Electrical Test 2

Jarmo Tossavainen 25 preguntas

Hacer el test

Preguntas del test (25)

  1. 11/ Which British Standard details the requirements for the correct installation of electrical components in domestic properties?
    1. Aa) BS 5449
    2. Bb) BS 6700
    3. Cc) BS 7671
    4. Dd) BS 8000
  2. 22/ Which of the following is the correct description of a spur circuit?
    1. Aa) Supply from the meter to a component
    2. Bb) Supply from the consumer unit to an immersion heater
    3. Cc) Branch connection from a ring main circuit
    4. Dd) Branch connection from a main earthing cable
  3. 3What component is used in a domestic property to house the circuit protection devices?
    1. Aa) Junction box
    2. Bb) Meter
    3. Cc) 13 amp socket outlet
    4. Dd) Consumer unit
  4. 4What type of component is shown in the following picture?Imagen de la pregunta 4
    1. Aa) RCBO
    2. Bb) RCD
    3. Cc) MCB
    4. Dd) Fuse
  5. 5What is the circuit breaker rating required to control the supply to an 8.5kW
    instantaneous electric shower fed with a 230v AC supply?
    1. Aa) 13 amp
    2. Bb) 16 amp
    3. Cc) 32 amp
    4. Dd) 40 amp
  6. 66/ A capacitor may be fitted to which of the following components?
    1. Aa) Jacuzzi pump
    2. Bb) Consumer unit
    3. Cc) Junction box
    4. Dd) Room thermostat
  7. 7Which of the following plumbing components in a domestic property will usually require a 2.5mm² heat proof flex?
    1. Aa) Electric shower
    2. Bb) Immersion heater
    3. Cc) Central heating pump
    4. Dd) Macerator WC
  8. 8Which of the following correctly lists the sheathing colour in a modern 3 core flex in this order Live-Neutral-Earth

    1. ABlue - Brown - Green and Yellow
    2. BYellow- Blue- Brown/Green
    3. CRed Brown Green/Yellow
    4. DBrown-Blue-Green/Yellow
  9. 9What is the name of the connector shown in the following diagram?Imagen de la pregunta 9
    1. Aa) Pillar terminal
    2. Bb) Strip connector
    3. Cc) Claw washer
    4. Dd) Terminal connector
  10. 10Knots and coils should not be left in cables during installation as they can lead to –
    1. Aa) Corrosion of the cable
    2. Bb) Reduction in resistance of the circuit
    3. Cc) Reduction in cable insulation
    4. Dd) Heating of the cable during use