- 1What are your priorities when choosing an instrumental technique? Why?we need to define what data we want to know first before we pick a technique
- 2How do the environmental constraints dictate the choice of instrumental analysis?portability of instrument
size of instrument
safety
small footprint (NMR large footprint)
ease analysis - in space available
is it mechanically robust
vibrations? temp? humidity?
ease of maintenance
chemical disposal
lack of consumables
want as small waste as possible - 3How does the sample dictate the choice of instrumental analysis?main question is what's the analyte can the instrument actually identify what it is
secondary question is how much is in it?
easier to detect higher levels than trace levels
adulterants -
sample preparation - do u need all the steps, can you afford all the steps - 4What might the “something else” be in the ranking question? How important? Why?ease of contamination
what other things are in the sample
ease of sampling
ease of analysis
needs fast turn around (quick maintenance between uses means fast turn around)
footprint
consumables
cost
compliance
sample prep
confounding results - 5Mini-summary: Physical RestrictionsIdentification is the primary concern
…followed by quantification
Desirable to have:
-Ease of sampling
- Low (chemical) footprint
Problems associated with:
-Sample matrix
-Location, location, location - 6Electromagnetic Spectrum

- 7Transitions

- 8Electromagnetic Radiation : Units

- 9Simple Harmonic Oscillator How do we think of molecular vibrations?

- 10Simple Harmonic Oscillator

- 11Effect of Force Constant

- 12Mini-Summary

- 13Sampling Techniques: Transmission

- 14Sampling Techniques: ATR

- 15Q 1: Give a flow diagram for analysis from sample in to data out. What needs to happen? what are the steps involved between taking the sample from a user and getting an identification

- 16How is IR best suited to the task of identification in this context? why did the loop pick IR?fast analysis time
ease of sampling - clamp and click
minimal prep of sample required
spectrum rich in info - each peak is a characteristic
high discriminatory power
databases of typical samples are known
routinely used by trusted labs
need for separation not high
can handle mixtures up to a point - 17What are the weaknesses of IR for identification of these samples?spectra dominated by main component, if theres very little drug it might not be able to identify it
mixtures not that easy below 10%
not quantitative (sort of) - rough indication
if spectrum is not in database, you have to do more work
some samples do not give a strong signal - 18Give a flow diagram for quantitation by UV-vis. Why do they use UV-vis and not something else?

- 19Overall Summary Challenges:Variable drug ID, odd location, unknown sample matrix
- 20Overall Summary Benefits of IRFast, low footprint, can ID by matching to database
- 21Overall Summary Drawbacks:Mixtures can be difficult, quantification
- 22Overall Summary Quantification:By UV but need to extract
Separation ideally
Sample history needed
Because of location, compromises needed – HPLC not available. - 23summary of q 1 priorities

- 24summary of q 1 prioritiesaccuracy and precision
ease of use
speed
robustness of result and instrument
reliability
cost to purchase
cost to run
environment impact - waste disposal