Walls - DPCs & Cavity Walls

  1. Act as a barrier to the passage of moisture or water between the parts separated by the DPCs

  2. Requirements

    • should be continuos for the whole length and thickness of the wall
    • at least 150mm above finished ground level
  3. Types

    • Flexible
    • Semi-rigid
    • Rigid
  4. Modern DPCs

    • separate DPC for each leaf
    • most made from polythene
    • co-polymer thermophastic is now used
    • all laps and joints sealed by >100mm using double sided jointing tape
  5. Bitumen Felt DPCs

    • traditional material is used for DPCs
    • extrude under pressue when loaded
    • can become brittle when exposed to UV light
    • minimum moisture capillarily in walls
  6. Polyethylene DPCs

    • inexpensive DPC material that does not extrude under load or suffer from UV embrittlement
  7. Cavity Walls

    • first proposed in early 19thC. developed through 20th
    • Resistance to weather & ground mositure
    • Thermal insulations
    • Strength & Stability
    • Regulations
      • min width of 50mm
      • kept clear of mortar snots
      • can be full or partially insulated
      • for full insulation, a clear cavity of 50mm should be provided
    • Internal walls
      • fully filled
      • provide a better u - value
      • Insultion fitted snug into the cavity the internal wall is kept dry/warm; less susceptible to degradation and moisture
    • External walls
      • requires careful attention to spec & finishing
      • fully filled- any ingress of moisture will dampen wall and insulation
    • Cavity wall ties
      • Functions
        • provide a connection
        • transfer lateral load
        • permit in-plane movement to accomodate differential movements
        • connect 2 leafs together to provide better restraint against transverse and lateral loads
        • provide strength and stability
        • Act in TENSION as TIES
        • Act in COMPRESSION as STRUTS
      • Spacing
        • 450 x 900mm
      • Positioning
        • bedded 50mm into mortar joints in each leaf
        • slight fall to outer leaf