  1. 17 Sterilization methods1. Autoclave
    2. Radiation
    3. Dry Heat
    4. Boiling
    5. Flashing
    6. Gas
    7.Cold disinfectant
  2. 2Autoclaving: 3 modes of actionHeat, steam, pressure
  3. 3What is the purpose of heat in the autoclave?To denature microbial proteins
  4. 4What is the purpose of steam in the autoclave?Supplies the heat, promotes penetration of the heat
  5. 5What is the purpose of pressure in the autoclave?Adequately heats the steam
  6. 63 factors affecting autoclavingTemperature, Pressure, Exposure time
  7. 7Minimums for Autoclaving (Temp, PSI, time)275° F - 15 PSI - 10 min
    250° F - 15 PSI - 15 min
  8. 8Advantages/Disadvantages: AutoclaveAdv: Economical, consistent, safe
    DIsadv: Dulls sharp instruments, need pressurized equipment, scorches fabric if too dry, damage instruments if not dried properly
  9. 9Flashing: 1. Typically used for? 2. Temp - PSI - Time1. Individual instruments (may have been dropped during surgery)
    2. 275° F - 32 psi - 4 minutes
  10. 10How does boiling water sterilize?Denaturing microbial proteins
  11. 11Boiling Water: Time for partly sterilized Time for fully sterilizedPartly - 20 min
    Fully - 3+ hrs
  12. 12Boiling Water: Advantages, disadvantagesAdv: Good for field work
    Disadv: Rarely used, autoclave is better
  13. 13Dry heat: Mode of action UsesMode of action: oxidation denatures proteins
    Uses: Powders and non-aqueous solutions, animal care facilities
  14. 14Dry heat: Advantages, disadvantagesAdv: Will not dull cutting edges
    Disadv: Hot air oven needed
  15. 15Gas sterilization: What gas is used? Mode of action?Gas: Ethylene Oxide
    Mode of action: Destroys metabolic pathways in pathogens
  16. 16Gas sterilization: Advantages, disadvantagesAdv: Good for heat-sensitive materials, electrical & optical equipment, will not dull instruments
    Disadv: Expensive, flammable, dangerous, carcinogenic, OSHA regulations
  17. 17Radiation: Mode of action UsesMode of action: damages cell enzymes and DNA
    Uses: Commercial preparation of pharmaceuticals, biologic products & disposable plastics
  18. 18Cold "Sterilization": Mode of action Advantages, disadvantagesMode of action: destroys metabolic pathways in microorganisms
    Advantages: Will not dull instruments, good for field instruments, not inactivated by organic material
    Disadvantages: Must be at correct concentrations, rusts, cause tissue damage