- 11704.2 the people who employ one or more approved agencies to perform inspections are the ___ or the ____ _____.owner,the owner's agent
- 21704.2 special inspections are not required for construction of a ______ ______ as approved by the ________ ______.minor nature, Building Official
- 31704.2.1 the Special Inspector shall provide written documentation to the______ _______ demonstrating his competency and relevant experience or training.Building Official
- 41704.2.4 the Special Inspector shall furnish inspection report to the ______ ______ and to the in_____ ____ ________ responsible charge.Building Official ,registered design professional
- 51704.2.4 discrepancies should be brought to the attention of the _____ ____ and to the _______ ______ _____ in responsible charge prior to the completion of that phase of the work.Building Official ,registered design professional
- 61704.2.5.1 special inspection shall not be required where the fabricator is _____.Approved
- 7the statement of special inspections for seismic design category d,e, f can be found in IBC _____.1704.3.1
- 81905.1.7 horizontal reinforcement shall be provided _____ at structurally connected roof and floor levels and at the top of walls.continuously
- 91905.1.8 in detached one and two family dwellings assigned to seismic design category D or E, the height of the wall shall not exceed __ feet ,the thickness shall not be less than ___ inches, and the wall shall retain no more than___ feet of unbalanced fill.8 feet, 7 1/2 inches, 4 feet
- 101905.1.8 bars in plain concrete footings shall not be smaller than number __.4
- 111905.1.8 for plain concrete footings that exceed ___ inches in thickness, a minimum of __ bar shall be provided at the top and bottom of the footing.8 inches, one
- 121905.1.8 for foundation systems consisting of a plain concrete footing and a plain concrete stemwall,a minimum of ___ bar shall be provided at the top of the stem wall and at the bottom of the footing.One
- 131905.1.8 where a slab on ground is cast ___ with the footing, one No. ___ bar is permitted to be located at either the top of the slab or bottom of the footing.Monolithically, 5