Mass spec
Fichas del conjunto (42)
- 1Mass spect provides info onelemental composition
structural info
isotopic ratios
surface composition and structure - 2what is the analysis sequence for MS1. vaporization
2. conversion of molecules or atoms to ions
3. separation of ions
4. counting the number of ion - 3requirements for an inlets system in MSneeds to be able to vacuum, or pump sample into system
- 4the ideal ion in MS isa single positive charge
- 5what is the common ion source for atomic MSICP
- 6the resolution of MS depends onthe average mass and difference in mass of the ions
R=m(avg)/(delta)m - 7why does a good mass analyzer need a higher throughputhigh throughout= more ions=more currents, but this also contributes heavily to signal to noise ratio
- 8mass analyzers have the same function asas an optical monochromator
- 9what are the four general types of mass analyzers1. magnetic sector
2. quadrupole
3. fourier transform
4. time-of-flight - 10describe what happens in a magnetic sectora magnectic feild (B) is imposed on a curved path(w radius r). Ions are injected through an inlet with a kinetic energy based on their mass, and the potential of the inlet. only ions of a certain weight have the correct KE to travel the path. Other ions will hit the walls of the path.
- 11how do you change what ions pass through a magnetic sectoryou can change which ions pass by changing magnetic field, B, or potential at the inlet, V
- 12what is happening in a quadrupole mass analyzerions move between four charged rods, neg rods pull ions towards path, pos. poles pull ion away from path. An AC current is generated through the poles, which causes the ion to have a wiggle path.
- 13how does mass affect the path of ions in a quadrupoleas the current changes, the lighter ions are easier to pull away from their path, and heavier ions are harder to pull away from their path.
- 14how does the voltage effect what ions make it through a quadrupole mass spectat low volts, light ions will make pass, as the voltage increases, more heavy ions can make it through the path
- 15how does a quadrupole mass filter work?the xz plane acts as a high pass filter, and heavier masses can pass
the yz plane acts as a low pass filter, and allows for lighters masses to pass. Both of these together act as a notch filter, that changes width by voltage - 16describe what happening in ion trap and cyclotron resonanceions are generated and pulled into the box by a potential. In the box, a magnectic feild is imposed along the ion path, which causes the ions to circle around the center axis of the box. An AC current (RF pulse) is imposed on receiver plates, which cause ions to change, widen, their orbit. When the pulse is not present, the ions return tp their original path, and the time that takes depends on the mass of the ion. The return rate is measured by the receiver plate, which generates a currents as the ions contact it.
- 17how does the mass of the ion affect the angular velocity of the ions path in ion trapw (angular velocity)=v/r=ZeB/m
heavier ions have a lower angular velcoity, and vice verca. - 18Describe the components of the toroidal MS, and how it worksElectrostatic trap with an inner electrode
that is wide in the middle and narrow at the ends. Constant potential applied between the electrodes. Electric field varies with the distance between the outer and inner electrode. Ions move in a helix motion between the eletrodes. - 19Resonant circular motion of ions generates an_______ _________ orthogonal to the magnetic field.image current
- 20Fourier transform of the time domain decay signal yields a frequency domain signal that is inversely related to themass-to-charge ratio
- 21Advantages of toroidal MS-High resolution (>200,000)
‒ Large dynamic range and accuracy
‒ Compact and less expensive - 22disadvantages of toroidal MS‒ Number of ions in the chamber is limited to decrease the changes of collisions
‒ Requires lowest pressure requirements, extreme vacuum - 23how does ToF or ion mobility MS workions are injected with a specific, same, KE into a drift tube (there is no potenital that attracts the ions). The ions are separated by their masses by their change in KE as they move thru the tube. Ions are converted to current as they hit the detector.
- 24why does ToF have a high resolutionlong path length
- 25what does a reflectron dueUse of an ion mirror, or reflectron, to reflect ions can compensate for differences in kinetic energy because more energetic ions penetrate deeper into the reflectron and take a slightly longer path than less energetic ions. it increases resolution
- 26the molecular peak is theright most peak, most important
- 27the base peak isthe highest peak
- 28hard sourcesProduce fragment (daughter) ions (m/z < molecular ion)
‒ Structural or functional group
information
‒ Complex spectrum - 29soft sources- Little to no fragmentation
‒ Molecular weight is principal information
‒ Simple spectrum - 30a distinguishable difference between spectra from hard and soft sources ishard sources have many more peaks due to fragmentation.
- 31types of hard sourceselectron impact
- 32types of soft sourceselectrospray ionization ESI
MALDI
chemical ionization CI
feild ionization and desorption - 33Describe electron impact ionization sourceElectrons boiled off a heated tungsten filament and accelerated through a potential,70 V, electrons hit molecule and produce a radical
-Low mass and high KE causes small change in translational energy and leaves molecular ion in highly excited vibrational and rotational states, Relaxation leads to
fragmentation - 34advantage of electron impact ionizationConvenient to use
‒ Produces large ion currents (high sensitivity)
‒ Large fragmentation allows structural identification
o 70 eV spectra are library searchable
o “industry standard” - 35disadvantages of electron impactNo molecular ion peak
‒ Sample must be volatilized, Thermally stable sample
‒ Spectra often complex
‒ Inefficient process, 1:10^6 molecules
ionized - 36describe chemical ionizationa reagent gas is used in a 1000:1 ratio w sample. Electron beam ionizes reagent gas, reagent gas ion collide with the sample to ionize it/ Side reaction often occur.
- Proton transfer produces (M+1)+ peak.
‒ Hydride transfer produces (M-1)+ peak.
‒ Other species may transfer (OH-, C2H5+, …) - 37describe feild ionization and desorptionused for liquid or solids. Field ionization mass spectrometry depends on the tunneling of an electron from a molecule in the gas phase on passage through a steep electric field, to an electrode. Upper mass limit of 1200 m/z
- 38describe electrospray ionizationeluent is vaporized and ionized as it passes through a steel capillary with a high votage potential. The mobile is pumped away by a skimmer. must be cleaned often
- 39describe secondary ion mass spect (SIMS)a primary beam of ions are sprayed at a solid sample surface, secondary ions are generated by the spray of ions.
- 40describe matric assisted laser desorption and ionization (MALDI)ideal for biopolymers that fragment easily. Sample is irratiated with high energy UV pulse, and ions are generated.
- 41what are the three principles for the mechnism of maldi- To begin with, a matrix analyte solution must be prepared, and a cocrystal must be
formed.
‒ This cocrystal is then excited using a laser to produce a plume of cocrystal particles that subsequently interact to form molecular ions.
‒ The molecular ions are analyzed using a mass spectrometer. - 42—