O GoConqr está de visual novo! Conte para nós o que você achou.

Flashcards

Electrics - Studyguide questions

Ella Davies A320 TYPE PILOT Inglês 26 flashcards

Flashcards do conjunto (26)

  1. 1what is the max KVA for the GEN 1 and 290KVA
  2. 2what is the max KVA for the APU GEN?90 KVA
  3. 3What is the max KVA for the emergency Gen5 KVA
  4. 4if the BAT ob are left in the AUTO position over night without any other power, will the batteries discharge completely?an automatic cut off logic prevents the batteries from discharging completely
  5. 5how is the AC ESS Bus powered when the AC BUS 1 has failedAC BUS 2
  6. 6Which electrical system is more heavily loadedno 1 system
    - covers the Batt system too
  7. 7how is an IDG disconnected?maintaining teh IDG pb during more than 3s may damage the IDG disconnection mechanism
  8. 8what precautions must be taken when the engine IDG disconnected?only when the engine is running or windmilling
    otherwise the IDG will be damaged when starting the engine
  9. 9is TR 1 fails what supplied the DC ESS BUS?ESS TR supplies the DC ESS BUS
  10. 10what Hyd drives the emergency generator?The blue hyd system
  11. 11what causes the RAT to auto extend?If both AC 1 and AC 2 BUS disconnected and the IAS is above 100 kts
  12. 12if the RAT autoextension fails.. how is the RAT deployed?by the red guarded switch to man extend the RAT
  13. 13which busses are supplied by the EMERG GEN?AC ESS BUS
    DC ESS BUS
    AC ESS SHED
    DC ESS SHED
  14. 14On bat supply what busses get power ON bat 1?BAT 1
    HOT BUS 1
    STATIC INV
    AC ESS BUS
  15. 15On bat supply what busses get power ON bat 2?hot bus 2
    DC ESS BUS
  16. 16on bat only supply in flight, can the APU be started in flight?yes
  17. 17how long is the apu unavailable for after loss of both eng gens in flight?45s
    DELAY PREVETNS INTERFERENCE WITH THE EMERG COUPLING
  18. 18What is the FL limitation on starting the APUFL250
  19. 19What does a red switch mean?irreversible action
  20. 20what speed does the RAT stall?140 kts
  21. 21what happens when the GEN 1 LINE pb is selected off?GEN 1 contactor opens. AC BUS 1 is supplied from GEN 2
  22. 22when would the crew switch GEN line 1 off?Smoke drill, 1 fuel pump in each wing is powered by GEN 1
  23. 23how many colours/types of CBs are there?GREEN
    BLACK
    RED
  24. 24What is the significance of Green CBs?When out for more than 1 min, the C/B Triggered message appears on ECAM
  25. 25when in flight can you reset a CB?you should not reengage a circuit breaker unless necessary for the continuation of a safe flight
    only one attempt should be attempted
  26. 26what CBs can you absolutely not resetRED CBs

Informações

Descrição
PILOT A320 TYPE FlashCards sobre Electrics - Studyguide questions, criado por Ella Davies em 16-10-2023.
Criado por
Ella Davies
Visualizações
1
Avaliação

Fale Conosco

Sobre o que é sua mensagem?

O que você acha do novo visual?

Você gostou?