Apuntes
The Dive Response (04/11/13 prac)
Contenido del apunte (1)
Página 1
The Dive Response
(04/11/13 prac)
The dive response enables aquatic mammals to conserve oxygen by
decreasing heart rate and blood flow to the extremities. In terrestrial animals,
oxygen consumption actually rises as a result of submersion in cold water in
order to prevent core temperature from dropping, so the bradycardia (resting HR
conserve heat.
In this lab, we
triggered the dive response by suddenly submerging the subject’s face in cold
water (~10°C), stimulating the trigeminal nerve receptors around the nose.
As water temperature decreases, stimulation of the receptors is
enhanced, and the severity of the bradycardia increases. Enhanced stimulation
of these receptors results in an inhibition of the cardiovascular centre, as
well as subsequent reduction in heart rate through both enhanced
parasympathetic output and reduced sympathetic output to the heart.
We compared the
circulatory effects of the dive response with breath-holding, and found that
while the dive response initiates bradycardia and there are minimal O2/CO2
effects, breath-holding initiates tachycardia, hypoxia and hypercapnia.
For these first two experiments, we attached a finger pulse
transducer to the middle finger of the volunteer and to the PowerLab panel. For
both experiments, the volunteer held their face over the water to establish a resting
heart beat for 15 seconds, then for the dive response they submerged their head
under water for 30 seconds (another person tapped their back every 10 seconds
to keep time) and for the next experiment the volunteer held their breath above
the water for 30 seconds. For both experiments, a further 30 seconds of ‘recovery’
was recorded after breathing resumed.
In peripheral occlusion of the dive response, venous return to the heart
is disrupted, but the amount returned is also reduced along with cardiac output.
We replicated that by blocking venous return and then measuring the decrease in
the volume of the calf when the cuff was removed (as the gradual increase could
not be detected by the transducer, but the sudden decrease could).
For a third experiment, we attached a
blood pressure cuff and sphygmomanometer to the volunteer’s right thigh, and a
respiratory belt (attached to the PowerLab panel) around the right calf. After
a 10 second resting control, we repeated the above tests: resting with face
above the water, holding breath with the face above the water, and submerging
the face into the water. For the 30 seconds that the variables were being
performed, the cuff was inflated to 100mmHg. The cuff was ripped off to allow
for the most sudden volume change to be recorded by the transducer. After this
there was a 10 second resting recovery period. We recorded the change in volume
at this point for all three sets of conditions.
Class data:
Not available.
My data:
During the dive response, my heart rate stated the same initially but
the pulse amplitude increased (from 0.000585 to 0.00115, suggesting an
increased stroke volume). At the end of the dive, my heart rate had risen (from
56.66 BPM to 72.53 BPM) and the pulse amplitude had lowered slightly (from
0.00115 to 0.000875, showing a higher rate and slightly lower stroke volume).
30 seconds after the dive, my heart rate began to return to resting (from 72.53
BPM to 65.36 BPM) but the pulse amplitude continued to increase (from 0.000875
to 0.001375) suggesting that stroke volume was still increased to compensate
for the hypoxia.
Tachycardia occurred
instead of bradycardia – I expect that this was because the water was too warm
at 10°C, but also because I panicked slightly as I felt water travelling up my
nose.
As expected, during breath holding my heart rate rose similarly and the pulse
amplitude decreased in shorter, shallower beats (Rest: 67.44 BPM, 0.00062; 15s
in: 83.68 BPM, 0.00052; End: 89.56 BPM, 0.00046; Recovery: 70.77 BPM, 0.0005).
Lastly, with the leg blood volume, the change in volume was decreased in the
dive response (at rest, the change was 0.18V, whereas it was 0.09V in the dive
response), but increased during breath-holding (to 0.33V).
The lower change in the
dive response is expected, as stroke volume is decreased so there is less blood
to return to the heart, meaning that less will accumulate when return is
occluded. In the breath-hold, there is increased cardiac output to address the
tissue hypoxia, so there will be more blood to return to the heart, resulting
in a larger accumulation when return is occluded.
The dive
response is more of a survival mechanism than a pathological presentation.
However, the circulatory effects of breath holding were clear, and could be
similar in pathologies in which air flow and gaseous exchange is restricted,
such as emphysema, pulmonary fibrosis, and asthma. Clinically, the dive response can be used to restore sinus rhythm
to those with paroxysmal supraventricular tachycardia. This can occur with
digitalis toxicity, or in Wolff-Parkinson-White syndrome in which a person has
an extra pathway for impulses to travel in the heart.
New Page
Información
- Descripción
- The physiological basis, methodology, results, and clinical relevance of the Dive Response, from the 04/11/13 Human Physiology lab.
- Creado por
- sophietevans
- Visitas
- 665
- Etiquetas
- Valoración