GoConqr hat ein neues Design! Sag uns, wie es dir gefällt.

Karteikarten

Modalities

clingenhoel Englisch 14 Karten

Karten in diesem Stapel (14)

  1. 1Ultrasound: Thermal vs nonthermalThermal: continuous
    Non-thermal: duty cycle 20-50%
  2. 2Goals for thermal ultrasoundIncrease tissue extensibility
    increase tissue perfusion
  3. 3Goals for non-thermalIncrease tissue healing
    Increase protein synthesis
    reduce inflammation
    Reduce muscle spasm
  4. 4Deep vs Superficial3 Hz: Superficial
    1Hz: Deep layers
  5. 5PhonophoresisTo drive medications through skin into deeper tissues (lidocaine) or anti-inflammatory (dexamethasone)
    Mode: Pulsed 20%
    Intensity 1-3 w/cm2, 5-10 min
    Goal: dec pain and inflammation, subacute/chronic
  6. 6Lumbar distractionL5-S1: 45-60 deg hip flexion
    L3-L4: 75-90 deg hip flexion
    Goal: increase space between foramen & facets, and elongate mm
    Acute: 30-40lbs
    Disc protrusion: 25% BW (prone if displaced posterior)
    Joint distraction: 50 lbs/50% BW
    Time: 5-10 for disc, 10-30 other
  7. 7Precautions & Contraindications for tractionPrecautions: claustrophobia, impaired cognition, vascular compromise, RA/OA, tumor, pregnancy
    CONTRAINDICATION: Acute symptoms, spondy, fracture , hypermobility/instability, hypertension, neurological symptoms**
  8. 8Cervical tractionNever exceed 7% of BW or 20-30 lbs (joint distraction)
    10-15 lbs for disc herniation
    Supine is preferred
    20-30 deg of flexion
    Duty Cycle: 3:1 OR 1:1 for inc mobility
  9. 9IontophoresisApplication of continuous direct current using ES to disperse medication.
    Medication should be applied to "like" charge pad (anode -, cathode +)
    -Treatment time: 10-30 min
    Dose=anode: 1mA/cm, cathode: 0.5 mA/cm
    Anode should always be double size of cathode
  10. 10Contraindications of IontophoresisSame as ES +
    Skin integrity compromised
    Allergy to medication
  11. 11RussianPulse rate- 50-70
    Amp: visible muscle contraction
    Pulse Duration 50%
    Mode: interrupted. ramp 1-5 sec, duty cycle: 1:5
  12. 12Functional ES (NMES)Wave form: asymmetric biphasic
    Amp: visible muscle contraction
    Pulse rate: 12-25 ops (low)
    Pulse duration: 20-250 micro sec (low)
    *Can be switched on/off DF during gait, or used during treatment
  13. 13Contraindications for ESPacemaker, arrythmias, unstable angina, cancer, seizure disorder
    Area: carotid, eyes, thoracic region, phrenic nerve, low back during pregnancy, urinary bladder stimulators, malignancies, healing fractures
    Superficial metal implants, active infection/bleeding, pharyngeal muscles
  14. 14PrecautionsCardiac disease, dec sensation, dec cognition, menstrating uterus, pregnancy, hypotension/hypertension, inc adipose tissue

Informationen

Beschreibung
Karteikarten am Modalities, erstellt von clingenhoel am 08/02/2016.
Erstellt von
clingenhoel
Aufrufe
0
Bewertung

Feedback

Worum geht es?

Wie gefällt dir das neue Design?

Dein Eindruck