¡GoConqr estrena diseño! Cuéntanos qué te parece.

Test

1995 State

Madison Feeler 46 preguntas

Hacer el test

Este test tiene tiempo límite, así que se abre en el reproductor de siempre.

Preguntas del test (46)

  1. 1What combination of switches may be used to control a light from four locations?
    1. AFour 3-way switches
    2. BTwo 3-way switches and two 4-way switches
    3. CThree 3-way switches and one 4-way switch
    4. DFour 4-way switches
  2. 2Which of the following is the standard length of electrical metallic tubing?
    1. A5 ft
    2. B10 ft
    3. C15 ft
    4. D20 ft
  3. 3According to the National Electric Code, which of the following colors are acceptable for the grounded conductor in a circuit?
    1. AGreen
    2. BAny color but black or red
    3. CBare
    4. DWhite or gray
  4. 4Which of the following is a cable type that would be appropriate to use in a barn where the conditions will be moist?
    1. ANM
    2. BGE
    3. CUF
    4. DTM
  5. 5An "ampere" is the measurement of the?
    1. AFlow of electrons through a conductor.
    2. BPush on the electrons in a circuit.
    3. CResistance to the flow of current.
    4. DElectrical power of the current.
  6. 6The major purpose of a ground-fault interrupter is?
    1. ATo protect equipment from damage due to overloading.
    2. BAs a replacement for fuses in homes.
    3. CTo protect humans from electrical shock due to a ground fault.
    4. DTO protect appliances in case of a natural disaster.
  7. 7When connecting the branch circuit wires within a panel board (circuit breaker box), it is common practice to place the white wire?
    1. AUnder the lug of the circuit breaker.
    2. BTo the terminal bar with the bare ground.
    3. CTo the neutral terminal bar.
    4. DUnder the lug of a fuse.
  8. 8According to the National Electric Code, when securing electrical cable to a wooden surface (ie. a stud), it is a safe practice to place ?
    1. AThe stable within 8 inches of a plastic device box.
    2. BThe staple within 12 inches of a plastic device box.
    3. CThe staple within 18 inches of a plastic device box.
    4. DThe staple within 13 inches of a plastic device box.
  9. 9Which of the following overcurrent devices are designed to handle a "surge" of power that would occur when a large electrical load is energized?
    1. ATime delay fuse
    2. BEdison base fuse
    3. CCircuit breaker
    4. DGFCI
  10. 10The largest breaker than can be used to safely protect a 12 gauge wire is?
    1. A15 Amp breaker.
    2. B20 Amp breaker.
    3. C30 Amp breaker.
    4. D12 Amp breaker.