Chapter 12 - Quiz

Descripción

Expansion Tanks
Neil Revollo
Test por Neil Revollo, actualizado hace más de 1 año
Neil Revollo
Creado por Neil Revollo hace casi 8 años
371
1

Resumen del Recurso

Pregunta 1

Pregunta
In systems that are open to the atmosphere, such as a non-pressurized thermal storage tank, the volume increase of heated fluid is accommodated by an expansion tank.
Respuesta
  • True
  • False

Pregunta 2

Pregunta
One inherent problem with standard expansion tanks is that the air and water they contain are in direct contact.
Respuesta
  • True
  • False

Pregunta 3

Pregunta
The air in a standard expansion tank is initially at atmospheric pressure.
Respuesta
  • True
  • False

Pregunta 4

Pregunta
Standard expansion tanks typically need to be drained and refilled with air at least once each year.
Respuesta
  • True
  • False

Pregunta 5

Pregunta
Many of the shortcomings of standard expansion tanks can be avoided by separating the air and water in an expansion tank.
Respuesta
  • True
  • False

Pregunta 6

Pregunta
The entire volume of system fluid reaches the maximum fluid temperature simultaneously.
Respuesta
  • True
  • False

Pregunta 7

Pregunta
Most modern diaphragm-type tanks use a butyl rubber or EPDM diaphragm.
Respuesta
  • True
  • False

Pregunta 8

Pregunta
It is good practice to install a pressure-regulator valve near the inlet of any expansion tank.
Respuesta
  • True
  • False

Pregunta 9

Pregunta
The expansion tank should always be connected to the system near the outlet port of the circulator.
Respuesta
  • True
  • False

Pregunta 10

Pregunta
Many systems with chronic "air problems" can be corrected by simply rearranging the piping so that the circulator pumps away from the point of no pressure change.
Respuesta
  • True
  • False

Pregunta 11

Pregunta
In a typical closed-loop hydronic system, the extra space caused by heated liquid is usually provided by a separate chamber called the expansion tank. This tank contains a volume of __________ that is compressed.
Respuesta
  • air
  • gas
  • water
  • sludge

Pregunta 12

Pregunta
A software module called Expansion Tank Sizer in the Hydronics Design Studio software is an aid for determining tank size and __________.
Respuesta
  • placement
  • pressurization
  • type
  • brand

Pregunta 13

Pregunta
When __________ occurs, there is no longer a cushion of air for the system's water to expand against.
Respuesta
  • waterlogging
  • deaeration
  • thermal shutdown
  • hydraulic separation

Pregunta 14

Pregunta
The static pressure at the expansion tank connection when the system is filled is based on the height of the system piping above the expansion tank, the type of fluid used, and a customary allowance for __________ psi pressure at the top of the system for proper operation of the air vents.
Respuesta
  • 1.5
  • 3.33
  • 5.0
  • 7.5

Pregunta 15

Pregunta
In a diaphragm-type expansion tank, since the diaphragm separates the fluid from the air, the air __________ the fluid.
Respuesta
  • cools
  • easily combines with
  • is proportional to
  • cannot be reabsorbed by

Pregunta 16

Pregunta
A properly sized diaphragm-type expansion tank allows the pressure relief valve to reach a pressure of about __________ psi lower than its rated opening pressure when the system reaches its maximum operating temperature.
Respuesta
  • 1.25
  • 3.33
  • 5.0
  • 6.66

Pregunta 17

Pregunta
Expansion tanks have maximum pressure and temperature ratings. This information is stamped on the label of the tank. Typical ratings are __________ psi and 240ºF.
Respuesta
  • 5.0
  • 60.0
  • 25.0
  • 86.0

Pregunta 18

Pregunta
The __________ fixes the pressure of the system's fluid at its point of attachment to the piping. This is called the point of no pressure change.
Respuesta
  • circulator
  • heat emitter
  • expansion tank
  • diaphragm

Pregunta 19

Pregunta
When __________ circulators are used, the header they connect to should be located close to and just downstream from the point where the expansion tank is connected.
Respuesta
  • multiple zone
  • variable speed
  • hydraulic
  • single zone

Pregunta 20

Pregunta
It is __________ to install two or more expansion tanks at different locations within a system.
Respuesta
  • standard procedure
  • a manufacturer's recommendation
  • not advisable
  • the user's requirement
Mostrar resumen completo Ocultar resumen completo

Similar

Coronary 1 Practice
romalsp
Quotes from William Shakespeare's Romeo and Juliet
cecicurtis
Exam Part 1 of Nursing 112 FInal GBCC
Tess Nicholson
Life Science 7 Final Exam
pcsalazar
Motivational Interviewing
Julie HEYRMAN-COMPERNOLLE
AP Environmental Science
sabrinapar22
Obligations and Contracts - Provisions
mitchdeocampo
types of bullying
Gabriela Morales
Chapter 11 - Quiz
Neil Revollo
PBSC BSC1011L Final Exam Study Guide
Emily W
CGC 1D/P Geography Mind Map
MrsPG