Quiz
Chapter 3 Cabling, Pathway & Spaces Part 1
Erstelle ein kostenloses Konto, um dieses Quiz zu beenden
Speichere deinen Fortschritt und sieh dir dein Endergebnis an.
oder mit deiner E-Mail registrieren
Schon ein Konto? Anmelden
Fragen in diesem Quiz (37)
1A Consolidation Point (CP) should serve up to 24 work areas?
- ARichtig
- BFalsch
2How many walls of a TR should have fire-retardant plywood?
- A2
- B1
- C3
- D4
3Cross-Connect Field Colors: Second-Level Backbone
- AGray
- BOrange
- CWhite
- DBrown
4This type of backbone cabling distributes telecommunications services between telecommunications spaces within a single building
- AIntrabuilding
- BInterbuilding
- CFiber Optic
5What is the maximum length of FMT
- A20 feet
- B10 feet
- C15 feet
- D25 feet
626 AWG has ______ more attenuation
- A50%
- B20%
- C30%
- D40%
7Cross-Connect Field Colors: Network Connections
- AGreen
- BBlue
- CPurple
- DYellow
8This type of backbone consists of cabling that is installed between a MC and IC/HC
- AFirst Level
- BSecond Level
- CInterbuilding
- DFiber Optic
9Cross-Connect Field Colors: First Level Backbone
- AWhite
- BGray
- CBrown
- DBlue
10It is acceptable to use a TE in place of a TR
- ARichtig
- BFalsch
11What is the minimum size of stub up conduits
- A3/4"
- B1/2"
- C1"
- D7/8"
12One of the primary functions of the ____________ is to house the floor-serving cross-connections and interconnection
- ATR
- BER
- CTE
- DEF
13If using a MUTOA, what is the maximum length of a 24AWG, stranded work area cable if the horizontal cable is 70 meters
- A22 meters
- B25 meters
- C5 meters
- D27 meters
14What is the maximum amount of moisture allowed in plywood backboards
- A15%
- B20%
- C5%
- D10%
15Select the 3 types of centralized fiber cabling implementations
- APull-through
- BInterconnection
- CSplice in the TR
- DHome Run
16Open top cable supports are typically intended to support how many cables
- A50
- B20
- C30
- D40
17Cross-Connect Field Colors: Miscellaneous
- AYellow
- BBlue
- CPurple
- DGreen
18What is the maximum length for horizontal fiber runs
- A90 meters
- B100 meters
- C2,000 meters
- D3,000 meters
19This administration addresses infrastructure with multiple buildings at a single site
- AClass 1
- BClass 2
- CClass 3
- DClass 4
20This administration addresses infrastructure with one or more telecommunication spaces in a single building
- AClass 1
- BClass 2
- CClass 3
- DClass 4
21Which is the required physical topology for SCS
- AStar
- BRing
- CBus
22Cross-Connect Field Colors: Horizontal Cable
- ABlue
- BGreen
- CYellow
- DOrange
23Plywood backboards should be mounted at _____ AFF
- A8 inches
- B12 inches
- C6 inches
- D18 inches
24What type of entrance pathway preserves the aesthetic appearance of the building and is economical over the life cycle
- AUnderground
- BBuried
- CAerial
- DWireless
25This administration addresses infrastructure with multiple sites or campuses
- AClass 1
- BClass 2
- CClass 3
- DClass 4
26What type of entrance pathway preserves the aesthetic appearance of the building but is inflexible for future service changes
- Atunnel
- Bunderground
- Cburied
- Daerial
27What diameter of toggle bolts should be used when mounting a backboard
- A1/4"
- B3/8"
- C1/2"
- D5/8"
28Open top cable supports should be installed to maintain a minimum of _____ inches above ceilings
- A2
- B3
- C4
- D5
29This administration addresses the needs of premises served by a single ER (the only telecommunication space)
- AClass 1
- BClass 2
- CClass 3
- DClass 4
3024AWG stranded cable ha _______ more attenuation
- A30%
- B20%
- C50%
- D40%
31How far should the toggle bolts be spaced when mounting a backboard
- A1ft
- B2ft
- C18 inches
- D3ft
32The inside bend radius shall be _______ times the ID for conduits 2 inches or less
- A6
- B10
- C4
- D8
33Cross-Connect Field Colors: Common Equipment
- APurple
- BGreen
- CYellow
- DRed
34The inside bend radius shall be ___ times the ID for conduits greater than 2 inches
- A10
- B6
- C4
- D8
35Which entrance pathway has the lowest cabling installation cost
- AAerial
- BUnderground
- CBuried
- DWireless
36This backbone cable distributes telecommunications services between buildings
- Ainterbuilding
- Bintrabuilding
37Cross-Connect Field Colors: Demarcation Point
- AOrange
- BBrown
- CWhite
- DRed
Informationen
- Beschreibung
- Technician
- Autor
- eric rinehart
- Sprache
- English
- Aufrufe
- 134
- Schlagwörter
- Bewertung
- Noch keine Bewertungen Bewerte dieses Quiz
Mehr zu Structured Cabling and Installation