Frage 1
Frage
The total heat content of infiltrated air of the same dry-bulb temperature may vary from one part of the country to another because of the difference in __________.
Antworten
-
Solar load
-
Sensible heat
-
Humidity
-
Convection currents
Frage 2
Frage
A homeowner plans to build a house out in Las Vegas, Nevada, in the middle of the desert. It would be in his/her best interest to lower the "solar load," to locate most of the windows on the __________.
Antworten
-
west side of the house
-
east side of the house
-
north side of the house
-
south side of the house
Frage 3
Frage
The solar load on a structure is the heat gain resulting from the __________.
Antworten
-
heat from the surrounding air conducted through the materials of the structure
-
air infiltration
-
heat from the radiation from the sun
-
dry-bulb inside the structure
Frage 4
Frage
More than one evaporator coil circuit is used when __________.
Antworten
-
a slant coil is at an angle more than 60°
-
the evaporator is located outside the conditioned area
-
there would be excessive refrigerant pressure drop in the coil circuit
-
a distributor would not be practical
Frage 5
Frage
A popular material combination used in air conditioning evaporators and condensers is __________.
Frage 6
Frage
In reciprocating and scroll type motor-compressor assemblies, the motor is cooled by __________.
Antworten
-
liquid refrigerant by-passed from the liquid line
-
discharge gas from the compressor
-
suction gas returning to the compressor
-
air over the shell of the assembly
Frage 7
Frage
In rotary type motor-compressor assemblies, the motor is cooled by ____.
Antworten
-
discharge gas from the compressor
-
liquid refrigerant by-passed from the liquid line
-
air over the shell of the assembly
-
suction gas returning to the compressor
Frage 8
Frage
A dirty condenser coil can lead to ____.
Antworten
-
increased efficiency
-
reduced efficiency
-
increased heat transfer
-
increased subcooling
Frage 9
Frage
High efficiency condensers ____.
Antworten
-
are located in separate cabinets
-
have stainless steel coils
-
have more surface area than standard condensers
-
can withstand higher pressures than standard condensers
Frage 10
Frage
The package air-conditioning system is _____ than the split system because it is completely factory assembled and charged with refrigerant.
Antworten
-
less efficient
-
slightly less efficient
-
slightly quieter
-
more efficient
Frage 11
Frage
On a package air conditioning system, which refrigerant lines must be field installed?
Frage 12
Frage
On a split air conditioning system with a remote condensing unit, which refrigerant lines must be field installed?
Frage 13
Frage
The air temperature of the air off an evaporative cooler is ____.
Antworten
-
cooler than the entering air
-
made up of sensible heat only
-
a constant 32 degrees
-
the same as the entering air
Frage 14
Frage
The humidity difference in the 2 different locations (different parts of the country) must be accounted for in the conditioning equipment choice.
Frage 15
Frage
The all-aluminum coil has a higher heat transfer rate than the standard copper tube-aluminum fin coil.
Frage 16
Frage
Leaks in all-aluminum coils are easier to repair than the standard copper tube-aluminum fin coil.
Frage 17
Frage
Equipment will perform at it’s best efficiency when running at full load.
Frage 18
Frage
If a residential split air conditioning system has a compressor equipped with a start capacitor and relay, it is probably using a thermostatic expansion valve as a metering device.
Frage 19
Frage
The supply duct portion of an air handling system needs to be insulated when run through an unconditioned space.
Frage 20
Frage
The return duct portion of an air handling system never needs to be insulated.