Ayúdanos a dar forma a GoConqr. ¿Qué deberíamos añadir?

Fichas

International Building Code Part 2

Steven Hall South Carolina Commercial General Contractors Inglés 99 fichas

Fichas del conjunto (99)

  1. 1Structural plain concrete (un-reinforced) is permissible with each of the following except:Columns
  2. 2What is the minimum thickness of plain concrete exterior basement walls?7.5"
  3. 3What is the minimum thickness of plain concrete interior basement walls?5.5"
  4. 4Openings in concrete walls shall have not less than how many bars, and what size bars around the opening?1 bar on each side that is #5 bar extending 24" beyond the corners
  5. 5Vapor retarder for a slab on a grade shall be a minimum thickness of:6 mil
  6. 6What are the minimum requirements for a slab on grade?3 1/2" thick with a 6 mil vapor retarder with lap joints no less than 6"
  7. 7What is the minimum thickness for concrete slabs-on-grade?3.5"
  8. 8When placing shotcrete, the maximum size aggregate to be used is:3/4" aggregate
  9. 9When placing shotcrete, the maximum size of reinforcement shall be:No. 5 bars
  10. 10When placing shotcrete and bars smaller than No. 5 are used, the minimum clearance between parallel bars shall be how many inches?2.5" of clearance between parallel bars
  11. 11Lap splices of reinforcing bars used in shotcrete shall have aminimum clearance of:2"
  12. 12What is the closest reinforcement in pipe columns can be placed to the exterior steel shell?1"
  13. 13The minimum diameter of pipe columns in buildings not exceeding 3 stories or forty feet is:4"
  14. 14The minimum diameter of pipe columns in basements where the column is a secondary steel member, the minimum diameter shall be:3"
  15. 15Unused mortar shall be used within:2.5 hours
  16. 16What is the average compressive strength of type "N" mortar at 28 days?750 psi
  17. 17Most structural steel is ASTM:A-36
  18. 18The mortar bed on top of the footing should be between:1/4" - 3/4"
  19. 19What is the minimum bed joint when placed directly on the foundation?1/4"
  20. 20Head and bed joints for glass block shall be:1/4"
  21. 21The minimum length of end support of lintels shall be:4"
  22. 22What is the maximum on-center spacing for weepholes?33" on-center
  23. 23The minimum diameter of masonry weep holes shall be:3/16"
  24. 24Masonry columns used to support light-frame roofs over carports shall have a maximum column height of:12'
  25. 25What is the minimum thickness of a masonry weight bearing wall?6"
  26. 26What is the minimum thickness for a 3' high masonry foundation wall that supports one story of a structure with walls of light frame construction?6"
  27. 27The maximum height of an unreinforced 8" thick masonry parapet wall is how many inches?24"
  28. 28What would be the maximum support of a single brick tie for a multiple wythe wall?4.5 sq feet
  29. 29Roof diaphragms shall be anchored to a masonry wall with:1/2" diameter bolts embedded 15" into the masonry
  30. 30Bolts that are used for anchoring roof diaphragms are spaced:72" O.C.
  31. 31What is the minimum thickness for standard non load bearing glass block?3 7/8" Thick
  32. 32How many square feet of glass block are allowed in an exterior panel?250 square feet
  33. 33When a fireplace has a firebox opening of 5.7 square feet, the hearth shall extend a minimum of:16"
  34. 34When a fireplace has a firebox opening of more than 6 square feet, the hearth shall extend a minimum of:20"
  35. 35A masonry fireplace located in the interior of a building shall have a minimum clearance of:2" on the sides and 4" from the back
  36. 36What is the minimum height that a chimney shall extend above the point where it passes through the roof if the roof slope is 6/12?3'
  37. 37Masonry chimney walls shall not be less than how thick?4" thick
  38. 38Cold formed steel shall be protected against corrosion with:An approved coat of paint, enamel or other approved coating
  39. 39What is the minimum thickness of particle board underlayment?1/4" thick
  40. 40What is the maximum moisture content of lumber?19% moisture content
  41. 41What is the minimum board or sheathing thickness applied perpendicular to supports when rafter spacing is 24” o.c.?23/32" thick
  42. 42What is the required thickness of surface dry roof sheathing continuous over two or more spans with a 24" span?5/8" thickness
  43. 43What is the allowable maximum load for 5/8" wood roof sheathing, spanning 24" over two or more spans and strength axix parallel to supports?80 psf
  44. 44What is the minimum distance allowed for untreated wood floor joist to exposed earth?18"
  45. 45What is the minimum distance allowed for untreated girders to the grade below?12"
  46. 46What is the minimum distance for untreated framing to the grade below?8"
  47. 47What is the proper clearance around a girder entering a masonry or concrete pocket?1/2" of clearance
  48. 48What is the fastening schedule for a joist toe-nailed to a sill or girder?3 Nails of Size 8d common or Type 10d common
  49. 49What is the number and size of nails required to toe-nail a stud to a sole plate?4 Nails of Size 8d
  50. 50When a jack rafter is face nailed to a hip, how many 16d common nails are used?2
  51. 51The proper spacing of nails along the edge of plywood roof sheathing is:6" Spacing
  52. 52What is the minimum distance between untreated wood siding to exposed earth?6"
  53. 53Untreated wood is permitted where such wood is continously and entirely:Below the ground-water level or submerged in fresh water
  54. 541/2" gypsum sheathing has a maximum wall stud spacing of:24"
  55. 55Ends of header joists need hangers when they exceed what length?6 feet
  56. 56Braced wall line sills shall be anchored to the concrete or masonry foundations:4' on center
  57. 57Continous foundations are required at exterior walls only when maximum plan dimensions exceed:50'
  58. 58Foundation plates or sills resting on concrete or masonry foundations shall be bolted or anchored to the foundation with not less than:1/2" bolts embedded at least 7" and no more than 6 feet on center
  59. 59Anchor bolts embedded in a concrete slab for securing a bottom plate are spaced no further than how many feet?6'
  60. 60The Building Code allows you to cut what size notch at the end of a 2 x 10?2.5"
  61. 61What portion of a joist is not allowed to have a notch cut into it?The middle third
  62. 62What is the maximum size notch that can be cut into the top or bottom of a joist that is not near the edge?1/6 of the joist depth
  63. 63What is the minimum overlap for double top plates?48"
  64. 64What is the maximum stud spacing for non-bearing interior walls and partitions?28"
  65. 65What is the maximum spacing for 2 x 4 wall studs supporting roofs and ceilings only?24"
  66. 66What is the maximum stud spacing when installing gypsum board over the studs?24"
  67. 67A load-bearing stud may be notched to a depth not to exceed what percentage of its width?25%
  68. 68In a 2 x 4 load-bearing wall, what is the maximum size hole that can be bored through the stud?40%
  69. 69In a 2 x 4 non load-bearing wall, what is the maximum size hole that can be bored through the stud?60%
  70. 70Rafter ties are spaced how far apart?Not more than 4'
  71. 71How close can a hole be bored from the edge of a floor joist?2" from the edge
  72. 72What is the maximum diameter of a hole in a joist?1/3 of the joist depth
  73. 73Cement plaster over exterior wall studs requires galvanized weep screed with a:3 1/2" vertical leg at least 4" above the earth
  74. 74Smoke control systems shall have:Stand-by power
  75. 75Construction equipment and materials shall be stored and placed:So as not to endanger the public, workers or adjoining property
  76. 76Stumps and roots shall be removed from the soil to a depth of:12"
  77. 77The maximum slope for permanent fill is:50%
  78. 78Roof covering over walkways or sidewalks at construction sites must have how many feet clearance above the walkway?8' OF CLEARANCE
  79. 79A covered walkway is required to protect pedestrians during construction of a 60' building with what minimum distance from the street?5' from the street
  80. 80What is the minimum required width of walkways around a construction project?4' wide walkways
  81. 81If a fence is required at a jobsite, the minimum height would be:8' High
  82. 82Prior notification to neighbors of any work to begin shall be made:10 days prior to starting work
  83. 83What is the minimum space for fixed seating?18 inches
  84. 84A flight of stairs shall not have a vertical rise greater than ___ between fllor levels or landings.12 foot
  85. 85Stairs should always have a minimum of ____ headroom clearance?80 inches
  86. 86Fasteners for asphalt shingles shall penetrate the roofing materials a minimum of:.75 inch
  87. 87A cricket or saddle shall be installed on the ridge side of any chimney greater than how many inches wide?30 inches
  88. 88For asphalt roof slopes from 2/12 up to 4/12 underlayment shall be 2 layers. Apply a minimum___ inch wide strip of underlayment felt parallel with and starting at the eaves.19 inches
  89. 89Wood shake shall be laid with a side lap not less than how many inches?1.5"
  90. 90What is the exposure for No. 1 grade taper sawn shakes 24 inches long of naturally durable wood with a 4/12 pitch roof?8" of exposure
  91. 91When the ground water table is lowered and maintained at an elevation of not less than ___inches below the bottom of the lowest floor, the floors and walls shall be dampproofed.6"
  92. 92What is the minimum slope required for a building foundation with impervious surfaces present within 10 feet?2% slope
  93. 93Waterproofing floors shall be accomplished by placing a membrane of rubberized asphalt, or butyl rubber, or not less than ____ mil polyvinyl chloride with joints lapped not less than ___inches.6 mils polyvinyl chloride and 6 inch of joint lap
  94. 94What is the maximum amount of fly ash that can be added to concrete exposed to deicing chemicals?25%
  95. 95What is the maximum vertical and horizontal spacing of masonry wall ties?24" vertical and 36" horizontal
  96. 96Spacing between adjustable masonry wall ties should not exceed ___ inches vertically.16"
  97. 97When temperatures are very hot (100 degrees or 90 degrees with a wind velocity greater than 8 mph) brick mortar shall be discarded after ____ hours.1 hours
  98. 98What is the minimum thickness of structural sheathing on a 24 inch span that may be used on roofs?7/16" thickness
  99. 99What is the minimum nail length for fastening mechanical floor laminates?Not less than two and one-half times the net thickness of each lamination

Información

Descripción
South Carolina Commercial General Contractors Fichas sobre International Building Code Part 2, creado por Steven Hall el 23/12/2017.
Creado por
Steven Hall
Visitas
0
Valoración

Más sobre Structural Construction Requirements

Escríbenos

¿Sobre qué es tu mensaje?

¿Qué deberíamos añadir?