Radiographic Exposure- Unit 4: Exposure Technique

Alex Ertmer Inglés 85 fichas

Fichas del conjunto (85)

  1. 1A quality radiographic image accurately represents the:Anatomic area of interest
  2. 2The _____ of the anatomic structures & the ______ of their structural lines recorded determine the overall ______ of the radiographic image.Visibility
    Accuracy
    Quality
  3. 3Visibility of the recorded detail refers to the _____ & _____ of the image.Brightness
    Contrast
  4. 4Amount of luminance (light emission) of a display monitor.Brightness
  5. 5Amount of overall blackness on the processed image.Density
  6. 6Another term for brightness.Density
  7. 7The primary factor that affects the amount of brightness/density produced in an image is the amount or quantity of radiation (_____) reaching the IR.mAs
  8. 8____ ____ has more of an effect on the brightness of the image rather than mAs.Computer Processing
  9. 9A lack of contrast makes an object appear:Homogenous
  10. 10Differences in the brightness levels or densities.Contrast
  11. 11The range of brightness levels is a result of the _____ differential attenuation of the x-ray photons.Tissues'
  12. 12What tells you that you used the correct technique factors that the IR received?Exposure Indicator
  13. 13The four MAJOR things to evaluate for a properly exposed radiograph is:Detail
    Distortion
    Contrast
    Density
  14. 14Sets the midpoint of the range of densities visible in the image.Window Level
  15. 15Moving the window down down to a low pixel value (Decreases/Increases) ______ the brightness on the display monitor.Decreases
  16. 16Moving the window level up to a high pixel value (Decreases/Increases) ______ overall brightness on the display monitor.Increases
  17. 17______ controls the radiographic contrast.Window Width
  18. 18A narrow window width means:Lower Contrast
  19. 19A wider window width means:Higher Contrast
  20. 20The product of mAs is:mA & Time
  21. 21Directly proportional to the amount (quantity) of radiation.Milliamperage (mA)
  22. 22Directly proportional to radiation quantity.Exposure time (Time)
  23. 23mA X Time =mAs
  24. 24As mAs is increased, the quantity of radiation reaching the IR is (Increased/Decreased) _______.Increased
  25. 25As mAs is decreased, quantity of radiation reaching the IR is (Increased/Decreased) ______.Decreased
  26. 26A visible change in density requires a minimum amount of change in mAs be ______.30%
  27. 27mA & time have an inverse proportional relationship when _____ the same mAs.Maintaining
  28. 28Doubling or halving your mAs means you're:Doubling or halving your density.
  29. 29This alters the amount & penetrating ability of the x-ray beam.Kilovoltage
  30. 30Increasing or decreasing the ____ changes the amount of radiation exposure to the IR, and the contrast produced within the image.kVp
  31. 31A change of 15% in kVp will cause a doubling or halving of the density on the radiograph. (The same way doubling/halving the mAs affects on image)15% Rule
  32. 32Quantum Noise/Mottle occurs because of:Low mAs
  33. 33Over exposure to the patient occurs because of:High mAs
  34. 34When increasing the kVp by 15%, you need to decrease the mAs by ____.Half
  35. 35When decrease the kVp by 15%, you need to increase the mAs by ____.Double
  36. 36Maintaining the density by applying by the ___ Rule.15% Rule
  37. 37The controlling factor of contrast.kVp
  38. 38An increase in ____ causes a difference in the X-ray tube because it's causing more energy photons.kVp
  39. 39When an anatomic structure shows up too white, you need to _____ kVp because to much was absorbed & NOT reaching the IR.Increase kVp
  40. 40What are the technical factors affecting density?kVp
    mAs
  41. 41What are the geometric factors affecting density?SID
    FSS
    Anode Heel Effect
  42. 42What materialistic factors affect density?Filtration
    Beam Restriction
    Grids
  43. 43Distance or SID will alter the _____ of the x-ray beam reaching the IR according to the inverse square law.Intensity
  44. 44Increased kVp yields increased _____.Scatter Radiation
  45. 45SID or Distance affects the amount of radiation reaching the _____ & _____.Patient & IR
  46. 46As the distance increases, the same amount of radiation will spread over an area that is created than the original, decreasing the beam's ______.Intensity
  47. 47X-ray photons diverge as they travel _____ from the source.Away
  48. 48If the distance is (Longer/Shorter) ______, the photons of not diverge as much & are then concentrated on a smaller area.Shorter
  49. 49The intensity of the x-ray beam is _____ proportional to the square of the distance from the source.Inversely
  50. 50Increase distance (SID), ______ (Increase/Decrease) the intensity of the beam, which (Increases/Decreases) _____ the density on the image.Decreases & Decreases
  51. 51The intensity of the x-ray beam is inversely proportional to the square of the distance from the source.Inverse Square Law
  52. 52A (Smaller/Larger) _______ focal spot will utilize greater incident electron stream vs. (Small/Large) _______ focal spot.Larger/Small
  53. 53______ Only affects density when unit not calibrated correctly.Focal Spot Size
  54. 54_______ Involves the intensity of radiation within the x-ray beam & the effect that this would have on the density on the image.Anode Heel Effect
  55. 55Anode Heel Effect depends on:-SID
    -Field Size
    -Part
    -Angle of Anode
  56. 56Anode Heel Effect is more pronounced:-Collimation is wide open
    -With a large IR
    -With shorter SID
    -Steeper Anode Angle
  57. 57You should only repeat an image technique wise if you need to make a ______ change.50% Change
  58. 58Two #'s to remember mAs with when changing techniques.-30%
    -Double/Half
  59. 59Photons are created at the ______.Focal Spot
  60. 60The smaller the focal spot, the better the _____.Detail
  61. 61The bigger the focal spot, the worse the ______.Detail
  62. 62Manufacturers automatically control the ______ of radiation that the focal spots cam produce.Quantity
  63. 63Focal Spot routinely affects density? (TRUE/FALSE)False
  64. 64The Anode side of the tube, the beam is (More/Less) _______ intense. On the Cathode side of the tube, the beam is (More/Less) ______.-Less
    -More
  65. 65Beam intensity is measure in ______Roegtan or milliroegtan
  66. 66______ of the beam is not uniform throughout all parts of the beam.Intensity
  67. 67The variation in beam intensity is greater at a ______.Shorter SID
  68. 68Variation of intensity can be as much as ______% change between anode & cathode sides. **Can be more pronounced with steeper angle**45%
  69. 69The anode should be placed at the _____ of the bed.Head end of the table
  70. 70______ body part should be towards the cathode.Thickest
  71. 71______ part if the body should be towards the anode side of the table.Thinner
  72. 72The intensity of the beam is greater at the _______ side of the X-ray tube.Cathode
  73. 73Have a proper placement of the part means a more uniform density along the ______ ______ of the image.Long Axis
  74. 74Beam is weaker on the anode side of the tube than on the cathode side (Put anode side of tube by thinnest body part in the beam).Anode Heel Effect
  75. 75______ affects x-ray quantity. **Results in higher beam quality**Filtration
  76. 76Even though filters reduce the intensity of the primary beam, they do NOT reduce the intensity of the ____ ____ reaching the IR.Remnant Beam
  77. 77Radiographic density will (Increase/Decrease) ______ whenever filtration is added.Decrease
  78. 78Beam restrictors includes:-Collimation
    -Aperture Diaphragms
    -Cones/Cylinders
  79. 79Reducing field size will ______ density. (Increase/Decrease)Decrease
  80. 80Why does reducing the field size decrease density?Because it will decrease unwanted scatter.
  81. 81The purpose of a grid is to remove:Scatter before it reaches the IR.
  82. 82The higher the grid ratio, the (More/Less) _____ for density.Less
  83. 83Adding, removing, or changing grids require an adjustment in _____ to maintain radiation exposure to the IR.mAs
  84. 84The amount of the beam that is absorbed by the patient depends on:-Thickness of part
    -Type of tissue (Atomic #)
    -Contrast Material
    -Pathology
  85. 85Thickness of body part can be altered by:-Patient's Age
    -Pathology
    -Body Habitus
    -Body Development (PEDS/GER/ADULT)
    -Cast Materials
    -Tube Angulation