- 1Types of heat transfer?Radiation
heat flows in electromagnetic waves from hot to cold
Convection
molecules of cool air absorb heat and expand, rise, and carry
away heat
Conduction
heat is transferred directly through contact - 2Commercial - Heating and cooling can happen from occupants, lighting, computers ++ (80 kw/h per person) TRUE OR FALSETRUE ;)
- 3Less construction mass of a building means?Faster cool down
and heating cycle
(Only ambient Air
gets heated in
Building ) - 4What can can further enhance the energy storage capacity of inner Structure?Phase Change Materials
- 5Comfort is based on:Heat Sources and Materials
Location of Cooling / Ventilation - 6When is thermal mass required inside of a building?Solar Heat Gain - Passive + Active Solar
- 7Internal and External Influences on Buildings?- Heating Load from Occupants
- Heating Load from Lighting Computers and Other Sources
- Lightweight – Solid Thermal Mass
- Ventilation Wind / Pressure
- Solar Heat Gain
- Shading
- Rain - 8HVAC stands for Heating, Ventilation and Air Conditioning TRUE OR FALSETRUE
c'mon >:C - 9HVAC PROVIDES:Provides thermal comfort and indoor air quality
- 10Room air distribution means:Air delivery and removal from spaces
- 11System specific to the building happens in?medium to large buildings
- 12HVAC distribution A plenum allows?Possible air return in Light fixtures allows for cooling of fixtures and removal of excess Heat.
- 13Plenum is?a space for Air Circulation in the floor or ceiling.
- 14Heat Recovery Ventilator (HRV) is?Temperature transfer to incoming air
- 15Energy Recovery Ventilator (ERV) is?Temperature transfer to incoming air
and Humidity transfer to incoming air - 16what affect the heating and cooling requirements of the building?The shape of a buildings floor plate
- 17Often, in large and deep floor plates cooling is the major concern TRUE OR FALSETRUE NIG.
Due to people and
equipment providing a
large heating load - 18The stairs will NOT be positively pressurized to prevent smoke from entering for fire safety TRUE OR FALSEFALSE, THEY WILL LOSER!
In an emergency, smoke will
be prevented from entering
the stairs - 19CONDO have less heating load then OFFICES?YES
- 20In condos, in order to have tenants or suite owners pay for their own HVAC what happens?Condos and apartments will
have a stand alone, separate
heating and cooling system for
every unit - 21In offices typically 100% drywall or exposed ceiling is not recommended. WHY?due to acoustic problems
that are associated with a highly reflective ceiling. - 22HVAC SYSTEM What is Variable Volume Temperature (VVT)?Gas Fired Packaged Roof Mounted Equipment.
- 23What happens in VVT?Units are gas fired with electric cooling.
Ductwork is distributed from the roof unit within the ceiling space to the
spaces to be heated or cooled. - 24VVT PROS?-Cost.
-Simple system to install and operate.
-Provide free cooling when outside air temperature permit through a built in
economizer - 25VVT CONS?-Poor temperature control over a number of individual spaces.
-Units are outside; Maintenance can be an issue in the winter time.
-Roof has a lot of equipment located on it, additional structural
requirements
-higher operating costs than the other two systems.
-Gas piping to be installed over the roof.
-Operating life expectancy is 12-16 years.
-Additional Supplementary heating will be required in individual office etc. - 26HVAC SYSTEM What is Closed Loop Water Source Heat Pump System?Number of small indoor mounted
units that are electric with a high operating efficiency and Heating or cooling can be provided any time of the year for each
individual space - 27What happens in Closed Loop Water Source Heat Pump SystemHeat pumps are all connected
on a low pressure water piping loop.
Each heat pump has its own
refrigeration circuit and either
rejects heat to the water loop
when in cooling mode or takes
heat from the water loop when
in the heating mode.
The cooling tower is the only
piece of equipment located outside. - 28PROS of Closed Loop Water Source Heat Pump System?-Very Flexible.
-Additional heat pumps can be added to the loop if use changes.
-Very good temperature control. Maintains set point in every space.
-Only one piece of outside equipment.
-No central cooling plant
-Maintenance is easier than option VVT
-Very energy efficient. - 29CONS of Closed Loop Water Source Heat Pump System?-Load sharing. Units in cooling assist units in heating. Balanced load
-More expensive system than option 1.
-Compressor is installed in each unit, slightly noisier than fan coils.
-More units to service (i.e. filter compressors etc).
-A more complex system to install than option VVT.
-Condensate lines have to be installed to each unit. - 30HVAC SYSTEM What is Fan Coil System A?Provided with a number of small indoor mounted units. Units are provided with water coils and a supply air fan.
The two pipe system uses a supply and return piping system to each fan coil.
This system cannot provide heating and
cooling all year round. - 31What happens in Fan Coil System B?This system can provide heating and
cooling year round if there is a four pipe system using two supply and return systems to each fan coil. One thermostat controls each unit - 32PROS of Fan Coil System B?-Flexible.
-Additional Fan coils can be added to the loop if the internal characteristics of the
building change.
-Reasonable temperature control.
-Only one piece of outside equipment.
-Maintenance is easier than option VVT and loop water
-Energy efficient - 33CONS of Fan Coil System B?-More expensive system than option VVT & Loop water
-More units to service (i.e. filters etc).
-Can not provide heating or cooling year round.
-A more complex system to install than option loop water & VVT
-Condensate lines have to be installed to each unit - 34HVAC SYSTEM FORCED AIR PROS?Ducting system can also be used for air conditioning
Many heat sources can be used although electricity required for fans
Forced air provides quickest response to temp change - 35HVAC SYSTEM FORCED AIR CONS?Ducting requires a lot of space and must be pre-planned in design of building
Potential loss of heat due to long duct runs
May create temp swings more noticeable then hot water
Not ideal for People with Allergies - 36HVAC SYSTEM Whats is LAKE WATER COOLING?3 intake pipes draw water from
5 kilometres off shore of Lake
Ontario at a depth of 83 metres
Cold water comes to the John Street
pumping station
Provides alternate air conditioning - 37HVAC SYSTEM How does GEOTHERMAL work?The geothermal system
consists of 280 wells located
under the building. Each well
is almost 121 m (396 ft.) deep
and contains a closed loop of
glycol. - 38Toronto Frost Level?1200mm
- 39HVAC SYSTEM WHAT IS SOLAR PV?Production of on site Electricity
and Storage or Grid Feed. - 40HVAC SYSTEM WHAT IS SOLAR HYDRONIC?Production of on site Hot Water where in the Evacuated Tube Hot Water Heat transfer at the top of the tubes can be direct hot
water supply or secondary loop post heat exchanger