Test
DF05 Powder properties and their importance in pharmacy
Este test tiene tipos de pregunta que se abren en el reproductor de siempre.
Preguntas del test (10)
1Particles come in a [blank_start]variety[blank_end] of shapes so it is important to have a [blank_start]universal[blank_end] way to express particle size. Particle size is therefore described as the [blank_start]volume[blank_end] of the particle being equal to the volume of the [blank_start]equivalent sphere[blank_end], and then dv = [blank_start]diameter volume[blank_end]. For example the length x breadth x depth of a particle would be equal to [blank_start]4/3πr³[blank_end].
Particle size could also be expressed as ds; sphere of same surface area, dw; sphere of same weight, and many more.- Avariety
- Buniversal
- Cvolume
- Dequivalent sphere
- Ediameter volume
- F4/3πr³
2What kind of graph best represents the usual distribution of particle size?
- ABell curve
- BHyperbole
- CExponential
- DLinear with negative slope
3The smaller the particle sizes the greater the surface area.
- AVerdadero
- BFalso
4Particle size is decreased through granulation to improve flow properties.
- AVerdadero
- BFalso
5Flowabilty is an important bulk powder characteristic.
The angle of repose is the [blank_start]maximum[blank_end] angle possible between the [blank_start]surface[blank_end] of a pile of powder & the [blank_start]horizontal plane[blank_end]. It is an indirect method of quantifying flowability. [blank_start]0-25°[blank_end] is very good, [blank_start]25-40°[blank_end] is satisfactory, and [blank_start]>40°[blank_end] indicates bad flowability.- Amaximum
- Bsurface
- Chorizontal plane
- D0-25°
- E25-40°
- F>40°
6Choose the incorrect equation.
- ABulk volume = Particle volume + volume of spaces between particles (Vb = Vp + V)
- BVoid volume = Bulk volume - Particle volume (V = Vb - Vp)
- CPorosity = ε = Vb / V
7Choose the correct equation for bulk density, ρb.
- Aρb = m/Vb
- Bρb = Vb/m
- Cρb = m/Vp
- Dρb = Vp/m
8During tapping, particles gradually pack [blank_start]more[blank_end] efficiently, the powder volume [blank_start]decreases[blank_end] and the tapped density [blank_start]increases[blank_end].
- Amore
- Bless
- Cdecreases
- Dincreases
- Eincreases
- Fdecreases
9Carr’s compressibility index tells us the relationship between % compressibility and flowability. Carr’s index (%) = ([blank_start]Tapped[blank_end] density − [blank_start]bulk[blank_end] density) / [blank_start]Tapped density[blank_end], then X [blank_start]100[blank_end] to make it a percent. 1-15% compressibility indicates [blank_start]excellent[blank_end] flow, >40% compressibility indicates [blank_start]extremely poor[blank_end] flow.
- ATapped
- BBulk
- CTapped density
- DBulk density
- E100
- Fexcellent
- Gextremely poor
10Uneven powder flow could cause excess [blank_start]entrapped air[blank_end] within powders leading to [blank_start]capping or lamination[blank_end]. It could also increase particle’s [blank_start]friction[blank_end] with die wall, causing [blank_start]lubrication problems[blank_end] and increasing [blank_start]dust contamination[blank_end] risks.
[blank_start]transfer[blank_end]- Aentrapped air
- Bcapping or lamination
- Cfriction
- Dlubrication problems
- Edust contamination
- Ftransfer
- G.
Información
- Descripción
- (Formulation) PHCY211 Test sobre DF05 Powder properties and their importance in pharmacy, creado por Mer Scott el 28/04/2018.
- Autor
- Mer Scott
- Idioma
- English
- Visitas
- 7
- Etiquetas
- Valoración
- Aún sin valoraciones Valora este test