Quiz
Sem título
Crie uma conta grátis para terminar este quiz
Salve seu progresso e veja sua nota final.
Já tem uma conta? Inicie sessão
Perguntas do quiz (73)
1When upgrading a standalone Cisco UCS C-Series server, which method is correct?
- Adirect upgrade on all components
- BCisco Hardware Upgrade Utility
- CCisco Host Upgrade Utility
- D Cisco Server Upgrade Utility
2In a standalone Cisco UCS C-Series server, which recommendations can be used to upgrade the BIOS?
- ACisco IMC
- BCisco UCS Manager
- CiFlash32 Utility
- DFlash ROM Utility
- E EFI Interface
- F Cisco Host Upgrade Utility
- GUSB Flash Utility
3What are the default settings of the Cisco IMCCIMC NIC properties on a standalone Cisco UCS CSeries server?
- A'Shared LOM' NIC mode with 'Active-active' NIC redundancy and DHCP enabled
- B 'Shared LOM' NIC mode with 'Active-standby' NIC redundancy and DHCP enabled
- C'Dedicated' NIC mode with 'Active-standby' NIC redundancy DHCP disabled
- D 'Dedicated' NIC mode with 'None' NIC redundancy and DHCP enabled
- E'Cisco Card' NIC mode with 'Active-active' NIC redundancy and DHCP enabled
4 Which ports can access the Cisco IMC if you select Shared LOM NIC mode in the Cisco IMC Configuration Utility for a Cisco UCS C-Series server?
- Athe ports on an installed Cisco network adapter card
- Bthe two 1-Gb Ethernet ports
- Cthe two 10/100 management ports
- D the two 10/100 management ports, but each port has a default setting
5Which NIC redundancy modes allow the LOMs to be discovered by the operating system or hypervisor?
- ADedicated mode
- BActive/Active
- C Active/Standby
- DCisco Card Mod
6Which two are true with respect to the unified ports on the Cisco Unified Computing System 62XX Fabric Interconnect? (Choose two.)
- AThe port mode is automatically discovered after plugging in a LAN or Fibre Channel-attached cable
- BBy default, unified ports that are changed to Ethernet port mode are set to uplink Ethernet port type.
- CEthernet ports must be grouped together in a block and must start with the first port and end with an odd numbered port.
- DAlternating Ethernet and Fibre Channel ports is supported on the expansion module.
- EAfter making port mode changes on an expansion module, the module will reboot.
- FIn a standalone configuration, making port mode changes to the fixed module will not cause the fabric interconnect to reboot
7Which two are true with respect to the switching modes on the Cisco Unified Computing System 62XX Fabric Interconnect? (Choose two.)
- AEnd-host mode presents a link to a northbound uplink switch as a host trunk with loop detection that is provided by STP.
- BFor northbound traffic, server MAC addresses are statically pinned to an uplink; the return path is controlled by the unified fabric switches.
- CA fabric interconnect port in Ethernet switching mode appears to the uplink switch as a host with many MAC addresses.
- DServer-to-server traffic on a common VLAN are locally switched by the fabric interconnect and not the northbound switches.
- E A MAC forwarding table is not used to forward traffic to the uplink switch.
- FA MAC address forwarding table is maintained for server-to-server communications across VLANs.
8What is true statement concerning port personalities on the Cisco Unified Computing System 62XX Fabric Interconnect?
- A Fibre Channel uplink ports must operate in Fibre Channel switching mode.
- BThe fabric interconnects use native FCoE storage ports to directly attach to the SAN infrastructure.
- CBy default, all Fibre Channel ports are unconfigured.
- DThe Fibre Channel uplink ports do not support VSAN trunking and Fibre Channel port channels.
- EThe Fibre Channel storage ports support VSAN trunking and Fibre Channel port channels.
9What is a true statement concerning automatic Fibre Channel pinning on a Cisco Unified Computing System 62XX Fabric Interconnect?
- ABy default, uplink Fibre Channel interfaces are configured for VSAN trunking.
- BUsing NPV, each downstream server will be pinned to an uplink port that is based on a PIN group.
- CThe Fibre Channel pinning process is implemented differently than end-host MAC address pinning.
- DWith VSAN trunking, the automatic pinning of server traffic to Fibre Channel uplink ports will be based on the server WWN.
10The Cisco UCS administrator has the chassis discovery policy set to "2-link". The administrator connects a new chassis to the Cisco UCS 6200 Series Fabric Interconnects using four links. Which option about link utilization is true?
- AThe Cisco UCS will use two links until the chassis is reacknowledged, after which it will use all four links.
- BThe Cisco UCS will use all four links for discovery.
- CThe Cisco UCS will use only two links. The other two links are unusable.
- DThe Cisco UCS will use only two links. However, the administrator can manually pin traffic to the extra links by using service profiles.
11Which policy is used to update adapter firmware?
- Aadapter policy
- Bhost firmware policy
- Cmanagement firmware policy
- Dnetwork control policy
12Which options are valid port types when configuring fixed 10-Gb LAN interfaces on the Cisco UCS 6200 Series Fabric Interconnects? (Choose three.)
- Amonitoring port
- Bserver port
- Cuplink Ethernet port
- DFEX port
- E Fibre Channel storage port
13When cabling a Cisco UCS 6200 Series Fabric Interconnect to disjoint Layer 2 networks, which option must be considered?
- AThe fabric interconnect must be in switching mode.
- B You must first configure a LAN pin group.
- CEach VLAN is allowed across multiple disjoint uplinks
- DEach vNIC can communicate to a single disjoint network.
14Which two items represent the features of Call Home on the Cisco Unified Computing System? (Choose two.)
- Asyslog
- Bsend fault details to Cisco TAC
- C SNMP trap receiver
- D send email alerts to administrators
- E central repository of normalized fault data
15Which three items represent message formats that are available to send fault data using Cisco Call Home? (Choose three.)
- Ashort text
- Blong text
- CHTML
- DSOAP API
- EXML
- FJava
16Which item describes the failure scenario called a "split-brain" in the Cisco Unified Computing System?
- Afailure of the Cisco Unified Computing System L1-L2 network
- B failure of a Cisco Unified Computing System Chassis Management Controller
- C failure of a Cisco Unified Computing System I/O module
- Dfailure of a Cisco Unified Computing System Fabric Interconnect
- E failure of a Cisco Unified Computing System Chassis Management Switch
17Which two are true concerning the role-based access control specifics of a Cisco Unified Computing System? (Choose two.)
- ADisabled local user accounts are deleted from the database
- BA locally authenticated user account is any user account that is authenticated through LDAP, RADIUS, or TACACS+.
- CIf a user maintains a local user account and a remote user account simultaneously, the roles that are defined in the local user account override those that are maintained in the remote user account.
- DBy default, user accounts expire after 90 days; a warning message will be generated 10 days prior to expiration.
- EA user that is assigned one or more roles will be allowed the privileges that are consistent across all of the assigned roles.
- FAll roles include read access to all configuration settings in the Cisco Unified Computing System domain.
18Which two are true concerning authorization within a Cisco Unified Computing System? (Choose two.)
- AA role defines a collection of privileges that determines which actions a user can take in Cisco Unified Computing System Manager.
- B Authorization consists of three components (roles, password policy, and locales) that are based on which features and resources the user will not have access to.
- C Customized roles can be configured on and downloaded from remote AAA servers.
- DThe logical resources, pools and policies, are grouped into roles.
- EIf the service profile cannot find available resources, it will search in the parent organization for pools and resources.
19Which two are true with respect to the upgrade process for the Cisco Unified Computing System? (choose two.)
- AFor easier manageability, Cisco provides one full bundle that contains the firmware images for all Cisco Unified Computing System components.
- BYou can choose from FTP, TFTP, SCP, and HTTP to copy the bundle image from a remote file system.
- CWhen the bundle image is downloaded, it must be transferred to the flash file system of the active fabric interconnect.
- DWhen the download is successful, Cisco Unified Computing System Manager expands the individual files from the archive and installs them in the correct flash file system partition
- EIt is strongly recommended that you activate all components in all chassis at one time
- FThe I/O module, CIMC, and adaptors update process operates strictly on the backup partition of Flash for a given component.
20Which Cisco UCS firmware are contained in the Cisco UCS Infrastructure software bundle? (Choose three.)
- ACisco UCS BIOS
- BCisco UCS fabric interconnects firmware
- C Cisco UCS adapters
- D Cisco UCS Manager
- ECisco I/O module firmware
- FCisco IMC
21Which Cisco UCS Manager feature allows you to specify multiple LDAP servers for user authentication?
- ARealm
- BLDAP Provider Group
- CAuthentication Domain
- DOrganization
22Which UCS components firmware are contained in the UCS Infrastructure software bundle?
- AUCS BIOS
- BUCS Fabric Interconnects
- CUCS Adapters
- DUCS Manager
- E IO Module
- FCisco IMC
23Which backup option must be used for a system restore?
- Afull state
- Ball configuration
- Csystem configuration
- D logical configuration
- Eincremental
24Which protocol is not supported for Cisco UCS backups and imports?
- AFTP
- BTFTP
- CSCP
- DSFTP
- EHTTP
25Which two items can you provision in a vHBA Template? (Choose two.)
- AMax Data Field Size
- BSCSI I/O Queues
- CFCoE VLAN
- DvHBA Interrupt Mode
- EStats Threshold Policy
- FFLOGI Timeout
26Which option describes the possible result of a customer configuring a server pool that contains Cisco UCS B200 M2 and B250 M2 blades?
- AA service profile cannot migrate automatically from one blade to another blade within the server pool due to hardware failure.
- BYou must decommission a blade server for the associated service profile to migrate to another blade in the server pool successfully
- CYou must uncheck the Restrict Migration box in the service profile to allow service profile migration between blades in the server pool.
- DAfter service profile migration, the server fails in boot from SAN due to differences in PCI device IDs.
27Which two options occur when a server discovery policy is invoked? (Choose two.)
- Aexecutes the qualification in the server discovery policy against the server
- Bapplies the scrub policy to the server
- C analyzes the inventory of the server
- D assigns the server to the selected organization, if configured
- Ecreates a service profile for the server with the identity burned into the server at time of manufacture
28If a customer wants to maximize the capability of server mobility with the Cisco UCS deployment, what two options are Cisco recommended? (Choose two.)
- A Configure a server inheritance policy.
- B Configure a Virtual Media boot.
- C Configure a hardware-based service profile with burned-in addresses and identities.
- D Configure boot from SAN.
- EConfigure service profiles with resource pools.
29You have a Cisco UCS B200 M2 server configured with 12 4-GB DDR3 1333-MHz dual-voltage memory DIMMs. You learned that the server memory speed is running at 1066 MHz instead. How can you configure the server to run at maximum memory speed?
- AYou cannot configure memory speed of 1333 MHz. The maximum memory speed of a Cisco UCS B200 M2 server with 12 4-GB DIMM is 1066 MHz.
- BMemory speed of the ESX host is configurable on VMware vCenter
- C Create a BIOS policy. In the RAS Memory BIOS settings, select Performance Mode for LV DDR Mode
- DOn the CIMC of the Cisco UCS B200 M2, select 1333 MHz in the Memory Speed option
30Your systems engineer has determined all of the firmware versions that the server operating system supports. What steps are taken on Cisco UCS to avoid manual firmware upgrades on the blade servers?
- AUse Cisco UCS Manager firmware management to upgrade all Cisco UCS blade servers to the same target firmware versions.
- BConfigure host firmware package and management firmware package policies and associate the firmware policies with the service profiles.
- CCreate a BIOS policy and define the host firmware package and management firmware package.
- DConfigure host firmware package and management firmware package policies and associate the firmware policies with the server pools.
31When you create a vHBA, what will you achieve by enabling persistent binding?
- AThis feature allows the binding of the SCSI targets to the vHBA, even across reboots.
- BThis feature allows the binding of the same WWPN from the pool to the vHBA, even across reboots.
- CThis feature allows the binding of the same WWNN from the pool to the vHBA, even across reboots.
- D This feature allows the binding of the Fibre Channel uplink to the vHBA, even across reboots.
32Which two tasks enable jumbo frames on a Cisco UCS system? (Choose two.)
- AIn the LAN cloud on Cisco UCS Manager, configure MTU 9000 in the uplink interfaces.
- B In the LAN cloud on Cisco UCS Manager, enable jumbo frames in Fabric A and Fabric B.
- C In the LAN cloud on Cisco UCS Manager, configure MTU 9000 in the VLAN.
- D In the LAN cloud on Cisco UCS Manager, define a QoS system class with MTU 9000.
- EIn the service profile, configure MTU 9000 in the vNIC.
- FIn the service profile, configure MTU 9000 in the virtual machine.
- G In the service profile, configure MTU 9000 in the uplink interfaces.
33Which three items represent some of the components to implement Cisco VM-FEX for Cisco Unified Computing System Manager B-Series blades? (Choose three.)
- ACisco VSM VM
- BVEM installed on the VMware vCenter server
- CVEM in the VMware ESX or ESXi host
- DCisco Unified Computing System Manager version 1.2 or higher
- EVMware vCenter server
- FFibre Channel VMFS volume
34Which three items represent some of the features that can be defined in a Cisco Unified Computing System Manager port profile? (Choose three.
- AQoS policy
- BACL
- CNetFlow
- D port security
- Enetwork control policy
- F VLAN or VLANs
35Which three items must be configured in the Port Profile Client in Cisco Unified Computing System Manager? (Choose three.)
- Aport profile
- BDVS
- Cdata center
- D folder
- E VMware vCenter IP address
- F VM port group
36If there are four I/O module links from the Cisco Unified Computing System 5108 Blade Chassis to the Cisco Unified Computing System 6248UP Fabric Interconnect, which dynamic vNICs can be defined?
- A9
- B16
- C24
- D48
- E54
- F112
37Which two of the listed BIOS options are required for VM-FEX in high performance mode? (Choose two.)
- ARSS
- Binterrupt coherency
- Cvirtualization technology
- Dcache validation
- EATS support
38When adding a VMware ESXi host to the Distributed Virtual Switch, what are two risks of migrating a VMNIC that is associated to vSwitch 0? (Choose two.)
- A loss of access to the management IP interface
- B duplicate IP address error
- C duplicate MAC address error
- Dloss of VMware ESXi communication with VMware vCenter
- EDVS port group will not appear in the VM network settings
- F DVS port group will overwrite the port groups in vSwitch 0
39Which VMware ESXi 5.0 CLI command will validate PassThru interfaces when they are available?
- A vem status -v
- B vempassthru-v
- C vemintf -v
- D vemifconfig -v
- Evempts -v
40Which three items are supported operating systems of the Cisco VM-FEX universal passthrough? (Choose three.
- AOracle Solaris 1
- BRed Hat Enterprise Linux 6.0
- C Microsoft Windows Server 2003 SP3
- DMicrosoft Windows Server 2008
- EUbuntu Server 12.2
- F SLES 11
41Which two VMware features must be turned off in the data center cluster for Cisco VM-FEX universal passthrough to operate? (Choose two.)
- AVMCI
- BDRS
- CFT
- DHA
- EvMotion
42Which two VMware features will not allow an adapter to transition from Cisco VM-FEX standard mode to universal passthrough mode? (Choose two.)
- A VM Snapshot
- BVolume Shadow Copy
- C Storage vMotion
- D HA
- E Resource Reservations
43Which BIOS setting is required for a VMware ESXi 5.0 host to support Cisco VM-FEX universal pasthrough mode?
- AVT for Directed IO
- B ACPI 10 Support
- CVEMDPA Agent
- D Execute Disabled Bit
- EProcessor C State
44What are the three main components of the VM-FEX environment? (Choose three.)
- A Red Hat Network Satellite server
- BESX host with Cisco UCS M81KR VIC
- C ESX host with Cisco UCS M72KR CAN
- D VMware vCenter
- E VMware Update Manager
- FCisco UCS Manager
- G Cisco VSG
45Which two policies can be configured in a port profile for VM-FEX high-performance mode? (Choose two.)
- AQoS Policy
- Bnetwork control policy
- Cadapter policy
- DBIOS policy
- E vNIC connection policy
46Which three options are true regarding port profiles in Cisco UCS Manager? (Choose three.)
- A Port profiles define operating-system kernel parameters.
- BPort profiles are represented as a port group in vCenter.
- CPort profiles can be used by more than one DVS
- DPort profile parameters are visible on vCenter
- E Port profile parameters can be modified from vCenter.
- FPort profiles can be modified only from Cisco UCS Manager.
47Which two options are valid modes for VM-FEX in a Cisco UCS Manager port profile? (Choose two.)
- Atransparent
- Bbypass
- Cstandard
- Dadvanced
- Ehigh-performance
- Flow-pass
48Which two elements are defined in a dynamic vNIC connection policy? (Choose two.)
- A adapter policy
- B QoS policy
- Cnetwork control policy
- Dnumber of dynamic vNICs
- E jumbo frame size
49Which adapter is capable of supporting VM-FEX?
- AVIC 1280
- BCisco UCS M61KR-I
- C Cisco UCS M72KR
- D Cisco UCS M51KR-B
50Which item represents a secure method of transmitting fault data with Cisco Call Home?
- A IPsec
- BSSL email
- Csecure XML
- DCisco Transport Gateway
- ERSA Digital Certificate
51Which item is required for communication between Cisco Unified Computing System Manager and VMware vCenter?
- A VeriSign Digital Certificates
- BRSA Digital Certificates
- CCisco Unified Computing System Manager Extension Key
- D VeriSign Plug-In
- EWMware vCenter Certificate Services
52How many certificates does Cisco Unified Computing System Manager have to export to communicate with VMware vCenter server if the VMware ESXi hosts are all running version 5.0 or higher?
- A1
- B2
- C4
- D8
- E16
53What is the purpose of the maximum ports that are filed in the port profile?
- Adetermines the maximum number of uplinks that VMs can use
- Bdetermines the maximum number of VMs that can use the DVS
- Cdetermines the maximum number of DVSs that can use the port profile
- Ddetermines the maximum number of dynamic vNICS on the DVS
54What is the maximum number of ports on a VMware vCenter Distributed Virtual Switch?
- A64
- B128
- C1024
- D4096
- E8192
55In the Create Dynamic vNIC Connection Policy dialog box, there is a configurable field titled Protection. What is the significance of the three choices for Protection?
- A allows reserve vNICs to be allocated out of the spares pool
- Benables hardware-based failover
- Cenables static binding of the VM port profile to dynamic vNICs
- Dselects the primary fabric association for dynamic vNICs
- E allows dynamic vNICs to be reserved for fabric failover
56How does a dynamic vNIC get allocated?
- ADynamic vNICs are assigned to VMs in VMware vCenter.
- BDynamic vNICs can only be bound to the service profile through an updating template.
- C Dynamic vNICs are bound directly to a service profile.
- D Dynamic vNICs are assigned by binding a port profile to the service profile
57After staging a VEM file on a VMware ESXi 5.0 host in the /tmp directory, what is the correct command syntax to install the VEM?
- A esxcli software vib install –d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
- Besxcli software vib install –v /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
- Cesxupdate software vib install –d /tmp/VEM500-20110825132140-BG-release.zip -maintenance-mode
- Desxupdate software vib install –v /tmp/VEM500-20110825132140-BG-release.vib -maintenance-mode
58Which network driver is required on a VMware ESXi 5.0 host for a vNIC to enter Cisco VM-FEX universal passthrough mode?
- A VMXNET3
- BVlance
- C Flexible
- D E1000e
- EVMXNET5
59Which virtual hardware version is required for a VM to enter the Cisco VM-FEX universal passthrough mode?
- A Version 5
- B Version 6
- C Version 7
- D Version 8
- E Version 9
60Which feature must be configured for Linux VMs to be able to transition from Cisco VM-FEX standard mode to universal passthrough mode?
- ARSS
- BMSI Interrupt Mode
- CVEMDPA Agent
- DExecute Disabled Bit
- EProcessor C State
61Which of the following is true concerning the Global Chassis Discovery policy configuration on the Cisco Unified Computing System Manager when using Cisco Unified Computing System 22XX I/O modules with Cisco UCS 62XX Fabric Interconnects?
- AThe link grouping preference should be set to discrete mode when the number of northbound links are not a power of 2.
- B Set the action policy-count higher than the actual number of uplinks; otherwise, the Cisco Unified Computing System servers will not be discovered.
- CFor Cisco Unified Computing System implementations that mix I/O modules with different numbers of links, it is best to manually reacknowledge the chassis in order to use all available links
- D Automatic reacknowledgement due to chassis discovery is never disruptive.
62Which of the following is the most accurate concerning the link configuration between Cisco Unified Computing System 22XX I/O modules and Cisco Unified Computing System 62XX Fabric Interconnects?
- A Port channels are always recommended when using source-dest-mac load balancing.
- BThe addition of links to a port channel requires a reacknowledgement.
- C You cannot mix and match discrete links and port channeling for different chassis when using 22xx
- DPort channels do not require a Global Chassis Discovery policy.
63Which of the following is not a feature of the Cisco Unified Computing System VIC-1280 adaptor?
- Acapable of up to 256 virtual interfaces
- Bsupports FCoE
- Csupports Cisco VM-FEX
- Dcompatible with the C- or B-Series Cisco Unified Computing System servers
64Which of the following is true with respect to recovery from failure with automatic pinning that is configured on a cluster of Cisco Unified Computing System 62XX Fabric Interconnects?
- ABy default, server MAC addresses are pinned to uplink interfaces using PIN groups.
- BWhen a northbound fabric interconnect link goes down, the affected servers will use NIC teaming to re-establish connectivity on the second fabric interconnect
- CWhen a northbound fabric interconnect link goes down, the fabric interconnect will send a gratuitous ARP to the northbound switch to announce the servers on the new port.
- DIn the event that all uplink ports on the fabric interconnect lose connectivity, the 22XX I/O module shuts down all of the host ports until at least one uplink is restored
65How does a Cisco Unified Computing System react when configured for disjoint Layer 2 domains?
- A Automatic pinning is disabled; VLAN membership must be statically pinned to the uplink ports.
- B. VLANs must be divided between the fabric interconnects using PIN groups.
- CThe VLAN traffic for a disjoint network can only travel along an uplink that is specifically assigned to this VLAN and is selectively excluded from all other uplinks.
- DWhen you configure disjoint Layer 2 networks, you must assign VLANs to uplink interfaces.
66Which of the following is true with respect to hardware failover or NIC teaming within a Cisco Unified Computing System?
- A Hardware failover is specified by the operating system.
- B An uplink failure when using automatic pinning requires that hardware failover for the server vNIC be disabled.
- CNIC teaming is controlled by the vNIC
- DThe hardware failover option that is available for Ethernet does not affect Fibre Channel traffic.
67Which of the following is true concerning Fibre Channel communications on a Cisco Unified Computing System?
- AEach VSAN requires a dedicated VLAN to carry FCoE traffic
- B FCoE VLANs are created like Ethernet VLANs on Cisco Unified Computing System Manager
- C FCoE VLANs may overlap with Ethernet VLANs.
- D Cisco Unified Computing System Manager supports a maximum of 128 active VSANs.
68Which of the following are true concerning authentication within a Cisco Unified Computing System?
- AAuthentication domains are used to leverage individual authentication systems.
- B You can create up to 64 authentication domains, each associated with a provider group and realm in Cisco Unified Computing System Manager
- CAt login, the user can select the authentication domain to be used.
- D Cisco Unified Computing System supports LDAP or RADIUS for remote authentication.
- E A locally authenticated user account is authenticated directly through the fabric interconnect.
69Which of the following scenarios accurately demonstrate how the Cisco Unified Computing System ensures that a firmware upgrade is minimally disruptive to the data center unified fabric?
- A If an I/O module is upgraded to a version that is incompatible with its fabric interconnect, the fabric interconnect can automatically reactivate the I/O module to a compatible version
- BIf components like server BIOS, HBA, and RAID controller firmware are unsuccessfully updated through direct firmware updates, the update process will fall back to a host firmware package that is associated with the service profile.
- CIf an update of the subordinate fabric interconnect leaves it in a nonusable state, the primary fabric interconnect will automatically be updated to ensure that one fabric interconnect is running the most recent firmware.
- DAfter Cisco Unified Computing System Manager upgrades the subordinate node, only then is the active management node automatically synchronized.
70How many links are there between a second-generation IOM (Cisco UCS 2204 or 2208) and a third-generation half-width blade (Cisco UCS B200 M3 or B22 M3) in a Cisco UCS system?
- A1
- B2
- C4
- D8
71Which policy would you change to form a port channel between a Cisco UCS 6248 and a Cisco UCS 2208?
- A link aggregation policy
- B chassis discovery policy
- C IOM connection policy
- D link discovery policy
72The Cisco UCS 6200 Series Fabric Interconnects offer a new feature that allows dynamic port allocation for all of the 10 Gigabit Ethernet interfaces. What are these ports called?
- A universal ports
- Bflex ports
- C unified ports
- Dconverged ports
73In which situation would you be required to change a Cisco UCS system from end-host mode to switching mode?
- ADesign requirements call for the use of fabric failover.
- BFabric interconnect is connecting to disjoint Layer 2 networks upstream
- C HSRP routers are directly connected to the fabric interconnect.
- D Upstream Cisco Nexus 5000 is configured for vPC.
Informações
- Descrição
- Quiz sobre Sem título, criado por vcoleman em 02-02-2015.
- Autor
- vcoleman
- Idioma
- English
- Visualizações
- 2
- Avaliação
- Ainda sem avaliações Avalie este quiz