  1. 1what is the voltage of the electrical system28 v dc
  2. 2what is the voltage and type of the main batteries24vdc nicad batteries x 3
  3. 3how many generators are in the system5
    2 dc
    2 ac
    1 apu
  4. 4how many trus are in the system2
  5. 5EPCUelectrical power control unit
  6. 6EPGDSelectrical power generation and display system
  7. 7what is the EPCUs role (4)monitor
    reconfigure
    communicate with the ESID
    activate warning and cautionary light
  8. 8What can be said about the generator switcheswe never turn them off
  9. 9what is the purpose of the ESID panelto represent different pages on the MFD
  10. 10What does the - meanits discharging
  11. 11what does no sign meanits charging
  12. 12what does + meanits over charging
  13. 13what does +1.2its over charging but 120% overloaded
  14. 14what must you do when the voltage is less than 27.5 VDCturn the batteries off
  15. 15what is the minimum for a gpu/apu start26 VDC
  16. 16whats the minimum for a Main/Ess bus power up23 VDC
  17. 17what is the minimum for a battery start22V
  18. 18what is the max battery load for engine start0.4
  19. 19what is the max battery load for takeoff0.1
  20. 20what does this 0.1 ensurethat you have 45 mins battery power on takeoff
  21. 21what is the minimum battery temperature for take off-20 C
  22. 22when are the L and R ESS buses tiedPERMENANTLY TIED
  23. 23What does the battery master connectthe Battery to the Ess Bus
  24. 24what is the avionics bus normally powered bythe Left ESS bus
  25. 25what can the Avionics bus also be powered byThe main or standby battery
  26. 26what is the purpose of Battery Switchesthey connect the batteries to the MAIN buses for the purpose of charging
  27. 27when is the battery master turned onbefore the batteries
  28. 28when are the main Buses tiedonly for start up and shutdown
  29. 29When will the battery heat indication be whitebelow 50C
  30. 30when will the battery heat indication turn yellow?50C to 65C inclusive
  31. 31when will the battery heat indication turn redabove 65 C
  32. 32What will happen if the battery temperature exceeds 71 Chot batt WARNING on CWP will illuminate
  33. 33what can be said about the HOT BATT BUSIt is always live
  34. 34what does the hot batt bus power-clocks
    -refuelling panel and associated SOVs
    -boarding lights
    -FLT DCK emergency dome lights
    -pa when emergency lights are activated
    -Batt Master
    -Fire extinguishing squibs
    -Hydraulic and Fuel SOVs
  35. 35??? what does the HOT BATT bus form part ofthe R Ess bus
  36. 36Where are the hot batt bus circuit breakers foundthe R ESS CB panel marked battery power
  37. 37what does the Avionics Bus powerISI
    Standby compass lights
    VHF1
    Storm lights
  38. 38ISIintegrated standby unit
  39. 39What do the DIODES preventthe standby battery and main ess buses from feeding the main feeder buses
  40. 40what happens to the voltage between the ESS and MAIN busesthere's a 0.7 drop due to the diodes
  41. 41GCUgenerator control unit
  42. 42what parts of the electrical system have GCUsBoth DC GENS
    APU GEN
    DC EXTERNAL PWR
  43. 43What do the secondary buses powerthe non essential DC services
  44. 44if you only have one generator functioning what will happenit will load shed the secondary buses
  45. 45what does the AC power (5)ice protection
    galleys
    AUX fuel pumps
    SPU (standby power unit)
    TRUs
  46. 46what type are the AC gensEngine driven
  47. 47what are the AC gens connected tovariable frequency 115 V buses through switches on the AC panel
  48. 48what is required to power the entire electrical system1 ac generator
  49. 49where are the stater generators mountedon the accessory gearbox of each engine
  50. 50what can the generators also act asstarter motors
    revert to generator operations once started
  51. 51what do the GCU protect against/ regualte to28.5 VDC
    over current
    over voltage and undervoltage
  52. 52how are the DC generators cooledair cooled
  53. 53where are the AC Gens drivenfrom the RGB
  54. 54what happens at 200 rpmstart/ fx
  55. 55what happens at 400 rpmac gens come online
  56. 56what happens at 660 rpmidle prop
  57. 57what do the ac gen GCUs regulate to115 V AC average over 3 phase
  58. 58how are the AC GENS cooledoil cooled
  59. 59how many oil systems does the AC haveonly 1
  60. 60what is the amperage of the TRU300 amps
  61. 61where are the TRUsin the nose compartment
  62. 62how are the TRUs cooledair cooled
  63. 63where does the GPU connectL main dc bus
  64. 64what is the voltage of the GP27 V
  65. 65what amperage is the GPU limited to1000 A
  66. 66between what voltage is the EPCU protected22-31 V
  67. 67what is the APU power inhibited byDC EXT PWR
  68. 68where is the APU gen monitoredon the MFD ELEC page
  69. 69when are the ESS buses poweredwhen the batt master is on
  70. 70when are the main buses poweredwhen the main and aux battery are on
  71. 71when is the secondary bus poweredwhen both DC gens are on
  72. 72what happens when you get a TRU failureSEC BUS TIE CONTACTOR CLOSES
  73. 73What does the EPCU do in the event of a DC bus failureisolates it
    monitors it for 5 seconds for transient faults
    if still transient fault detected, will cut all power to that side of the system
  74. 74what 4 cautions can you expect to see if you have a L DC Bus faultAUX BATT
    STBY BATT
    DC BUS
    #1 DC GEN
  75. 75what 3 cautions can you expect if you get a R DC bus faultmain batt
    #2 DC gen
    DC BUS
  76. 76how can you spot of the EXTERNAL POWER has gone offthe recirc fan will go off
    cabin toliet lights will go out
  77. 77what indications do you get on the FLT DCK for a secondary bus faultno indications
  78. 78what will the EPCU do in the event of a secondary bus faultit will isolate the system, blow the TRU CBs
    cuts side tie breaker closes bottom tie breaker to see if its a problem with the TRU or if a problem with the secondary bus then monitors for 7 seconds
    if still a fault will blow the fuse to isolate completely
  79. 79when are battery essential services usedif generator power is lost, and at least one TRUs fail
    an unknown source of smoke
  80. 80what are the switch movements for battery essential servicesbattery master on
    batteries off
  81. 81—