Test
Peripheral Intravenous Access
Este test tiene tipos de pregunta que se abren en el reproductor de siempre.
Preguntas del test (14)
1An indication for IV Access is Unintended Arterial Puncture
- AVerdadero
- BFalso
2Which is not a complication of IV Access
- APhlebitis
- BInfection
- CBurns
- DAir Embolus
- ECannula Shear
3A [blank_start]non vesicant[blank_end] solution is a drug/fluid which may cause irritation to surrounding tissue through to necrosis of the tissue.
- Anon vesicant
- Bvesicant
4Intravenous access should be implemented as soon as possible to avoid delays in administration of medications/fluids?
- AVerdadero
- BFalso
5What are two complications of IV Access?
- AExtremity on the same side as a mastectomy
- BNeeding fluid resuscitation
- CPhlebitis
- DAdministration of analgesic medications
- EHaematoma
- FAll of the above
6Which answer is the inflammation of a vein associated with thrombus formation?
- AThrombophlebitis
- BPhlebitis
- CDrug/Fluid Extravasation
7Air emboli entering the circulatory system is not a complication of IV Access.
- AVerdadero
- BFalso
8Veins of the metacarpal region are:
- AMedian Cubital, Basilic, Cephalic, Antebrachial
- BBasilic, Cephalic, Dorsal Venous Arch
- CGreat Saphenous Vein, Lesser Saphenous Vein, Dorsal Venous Vein
9All IV cannula should be re-sited how often?
- AEvery 24 hours
- BEvery 12 hours
- CEvery 48 hours
- DEvery 96 hours
- EEvery 72 hours
10Only 2 attempts to cannulate are recommended.
- AVerdadero
- BFalso
11IV access is an [blank_start]invasive[blank_end] procedure, therefore appropriate consideration must be given to its requirement in the pre-hospital setting.
- Ainvasive
- Buncomfortable
- Cpainful
- Dembarrassing
12IV Cannulas come in different sizes. How many sizes do QAS use specifically for IV access and what is the smallest size and the largest size?
- A5 sizes of cannula, smallest is 24 gauge and the largest is 20 gauge
- B6 sizes of cannula, smallest is 16 gauge and the largest is 24 gauge
- C5 sizes of cannula, smallest is 24 gauge and the the largest is 16 gauge
- D6 sizes of cannula, smallest is 14 gauge and the largest is 24 gauage
13QAS use 14 gauge cannulas for:
- ACannulating severely obese patients
- BFor rapid volume replacement and paediatric chest decompression
- CGeneral medication and/or fluid administration
- DAdult chest decompression
- EDifficult access/paediatric
14[blank_start]Extravasation[blank_end] is the leakage of a [blank_start]vesicant[blank_end] drug/fluid into the surrounding tissues and may cause irritation through to [blank_start]necrosis[blank_end].
- AExtravasation
- BInfiltration
- Cvesicant
- Dnon vesicant
- Enecrosis
- Fthrombophlebitis
Información
- Descripción
- Learning resource for paramedic students learning about peripheral intravenous access
- Autor
- jody.stroud
- Idioma
- English
- Visitas
- 666
- Etiquetas
- Valoración