208 VAC
- D28 VDC
7How many instruments/control panels must the operator make use of during operation of the A/M 32A-86 generator set?
- A1
- B2
- C3
- D4
8Which panel of the A/M 32A-86 generator set has the circuit breaker to shut off current flow in case of an overload?
- AGenerator control
- BEngine control
- CExternal AC
- DExternal DC
9Which auxiliary power unit serves as an external power source for the MQ-1 and MQ-9 aircraft?
- AA/M 32A-60
- BA/M 32A-86
- CA/M 32A-95
- DStarter cart assembly (SCA)
10Where is the control panel of the starter cart assembly (SCA) located?
- AUnderneath a cover located at the top of the unit
- BOn the engine monitoring panel
- COn the power outlet located on the right side of the generator set
- DOn the starter cart assembly electronics tray
11An operator is not required at or in the immediate vicinity of an in-use auxiliary power unit (APU) when they are practicing loading
- AHigh explosive munitions
- BLive nuclear weapons
- CLive chemical weapons
- DInert training munitions
12Fighter aircraft may be exempted from the 50 foot distance placement requirements of an auxiliary power unit (APU) during
- ACombat operations only
- BSimulated combat operations only
- CCombat or simulated combat operations
- DCombat, simulated combat, or adverse weather conditions
13Which area must you void when operating units powered by turbine engines?
- AEngine air intake
- BEngine air exhaust
- CEngine plane of rotation
- DPower unit bleed air service hose
14Which air compressor may be used to per ate small pneumatic tools?
- AMC-1A
- BMC-2A
- CMD-3
- DA/M 32A-60
15How much air pressure is produced by the MC-2A air compressor?
- A5 cfm at 200 psi
- B15 cfm at 200 psi
- C5 cfm at 3200 psi
- D15 cfm at 3200 psi
16Before you connect or disconnect a high-pressure service hose, you must make sure the system is not
- APressurized with more than 100 psi
- BPressurized with more than 15 psi
- CPressurized fully
- DPressurized
17Which power output of a portable floodlight set is used for powering common electrically powered hand tools?
- A28 VDC
- B115-120 VAC
- C220-240 VAC
- D225-300 VAC
18The FL-1D can serve as a ground power source for MQ-1 and MQ-9 aircraft when used in conjunction with a/an
- AMC-2A air compressor
- BA/M 32A-60 generator set
- CA/M 32C-10A air conditioner
- DDCs40-75 "Sorensen" power supply unit
19When can you use the floodlight receptacles for external power to operate accessories
- AWhen 115-120 VAC is required
- BWhen 110-115 VAC is required
- CWhen 235-300 VAC is required
- DNever, these receptacles cannot be used to operate accessories
20How are flood lights positioned when working around aircraft?
- ADownwind from the A/C
- BAt the end of their power cord
- C50 feet away from the A/C nearest point
- DAs far away as possible from the A/C, while still providing adequate lighting
21In which position must the FL-1D's floodlight platform be placed during towing?
- AAny position
- BLowered halfway
- CLowered completely
- DLowered just enough to clear overhead obstacles
22Which storage compartment is the A/M 32C-10 duct hoses stored?
- AUnit's roof housing
- BRear
- CFront
- DChassis
23Which A/M 32C-10 control panel will you use when operating the system?
- AHigh pressure air controls
- BConditioned air controls
- CGenerator control panel
- DDirect current (DC) power panel
24How far from the supported aircraft should the A/M 32C-10 air conditioner be positioned for optimum unit operating efficiency and safety?
- A8 to 10 feet
- B10 to 12 feet
- C15 to 30 feet
- D50 feet minimum
25Which per pound per square inch (psi) is the maximum amount of bleed-air pressure that may be applied to the -10 air conditioner?
- A15 psi
- B25 psi
- C35 psi
- D45 psi
26How many operators are required to be present during the operation of the -10 air conditioner?
- A1
- B2
- C3
- D4
27Which additional piece of aerospace ground equipment (AGE) is required during the operation of the polyalphaolefin (PAO)/air cooling cart?
- AA/M 32A-60 generator set
- BA/M 32A-86 generator set
- CA/M 32A-95 generator set
- DNone, it is a self-contained system
28How many fluid temperature modes are available on the polyalphaolefin (PAO)/air cooling cart?
- A1
- B2
- C3
- D4
29How does the operator initiate the delivery of polyalphaolefin fluid once it has reached proper operating temperature?
- ABy closing the aft restrictor valve
- BBy opening the aft restrictor valve
- CBy opening the aft restrictor manifold
- DThe operator takes no action, the polyalphaolefin (PAO)/air cooling cart begins fluid delivery automatically
30Which action must be ensured before making or breaking a connection between the polyalphaolefin (PAO)/air cooling cart and the aircraft?
- ACart power is off
- BSystem is depressurized
- CServicing lines are bled
- DServicing lines are free of kinks
31The cool-air hatch on the MJ-2A hydraulic test stand is located on the unit, by which location on the unit?
- ARear
- BFront
- CSide
- DTop
32Which personnel protective equipment (PPE) must be worn when you operate the MJ-2A?
- AGoggles
- BEar protectors
- CGloves
- DCoveralls
33Identify the primary reason for making sure aircraft fittings are clean before attaching hydraulic servicing hoses?
- ADirty fittings will cause damage to the threads of the connectors on the test stand
- BDirty fittings can cause an incomplete seal with the hoses resulting in leaks at the attach points
- CDirty fittings can introduce contaminants to the hydraulic system causing damage to valves and lines
- DDirt can scour protective coatings off of the fittings that will allow then to corrode when bare metal is subjected to the environment
34Which aircraft(s) require aircraft armament system personnel to use the self-generating nitrogen servicing cart (SGNSC)?
- AF-15, F-16, and F-22
- BB-1, B-2, and B-52
- CF-15 and F-15E
- DF-22 only
35When using the self-generating nitrogen servicing cart (SGNSC) why is it important that waste gasses are not allowed to accumulate in an enclosed space?
- ADangerous levels of carbon monoxide can build up displacing space
- BDangerous levels of carbon dioxide can build up displacing oxygen
- CExcess nitrogen can pose a fire or explosion hazard
- DExcess oxygen can pose a fire or explosion hazard
36Why is it important to prevent venting the self-generating nitrogen servicing cart (SGNSC) storage tanks in an enclosed space without sufficient ventilation?
- AExcess nitrogen can pose a fire/explosion hazard
- BVenting of high pressure gas is extremely loud and could damage hearing
- CA dangerous overpressure situation could occur causing harm to personnel and damage to structures
- DLarge volumes of nitrogen can displace the oxygen in the air, making it possible for a person to suffocate without warning
37Which precaution must be taken prior to attempting to loosen fittings, or removing tubes or hoses when using the self-generating nitrogen servicing cart (SGNSC)?
- AEnsure cart power is off
- BEnsure the entire system is depressurized
- CYou must vent the pressure from that part of the system through the appropriate valve
- DEnsure the carts high pressure storage tanks main shutoff valves are in the "NO-FLOW" position
38the maximum static load the B-1maintenance stand can sustain is
- A300 pounds
- B400 pounds
- C500 pounds
- D600 pounds
39Identify the platform height range of the B-4 maintenance stand?
- A3 to 7 feet
- B4 to 8 feet
- C3 to 10 feet
- D4 to 12 feet
40The hand pump for raising the B-4 maintenance stand is located on the
- APlatform near the ladder
- BRemote control unit (RCU)
- CBase of the stand near the aft castors
- DBase of the stand near the forward castors
41Which maintenance stand is described as a scissors-type, with a variable height platform, and mounted on a long-legged caster-equipment base?
- AB-1
- BB-4
- CB-5
- DC-1
42Identify the platform height range of the B-5 maintenance stand
- A1 to 7 feet
- B1 to 10 feet
- C7 to 12 feet
- D7 to 15 feet
43Which stand can be used independently, or can be installed as an extension on the B-1maintenance stand?
- AB-2
- BB-4
- CB-5
- DC-1
44The lifting capacity of the davit on the split deck is
- A200 - 500 pounds
- B250 - 500 pounds
- C300 - 500 pounds
- D350 - 500 pounds
45If the split-deck maintenance platform's tape switches detect an obstruction during an operation, what will the switches stop on the unit?
- AForward drive capacity only
- BPlatform extension capability
- CPlatform extension and lowering capabilities only
- DForward drive, platform extension and lowering capabilities
46During an operator's pre-use inspection of aerospace ground equipment (AGE), what is required by the operator to ensure proper unit operation?
- ACheck the AFTO 781K
- BCheck the AGE personnel as the status of the unit
- CCycle the unit through the capabilities that you will use
- DCycle the unit completely through its range of capabilities
47Which AFTO form is used to annotate any defects you may find on your aerospace ground equipment (AGE)?
- AAFTO Forms 244 and 245
- BAFTO Form 349
- CAFTO Form 350
- DAFTO Form 781A