- 1Palace of king Minus Location?Knossos, Crete
- 2A Palace that has groups around a central courtyard that are surrounded by cypree wood columns that tapered downward?Palace of King Minus
- 3What kind of Matrials that use as a column in Palace of king Minus?Cypress Wood
- 4Other called in Cypress Wood Column?Minoan Column
- 5A Council House?BOULEUTERION
- 6Give one (1) example of Bouleuterion council house?Council Hall of Miletus
- 7Other name for Treasury of Atreus?TOMB OF AGAMEMNON
- 8Other name for Tomb of Agamemnon?TREASURY OF ATREUS
- 9Parts of Tomb of Agamemnon which has long passageway?DROMOS
- 10Parts of Tomb of Agamemnon characterized in beehive shaped and long chamber?THOLOS
- 11Under 3.1, Sidewalk, What are the two consideration regarding slope and Materails to be use?* Sidewalk should kelp level as possible
* Provide Slip-Resistance Materials - 12Whenever and wherever possible, Sidewalk should have a gradient no more than what slope and percentage?1:20 or 5%
- 13Sidewalk should have a maximum cross gradient of?1:100
- 14Sidewalk should have a minimum width of ?1.20 Meter
- 15If possible grating should never be located along sidewalk; when occurring along sidewalk, Grating opening should have a maximum dimension of what size?13mm X 13MM
- 16If possible grating should never be located along sidewalk; when occurring along sidewalk, It shall not project more than how much in size above or or below the level of the Sidewalk?6.5mm
- 17Sidewalk should have a continuing surface without abrupt pitches in angle or interruption by cracks or breaks creating edges above. How much is the maximum pitches allowed in height?6.5mm
- 18In Lengthy or busy sidewalk, spaces should be provided at some point along the route so that a wheelchair may turn around these spaces should have a minimum dimension of?1.50 Meters
- 19In Lengthy or busy sidewalk, spaces should be provided at some point along the route so that a wheelchair may pass another and should be spaced at a maximum distance of how much lenth between the stops?12 Meters
- 20To guide the blind, Sidewalk shoud as much as possible______________?* Follow straight forward route
* And with right angle turns - 21Where planting is provided adjacent to the walkway, branches of trees or shrubs should have_________________ for these wil not overhang toward sidewalrd or paths, as they do not only present a particular danger to the blind, but they also reduce the effective footway width available to pedestrian.Regular Maintenance
- 22Minimum Height if Sidewalk Headroom?2.00 Meter
- 23Passageway should not obstructed along the defined route, as they can be hazardous, what are these things?* Street furniture
* Bollards
* Sign Post
* Colums - 24Handrail shall be installed above steps or ramps, What is the Standard Height of Handrail?0.70m & 0.90m
- 25Handrail for protection shall be installed at great height?1.00m to 1.06m
- 26How long the extension of handrail should be provided at the start and end of ramps and stairs?0.30 meter
- 27Handrail that require full grip should have a dimension of of?30mm to 50mm
- 28Handrail Attached to Wall should have a minimum clearance from the wall?50mm
- 29Handrail on Ledges Should have a minimum clearance of?40mm
- 30Where open spaces are provided, The blind can become particularly disoriented. Therefore, it is extremely helpful if any walkway or paths can be given?Define Edges
- 31Where open spaces are provided, The blind can become particularly disoriented. Therefore, it is extremely helpful if any walkway or paths can be given define edges either by the use of__________, ___________, which provide a texture difference from path?* Planters with draft walls
* Planters with grass verge - 32International Symbols for Access should be use to?* Designate Routes
* Designate Facilities that are accessible - 33Draw Sign A and Name it?Access Symbol
https://www.facebook.com/photo.php?fbid=939900086156774&set=a.189493181197472.65162.100004103741850&type=3&theater - 34Draw Sign B and Name it?Phone
https://www.facebook.com/photo.php?fbid=939901612823288&set=a.189493181197472.65162.100004103741850&type=3&theater - 35Draw Sign C and Name it?Elevator
https://www.facebook.com/photo.php?fbid=939905592822890&set=a.189493181197472.65162.100004103741850&type=3&theater - 36Draw Sign D and Name it?Parking
https://www.facebook.com/photo.php?fbid=939908799489236&set=a.189493181197472.65162.100004103741850&type=3&theater - 37Draw Sign E and Name it?Ramp
https://www.facebook.com/photo.php?fbid=939910879489028&set=a.189493181197472.65162.100004103741850&type=3&theater - 38Draw Sign F and Name it?Pedestrian Suitable for
Disabled
https://www.facebook.com/photo.php?fbid=939914282822021&set=a.189493181197472.65162.100004103741850&type=3&theater - 39Signage Background Color?Blue
- 40Signage Symbols & Figure?White
- 41What Sign Type is “Access Symbol”?Sign Type A
- 42What Sign Type is “Phone”?Sign Type B
- 43What Sign Type is “Elevator”?Sign Type C
- 44What Sign Type is “Parking”?Sign Type D
- 45What Sign Type is “Ramp”?Sign Type E
- 46What Sign Type is “Pedestrian Suitable for Disabled”?Sign Type F
- 47Sign "A" Dimension?10cm X 10cm
- 48Sign A,B,C,D Dimension?15cm X 15cm
- 49Sign A,B,C, Dimension?22cm X 22cm
- 50Sign A,B,C,D,E Dimension?Either 30cm X 30cm or 60cm X 60cm
- 51Sign F Dimension?20cm X 60cm
- 52Sign A 10cm X 10cm Usage?Comfort Room Stall doors
- 53Sign A,B,C,D 15cm X15cm Usage?With or Without Directional Arrows
to Identify doors, Room
ALE - 54Sign A,B,C, 22cm X 22cm Usage?With or Without Arrows
- 55Sign A,B,C,D,E Either 30cm X 30cm or 60cm X 60cm Usage?For Exterior Use
- 56Sign F Usage?For Exterior Use
- 57Should a Sign Portrude into a Sidewalk or Route. A Minimum Headroom is?2.00 Meter
- 58Sign on walls and Doors should be Located at a Maximum Height of?1.60 Meter
- 59Sign on walls and Doors should be Located at a Minimum Height of?1.40 Meter
- 60Signages Labeling public rooms and places should have raised symbols, letters or numbers with a minimum height of?1mm
- 61If the carriageway to be exceeds 10.00 Meter. Therefore, In order to reduce the exposure time to vehicular traffic, have central refuges of at least how many meter?1.50 Meter Width
- 62If the carriageway to be exceeds 10.00 Meter. Therefore, In order to reduce the exposure time to vehicular traffic, have central refuges preferably how many meter?2.00 Meter Width
- 63How many meter the carriageway is long enough to be crossed before considering central refuges island?More than 10.00 Meter
- 64What Materials to be Provide in the Immediate Vicinity of Crossings as an aid to the Blind?Tactile Blocks
- 65Crossings with pedestrian phases and audible signals are most beneficial to the disabled; they should provided where ever possible?Light Controlled
- 66It is used for crossings to easily distinguishable from other sounds in the environment to prevent confusion to the blind.Audible Signals
- 67Sufficient time should be allowed for the slower persons negotiating a crossing; rather than 1.20 m/sec, It should be how many m/sec Walking Speed or Crossing Speed?0.90 m/sec
- 68Sufficient time should be allowed for the slower persons negotiating a crossing; a minimum crossing period should be?6.0 Seconds
- 69Six (6) Parking Space for PWD should be consider?(1) Provide Enough Space for disabled to transfer to a wheel chair from a vehicle.
(2) Parking Space should be near at entrance.
(3) It Recommend parking space should be perpendicular to the road.
(4) Provide Dropped curbs or curb cut-out for termination of floor level.
(5) Pavement Markings & Sign shall be provided to delineate parking spaces - 70Accessible Parking Slot should have a Minimum Width of?3.70 Meter
- 71Regarding PWD Parking. In Between the front ends of Parked Cars That is a Walkway from accessible space of How Many Clear Width?1.20 Meter
- 72Three (3) PWD Consideration for Entrances to building?(1) At least one (1) entrance to be provide both for arrival and departure
to the interior lobby.
(2) One (1) entrance level where elevator are accessible.
(3) Ramps should be provided access to the entrance level in case of
different level. - 73Regarding PWD Entrance. Entrances with Vestibule shal be provided a level area with at least how many dimension?1.80m in Depth & 1.50m in Width
- 74Changes in Level require a ramp except when served by?* Dropped Curb
* Elevator - 75Ramps shall have a minimum clear width of?1.20 Meter
- 76Ramps maximum gradient shall be?1:12
- 77If the ramp gradient is 1:12, What should be the maximum length of one (1) fligth?6.00 Meter
- 78Longer Ramps whose gradient is 1:12 shall be provided with landing not less than how many meter?1.50 Meter
- 79At the top and bottom of terminal of any ramp and these should be level area that require atleast a dimension of?1.80 Meter
- 80Ramps shall be equipped with curbs on both sides with a minimum height of?0.10 Meter
- 81It is neccessary to provide railing where ramp lead down toward vehicular traffic when the rise of ramp enough to consider greater hight at how much steep?More than 0.20 Meter
- 82Any Ramp with a rise greater than 0.20m and leads down towards an area where vehicular traffic is possible, should have a railing of full width of how much width?1.80 Meter
- 83Regarding PWD, All Doors Shall have a minimum clear width of ?0.80 Meter
- 84In Bp344. Doors should be operable by a pressure or force not more than?4.0 kg
- 85In Bp344. For doors, the closing device pressure an interior door shall not exceed?1.0kg
- 86In Bp344 @ doors. A minimum clear level space shall be provided before and extending beyond a door, what is the measure of this space?1.50m X 1.50m
- 87In Bp344 where there is excemption, where a door shall open onto but not into corridor, the required clear, level space on the corridor side of the door may be a minimum of corridor width?1.20 Meter
- 88In Bp344, Doors Knobs and other hardware should be located between from_______, above the floor?0.82 Meter
- 89In Bp344, Doors Knobs and other hardware should be located between to_______, above the floor?1.06 Meter
- 90In Bp344, Preferred height of a door knob?0.90 Meter
- 91In Bp344, Preferred height for Vertical pull handles and horizontall pull bars?1.06 Meter
- 92In Bp 344, Doors along major circulation routes should be provided with kick plates made of durable materials at a height of?0.30m to 0.40m
- 93In Bp 344, Thresholds and sliding door tracks shall have a maximum height of ________ and preferably ramp?25mm
- 94In Bp 344, Manual switches shall be positioned within at how much meter from above the floor?1.20m to 1.30m
- 95In Bp344, Manual Switches should be located no further than how many meter from the latch side of the door?0.20 Meter
- 96In Bp344, Corridors shall have a minimum clear width of?1.20 Meter
- 97In Bp344, Recesses or Turnabout spaces should be provided for wheel chairs to turn around or to enable another wheelchair to pass; these spaces shall have a minimum area of?1.50m X 1.50m
- 98In Bp344, Recesses or Turnabout spaces should be provided for wheel chairs to turn around or to enable another wheelchair to pass; these spaces shall have a minimum area of 1.50m X 1.50m and shall be space at a maximum of?12 Meter
- 99In Bp344, Turnabout spaces should also be provided at or within ______ of every dead end?3.50 Meter
- 100In Bp344, Accessible water closet stalls have a minimum area of?1.70m X 1.80m
- 101In BP344, What is the Turning space area for wheel chair shall be provided into water closets stalls?2.25 sq.m
- 102In Bp344, What is the minimum dimension for a turning space area by wheel chair provided for water closet stalls for lateral mounting?1.50 Meter
- 103The Minimum number of Accessible Water Closets on each floor level or on that part of a floor level accessibled to the disabled shall be how many water closet?One (1) Water Closet
- 104In bp344, One (1) Water Closet is determined by how many set?20 Sets
- 105In bp344, Two (2) Water Closet is given if the set is?More than 20 Sets