  1. 1Briefly define EEG.Electroencephalography is the recording of electrical activity/potential differences of the brain from the scalp, on the surface of the brain (intracranial), or within the substance of the brain (depth). It literally means 'A recording of w
  2. 2Describe the setup and machinery used to record Scalp EEG.Scalp EEG is measured by placing electrodes (small metal discs) on the scalp. Electrodes are placed at several points on the scalp to record potential differences across several paths. Potential differences are typically recorded with respect to a fixed reference electrode. The electrodes are usually fixed to the scalp with conductive glue.
    An EEG machine measures the potential difference between a given electrode and the reference electrode. This difference is usually amplified by an analog differential amplifier which is typically grounded to a point on the skin/scalp away from the signals of interest. Low-pass filtered is then used to prevent aliasing. Sometimes high-pass DC filtering is used to make the EEG signals easier to analyse by visual inspection, by enabling the inspector to see all channels over a given window at the same time. Additional gains or amplifications may be used, and then the potential difference is converted into a digital signal using an analog-to-digital converter. Common conversion sampling rates for commercial EEG machines are on the order of 200-512Hz..
  3. 3Use diagrams to help you.Use diagrams to help you.
  4. 4Describe the sources within the brain that are most responsible for generating the scalp EEG1. Parallel sources generate a much greater EEG than randomly oriented ones.
    2. Synchronous sources generate a much greater EEG than asynchronous ones.
    In the brain the only place that has parallel sources is the cortex. Thus the cortex is the region of the brain most responsible for the EEG waveforms we observe at the scalp. This does not mean that other (deeper) parts of the brain are inactive, it only means that the EEG measurement at the scalp is mostly ignoring their contributions.
  5. 5Comment on how the properties of the material surrounding the brain can affect the measurementThe materials surrounding the brain affect the EEG recording in two ways:
    1. Introducing artefact: Many of the muscle movements and blood flow surrounding the brain can be recorded by the EEG.
    2. Shaping the recorded signal: Remember that a signal must travel through the materials surrounding the brain to reach the recording location. These materials have electrical properties that affect the signal. The effects of the different tissues can be summarised by Green's function (See lecture notes). Greens function takes into account distances, electrical properties, and the way the materials are physically arranged (e.g. layers of different materials).
  6. 6If you wanted to find out where in the brain an epileptic patient had most of their seizures, how could you use scalp EEG to find out?To find a seizure focus using EEG one usually begins by using a scalp EEG recording, where electrodes are placed all over the scalp surface. Usually when a patient has a seizure several of these channels will show signature patterns involving oscillations on the order of 3-10Hz. Hopefully one electrode will consistently represent the onset of the seizure, indicating the focus is nearby.
  7. 7Why could you have problems finding the seizure focus using just scalp EEG?Sometimes it is hard to determine the seizure focus from scalp EEG because several electrodes start showing the seizure at the same time, on the same or opposite sides of the brain. This is because the scalp EEG records very large areas of brain activity.
  8. 8If you couldn’t find the seizure focus with scalp EEG, what would you do?To try and get a better idea of the seizure focus, intracranial grid or depth electrodes can be used to record signals in the region containing the seizure focus. This enables the recording of signals much closer to the seizure source, which gives much better signal-to-noise ratio as well as increased spatial resolution.
  9. 9Describe the difference between an electric dipole and a current dipole.An electric dipole is the combined electric field generated between 1 positive and 1 negative charge. A current dipole is the combined electric field generated between 1 current source and 1 current sink. Mathematically, the fields generated by an electric and a current dipole are very similar (see lecture notes).
  10. 10Make reference to the modelling of EEG measurement, and why the latter is more convenient than the former.To model the EEG using electric dipoles requires knowledge of the location (or at least the distribution of) all the charges in the head. Furthermore, when using equivalent electric dipoles it is hard to know whether the assumption that there is roughly an equal number of positive and negative charges within a volume is true.
    In contrast, the activity of ion gates that open to allow charges through the membrane of neurons can be approximated as current sources and sinks. We know a lot more about the distribution of ion gates in the brain than we do about the distribution of individual charges. When we use an equivalent current dipole to represent the average activity within a small volume of cortex we know that physiologically there are roughly an equal number of current sources and sinks within it. This, coupled with other statistical knowledge we have about the physiology of the brain (and the cortex in particular) makes the use of current dipoles advantageous when modelling the EEG.

Informações