O GoConqr está de visual novo! Conte para nós o que você achou.

Flashcards

VENTILATION study guide

Ella Davies A320 TYPE PILOT Inglês 29 flashcards

Flashcards do conjunto (29)

  1. 1what range of temps can the compartments be set to?18 -30 C
  2. 2What is the COLD position?18 C
  3. 3What is the HOT position?30 C
  4. 4how are the zone temperatures controlledby the trim air valves
  5. 5what controls the packs?ACSC 1 & 2
  6. 6What modulates the trim air valvesACSC 1 & 2
  7. 7What 3 conditions cause the pack flow to be higher than the selected on the overhead panel?- in single pack flow - HI
    - When the APU is supplying bleed air, PACK FLO high
    - If LO flow is selected but the temperature demand cannot be met (so MED is selected to meet temp demand)
  8. 8what happens to the PACKS during engine start?PACK valve closes automatically
  9. 9what happens to the PACK flow if the APU is supplying bleed air to both packsPACK flow goes to high
  10. 10when does the pack ram air inlet flap close automatically?during take off - when TO power sets and landing gear struts are compressed
    During Landing - when landing gear struts compress if speed is at or above 70 kts
  11. 11when do the pack ram air inlet flaps close automatically?On lift off
    20 seconds after the speed drops below 70 kts
  12. 12what happens when the RAM air pushbutton is selected ON?emergency ram air inlet opens
  13. 13what happens to the opening of the ram air inlet valves when delta P over 1 psi ?= the outflow valve control remains normal, no emergency ram
  14. 14what happens to the opening of the ram air inlet valves when delta P less than 1 psi ?outflow valve opens to about 50 % when under auto control
  15. 15what happens when ACSC 1 has a double-lane failure? VALVES REMAIN IN THE POSITION THEY WERE IN WHEN THEY FAILEDPACK FLOW CONTROL VALVE 1 - CLOSE
    PACK 1 - FAIL, PACK 2 - HIGH
    HOT AIR PRESS REGULATOR VALVE - CLOSE
    ALL TRIM AIR VALVES SHUT
  16. 16What happens if ACSC 2 has a double lane failure? VALVES REMAIN IN THE POSITION THEY WERE IN WHEN THEY FAILEDPACK FLOW CONTROL VALVE 2 CLOSES
    PACK 2 FAIL - PACK 1 HIGH
    CABIN AFT AND FWD TRIM AIR VALVES CLOSE
  17. 17What does ACSC stand for?Air conditioning System Controller
  18. 18what happens when a duct overheat occursHOT AIR PRESS regulating valve closes
    All Trim air valves close
  19. 19what is the Outflow Valve position when the AC is on the ground?OPEN
  20. 20what is the Outflow Valve position during take off?CLOSE
  21. 21what is the cabins rate of climb when the AC is in the climb out?Same rate as the AC rate of climb
  22. 22During Cruise what is the cabin alt?AC level off altitude
    or landing field elevation
    WHICHEVER IS HIGHER
  23. 23what is the cabins rate of descent when the AC is descending?AC rate of descent
  24. 24what is the Outflow Valve position after landing?55 s after landing the outflow valve fully opens, 500ft/min
  25. 25What is the max cabin alt in the cruise?8000 ft
  26. 26when is the ram air pushbutton used?in the event of a depressurisation as its bypasses the airconditioning unit
  27. 27how many valves can drive the OFV?3
    x2 automatic
    x1 manual
  28. 28CPC?CPC?
  29. 29If a pilot suspects that the selected CPC is malfunctioning, how can the pilot change CPC manually?MODE SEL - MAN
    wait 10 seconds
    RETURN TO AUTO