Flashcards
Experimental Techniques Controls
Flashcards do conjunto (23)
- 1Electron MicroscopyNegative Control - omission of primary AB, is anything picked up?
Any dynamic event should have inhibited controls. Inhibit the event, can something still be seen? - 2Fluorescence MicroscopyPositive Control - helpful to compare labelling of a cell type known to express a given protein to ensure that lack of labelling in a test sample is not due to failure of the labelling technique/ insufficient detection sensitivity
similarly, in dynamic studies looking for movement or change in fluorescence properties, a suitable positive control may be a treatment known to result in a detectable change
Negative Control - discrimination of multiple fluorescent signals - may be necessary to perform controls to ensure that there is no overlap in signals generated by the probes - 3Intracellular Sharp Electrodethe article should directly show/cite earlier work that the preparation behaves 'normally' over the period of time that experiments are performed
article's methods section should specify a criteria for accepting a microelectrode recording - 4Patch Clampif drugs are used to inhibit ion channels that are not the focus of the study, care should be taken to ensure that these drugs do not alter the behaviour of the ion channels that ARE the focus of the study
IT IS TOO OFTEN ASSUMED THAT DRUGS HAVE A GREATER SPECIFICITY THAN IT IS SAFE TO ASSUME
on approach is to use 2 drugs that have selectivity for a given target. if the results of these experiments are equivalent, then it is less likely that they have unintended effects on the ionic current of interest - 5Antibodiesspecificity of primary AB - usually established using immunochemical techniques (immunoblotting, immunoprecipitation) before carrying out immunocytochemistry and immunohistochemistry
positive controls - transfected cells that express a high concentration of the investigated protein +/or tissue obtained from transgenic animals, which lack the target antigen
primary AB should be pre-absorbed with excess of the corresponding antigenic peptide or protein --> under these conditions all immunoreactivity should disappear --> control will show that the antibody binds to the antigen (doesn't exclude the possibility that it doesn't bind to anything else) - 6Immunohistochemistry + ImmunocytochemistryBEFORE - to confirm the specificity of the primary AB interaction with the target antigen using immunochemical techniques (immunoblotting/immunoprecipitation) before it is used for immunohisto --> a well-conducted study will either do this or refer to other studies to provide the necessary validation
negative control - omitting the primary AB checks the specificity of various immunolabelling procedures
it is often very helpful to use two different ABs raised against different epitopes of the same peptide or protein for localisation studies. if patterns are of staining are same with both ABs, this is strong circumstancial evidence in favour of specificity
ideal control sample is tissue obtained from a transgenic animal that lacks the target antigen - 7Immunoprecipitationpre-clearing - to reduce non-specific binding of proteins, the lysate is pre-treated with a mixture of protein A/G and agarose beads in the absence of any primary ABs
negative controls- controls for non-specific binding should be used to show that the proteins being precipitated reflect the specific interaction between primary AB and antigen:
a cell line/knockout that does not express the antigen as a negative control
a cell lysate in which the target is known to be expressed as a positive control
input control - strength of the band depends ultimately on the amount of protein available in the lysate, this can vary between otherwise identical experiments, must measure and control protein content - 8Immunoblottingremoving or denaturing the primary AB - does the band go away?
negative control - is there a signal from cells known NOT to express the protein of interest?
positive control - is the band seen using a cell or tissue that is known to express the protein?
verification - protein band is removed and identified by mass spec - 9Green Fluorescent Proteinthe expression of GFP-labelled proteins in cells to study the localisation and dynamics of proteins relies on GFP-labelled protein chimeras behaving like native proteins -->
researchers may knock-out endogenous protein expression and then show that its function is substituted by the expression of a GFP-labelled version
negative control - accumulation of GFP-labelled protein in a particular compartment may be verified by negative controls -->
here, cells are transfected with a similar plasmid with a modified GFP construct that should not show similar enrichment in the cellular compartment - 10Fluorescence Resonance Energy Transferpositive control - must compare with a protein pair/ physically linked donor/acceptor is presented
negative control - compare with signal from a similar pair of proteins where the fluorophores don't interact - 11Fluorescent Measurement of Ion Activity in Cellsappropriate calibration technique for calibrating the signals to minimise contamination by these signals
must take into account autofluorescence and background fluorescence
important to know the affinity (Kd) of the dye for the ion and though known in saline, the Kd may substantially change in the intracellular environment - 12Viral Vector Transgenesisthe use of any VV in a novel context (not in a previously studied tissue/area/cell type/age group/species) requires that the authors have successfully validated their approach by confirming successful transgender expression in the cells of interest by independent means such as immunohistochemistry
- 13Polymerase Chain Reaction and Reverse Transcription-PCRnegative controls - 'no primer' / omission of DNA polymerase to control for background fluorescence/ omission of reverse transcriptase to control for contamination (lookup)
positive controls - to ensure that a lack of PCR product is a true negative result rather than a failure of the process --> diluted plasmids containing the cDNA of interest BUT need to be kept separate from experimental samples, in a different lab, to ensure that cross-contamination doesn't occur - 14In Situ Hybridisationnegative controls - hybridisation of the tissue with a 'sense' probe (probe of the same) as opposed to complementary --> control for non-specific binding to the tissue due to something in that specific sequence (chemistry of the probe) --> can then be sure the signal detected with your antisense probe is due to sequence-specific binding to mRNA and not due to binding other targets within the cell
pre-digestion of RNA - to demonstrate that signal is associated with binding of the probe to RNA in the tissue
multiple probes - aimed at different parts of the same target --> should show that all probes have the same distribution of signal
positive control - perform ISH with correct oligonucleotide probe on a tissue known to have the sequence of interest --> if you detect no signal, then this suggests the problem exists with your technique/protocol
ABSENCE OF EVIDENCE (=/) EVIDENCE OF ABSENCE - 15Microarrays - Transcriptome Analysisneed replicates --> required to account for
1) variations in the biology
2) technical aspects of the experiment
--> that cannot be adequately be controlled for within the experiment
careful NORMALISATION - with appropriate multiple test comparisons is critical for minimising false results in array experiments
without appropriate normalisation, the data may represent experimental noise --> ensures that any technical (background signal between two arrays) or uncontrolled (different experimental batch) aspect of the experiment is removed from the data
--> SO THAT THE DIFFERENCES THAT REMAIN RESULT FROM THE TREATMENT UNDER STUDY - 16In Vivo Experimental Proceduressame experiment but without treatment
same experiment but with knockout mice
double blind treatments - both experimenter and animals blind to the treatment and allocation of treatment ( experimenter most prominent in animal behaviour models) - 17Genetically Modified Mouse Models - Transgenic Techniquesimportant to demonstrate that the phenotype (physiological appearance/behaviour) of the animal is a consequence of the expression of the transgender construct itself and NOT the insertion of the construct into a specific genomic locus
to confirm 'insertion-independence' expression of a transgene --> one needs to demonstrate that 2 (or more) different lines of transgenic mice have identical phenotypes
if a phenotype of the 2 lines is identical, it must be an effect of the transgene expression, not a consequence of its location/expression level
ALWAYS CHECK WHETHER THE AUTHORS HAVE COMPARED MULTIPLE LINES OF TRANSGENIC MICE - 18Genetically Modified Mouse Model - Embryonic Stem Cell Techniqueif the aim is to delete a gene or insert a particular mutation in a gene, the authors must demonstrate that the gene function is indeed, altered in the resulting animal
--> a strategy for testing the function of this gene must be described - 19Genetically Modified Mouse Model - Cre/loxP Systemboth mice must be 'normal' (i.e. unaffected by their genetic alteration)
it is essential that the authors demonstrate appropriately the deletion/dysfunction of the gene of interest - 20Electrical Stimulation Methodscharacterisation of the threshold current and optimal parameters of stimulation are important in establishing the specificity of the response and enabling comparison with other studies
in the case of brain stimulation --> the location of the stimulation site should be confirmed histologically - 21Extracellular Recordingin order to interpret the recorded neuronal activity, it is essential to know the location of the recording
glass electrodes --> fill the micropipette with dye which is then ejected into the surrounding tissue at the end of the recording
metal electrodes --> the recording position can be marked by passing current through the electrode to make a small lesion
DYE/METALLIC DEPOSIT/ LESION - 22Axonal Transport Tracingelectrophysiological identification - of neutrons (by their response properties) at an injection site necessary if the borders containing the neutrons are poorly designed
different tracers - tracers vary in their propensity for uptake, axoplasmic transport properties and sensitivity for detection --> replicating with a different tracer is often desirable --> same result? - 23—