Test
Mass spectrometry techniques: MALDI, ESI and EPR
Crea una cuenta gratis para terminar este test
Guarda tu progreso y consulta tu resultado final.
¿Ya tienes cuenta? Inicia sesión
Preguntas del test (15)
1What is an isotopomer?
- ATwo molecules that differ by arrangement of isomers
- BSame chemical formula but different isotopes
2Which of the following is false about Electron Impact ionisation?
- ASample must have a low vapour pressure as it is vaporized into the mass spectrometer
- BA beam of electrons then impacts the sample to ionise it
- CIt is commonly used with CO ligand complexes
- DIt is limited to charged molecules
3Which of the following is an explanation for how MALDI works?
- ASample molecules are co-crystallised in a matrix such as dithranol
- BSample is vaporized and then impacted by a beam of electrons
- CIt is a hard ionisation method
4For the MALDI technique the matrix has a small molar absorption coefficient
- AVerdadero
- BFalso
5MALDI technique involves proton transfer to the analyte
- AVerdadero
- BFalso
6MALDI requires internal charges to start with
- AVerdadero
- BFalso
7MALDI is a soft technique that leads to little fragmentation
- AVerdadero
- BFalso
8Which of the following best describes the method of electrospray?
- ASpray of charged droplets produced which passes through flow of drying gas to evaporate solvent
- BSample co crystallised in a matrix
- CThe sample is vaporised
9In ES no fragmentation occurs and a sequence of peaks can be seen, if there is a gap of 2 the it must be a +2 species
- AVerdadero
- BFalso
10What is cone voltage?
- AAccelerates ions relative to neutral gas molecules
- BThe voltage at which the ms is conducted at
- Cresults in non energetic collisions
11Which of the following are bad points of the ES technique?
- AVery sensitive to contaminants hence poor reproducability
- BSpectrum can be confusing with so many peaks at one point
- CMass range of up to 100kDa
- DGood for polar, basic compounds which can easily be charged
12Which of the following have the shortest timescale?
- ANMR
- BIR
- CEPR
13The principle used in the EPR technique is that compounds with one unpaired electrons have two states: +0.5, -0.5
- AVerdadero
- BFalso
14The zeeman effect results in the equation:
- AE=g*mu*B
- BE=g*y*h
15Hyperfine coupling is the interaction between the electron and the nuclei
- AVerdadero
- BFalso
Información
- Descripción
- Test sobre Sin título, creado por nicola.bowen el 19/11/2015.
- Autor
- nicola.bowen
- Idioma
- English
- Visitas
- 2
- Valoración
- Aún sin valoraciones Valora este test